GB 4789.2-2022 PDF English
US$105.00 · In stock · Download in 9 secondsGB 4789.2-2022: National food safety standard - Microbiological examination of food: Aerobic plate count Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid GB 4789.2: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
GB 4789.2-2022 | English | 105 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard - Microbiological examination of food: Aerobic plate count
| Valid |
GB 4789.2-2016 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard -- Food microbiological examination -- Aerobic plate count
| Obsolete |
GB 4789.2-2010 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard -- Food microbiological examination: Aerobic plate count
| Obsolete |
GB/T 4789.2-2008 | English | 319 |
Add to Cart
|
3 days
|
Microbiological examination of food hygiene -- Aerobic plate count
| Obsolete |
GB/T 4789.2-2003 | English | 199 |
Add to Cart
|
2 days
|
Microbiological examination of food hygiene -- Detection of aerobic bacterial count
| Obsolete |
GB 4789.2-1994 | English | RFQ |
ASK
|
3 days
|
Microbiological examination of food hygiene. Detection of aerobic bacterial count
| Obsolete |
GB 4789.2-1984 | English | RFQ |
ASK
|
3 days
|
Microbiological examination of food hygiene--Detection of aerobic bacterial count
| Obsolete |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB 4789.2-2022
GB 4789.2-2022: National food safety standard - Microbiological examination of food: Aerobic plate count ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB4789.2-2022
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National food safety standard - Microbiological examination
of food. Aerobic plate count
Issued on. JUNE 30, 2022
Implemented on. DECEMBER 30, 2022
Issued by. National Health Commission of the PRC;
State Administration for Market Regulation.
Table of Contents
Foreword... 3
1 Scope... 4
2 Terms and definitions... 4
3 Equipment and materials... 4
4 Medium and reagents... 5
5 Examination procedure... 5
6 Operation steps... 6
7 Result and report... 8
Appendix A Medium and reagents... 10
Appendix B Examples... 12
Foreword
This Standard replaces GB 4789.2-2016 "National food safety standard - Food
microbiological examination - Aerobic plate count".
Compared with GB 4789.2-2016, the main changes of this Standard are as follows.
- Add Appendix B;
- Modify the equipment and materials;
- Modify the medium and reagents;
- Modify the examination procedure;
- Modify the operation steps;
- Modify Appendix A.
National food safety standard - Microbiological examination
of food. Aerobic plate count
1 Scope
This Standard specifies the method for the determination of aerobic plate count in food.
This Standard applies to the determination of aerobic plate count in food.
2 Terms and definitions
2.1 Aerobic plate count
The total number of microbiological colonies formed in per g (mL) of test sample,
which is obtained after the food sample under test is processed and cultured under
certain conditions (such as culture medium, culture temperature, and incubation time,
etc.).
3 Equipment and materials
In addition to the routine sterilization and culture equipment in the microbiology
laboratory, other equipment and materials are as follows.
a) Constant-temperature incubator.
b) Refrigerator.
c) Thermostat.
d) Balance. Sensitivity is 0.1 g.
e) Homogenizer.
f) Oscillator.
g) Sterile straw. 1 mL (with 0.01 mL scale), 10 mL (with 0.1 mL scale) or
micropipette and tip.
h) Sterile conical flask. Capacity is 250 mL and 500 mL.
i) Sterile petri dish. Diameter is 90 mm.
j) pH meter or pH colorimetric tube or precision pH test paper.
k) Magnifying glass or/and colony counter.
4 Medium and reagents
4.1 Plate count agar medium. See A.1.
4.2 Test piece of aerobic plate count. It shall meet the quality control requirements of
plate count agar medium in GB 4789.28.The main nutrients are consistent with the
formula of plate count agar medium.
4.3 Sterile phosphate buffer. See A.2.
5 Examination procedure
The examination procedure for aerobic plate count is shown in Figure 1.
6 Operation steps
6.1 Dilution of sample
6.1.1 Solid and semi-solid sample. Weigh 25 g of sample; place it in a sterile
homogeneous cup filled with 225 mL of sterile phosphate buffer or sterile normal saline.
Homogenize at 8000 r/min~10000 r/min for 1 min~2 min. Or put it into a sterile
homogeneous bag containing 225 mL of diluent. Use a slap-type homogenizer to beat
for 1 min~2 min, to make a 1.10 sample homogenate.
Test sample25 g (mL) of sample + 225 mL of diluent,homogenized10-fold serial dilution
Culture Add 15 mL~20 mL of plate count agar
medium to each dish and mix well Select 1~3 sample homogenates of
appropriate dilution; add 1 mL of each to asterile petri dish Count the number of colonies
on each plate Calculate the aerobic plate count Report Culture at 36 °C±1 °C for 48 h±2 h. Aquatic
products are cultured at 30 °C±1 °C for 72 h±3 h
6.1.2 Liquid sample. Use a sterile straw to pipette 25 mL of sample; place it in a sterile
conical flask containing 225 mL of sterile phosphate buffer or sterile normal saline (an
appropriate number of sterile glass beads can be preset in the bottle); and mix
thoroughly. Or put it into a sterile homogeneous bag containing 225 mL of diluent. Use
a slap-type homogenizer to beat for 1 min~2 min, to make a 1.10 sample homogenate.
When the result is required to be the aerobic plate count per g of sample, operate
according to 6.1.1.
6.1.3 Use a 1 mL sterile straw or micropipette to draw 1 mL of the 1.10 sample
homogenate; along the tube wall, slowly inject it into a sterile test tube containing 9 mL
of diluent (be careful not to touch the surface of the diluent with the pipette or the tip).
Oscillate and mix on an oscillator, to make a 1.100 sample homogenate.
6.1.4 According to the operation in 6.1.3, prepare a 10-fold serial dilution of the sample
homogenate. For each incremental dilution, use a new 1 mL sterile straw or tip.
6.1.5 According to the estimation of the contamination status of sample, select 1 to 3
sample homogenates with appropriate dilution (liquid samples can include stock
solution). Pipette 1 mL of the sample homogenate into a sterile petri dish; make two
petri dishes for each degree of dilution. At the same time, respectively pipette 1 mL of
blank diluent; add it to two sterile petri dishes as blank control.
6.1.6 In a timely manner, pour 15 mL~20 mL of plate count agar medium cooled to
46 °C~50 °C (which can be kept in a thermostat at 48 °C±2 °C) into a petri dish; rotate
the petri dish to make it evenly mixed.
6.2 Culture
6.2.1 Place horizontally until the agar solidifies; turn the plate over; incubate at
36 °C±1 °C for 48 h±2 h. Aquatic products are cultured at 30 °C±1 °C for 72 h±3 h. If
the sample may contain colonies that spread and grow on the surface of the agar
medium, it is possible to cover the surface of the solidified agar medium with a thin
layer of plate count agar medium (about 4 mL). After solidification, turn the plate over
and culture.
6.2.2 If the test piece of aerobic plate count is used, it shall be operated in accordance
with the relevant technical regulations provided for the test piece.
6.3 Colony count
6.3.3 When one of the plates has larger flaky colonies, it is not suitable to use it. The
plate without larger flaky colonies shall be used as the colony count of the degree of
dilution. If the flaky colonies are less than half of the plate, and the colonies in the
remaining half are evenly distributed, it is possible to calculate the number of the half
plate and multiply it by 2, to represent the number of colonies on one plate.
6.3.4 When there is a chain growth with no clear boundary between the colonies on the
plate, count each single chain as a colony.
7 Result and report
7.1 Calculation method of aerobic plate count
7.1.1 If the number of colonies on only one dilution plate is within the appropriate count
range, calculate the average of the number of colonies on the two plates; then multiply
the average by the corresponding dilution factor as the aerobic plate count per g (mL)
of the sample. Example is given in B.1.
7.1.2 If the number of colonies on the plate with two serial dilutions is within the
appropriate count range, calculate according to formula (1). For an example, see B.2.
Where.
7.1.3 If the number of colonies on all dilution plates is greater than 300 CFU, the plate
with the highest dilution shall be counted. The other plates can be recorded as
uncountable. The result shall be calculated by multiplying the average number of
colonies by the highest dilution ratio. For an example, see B.3.
7.1.4 If the plate colony count of all dilutions is less than 30 CFU, it shall be calculated
by multiplying the average colony count with the lowest dilution by the dilution ratio.
For an example, see B.4.
7.1.5 If plates at all degrees of dilution (including liquid sample stock solution) have no
colony growth, it shall be calculated by multiplying less than 1 by the minimum dilution
ratio. For an example, see B.5.
7.1.6 If the number of colonies on the plates at all degrees of dilution is not between 30
CFU and 300 CFU, and some of them are less than 30 CFU or greater than 300 CFU,
it shall be calculated by multiplying the average colony number closest to 30 CFU or
300 CFU by the dilution ratio. For an example, see B.6.
7.2 Report of aerobic plate count
Appendix A
Medium and reagents
A.1 Plate count agar (PCA) medium
A.1.1 Ingredients
Tryptone (main nutrient). 5.0 g
Yeast extract (main nutrient). 2.5 g
Glucose (main nutrient). 1.0 g
Agar. 15.0 g
Distilled water. 1000 mL
A.1.2 Preparation method
Add the above ingredients to distilled water; boil to dissolve; adjust the pH to 7.0±0.2.
Dispense into suitable containers; sterilize by autoclaving at 121 °C for 15 min.
A.2 Sterile phosphate buffer
A.2.1 Ingredients
Potassium dihydrogen phosphate (KH2PO4). 34.0 g
Distilled water. 500 mL
A.2.2 Preparation method
Stock solution. Weigh 34.0 g of potassium dihydrogen phosphate and dissolve it in 500
mL of distilled water; use about 175 mL of 1 mol/L sodium hydroxide solution to adjust
the pH to 7.2; use distilled water to dilute to 1000 mL; store in the refrigerator.
Diluent. Take 1.25 mL of the stock solution; use distilled water to dilute to 1000 mL;
divide it into suitable containers; sterilize it by autoclaving at 121 °C for 15 min.
A.3 Sterile normal saline
A.3.1 Ingredients
Sodium chloride. 8.5 g
Distilled water. 1000 mL
A.3.2 Preparation method
Weigh 8.5 g of sodium chloride; dissolve it in 1000 mL of distilled water; sterilize by
autoclaving at 121 °C for 15 min.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB 4789.2-2022 be delivered?Answer: The full copy PDF of English version of GB 4789.2-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB 4789.2-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB 4789.2-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 4789.2-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds. Question 5: Should I purchase the latest version GB 4789.2-2022?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 4789.2-2022 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
How to buy and download a true PDF of English version of GB 4789.2-2022?A step-by-step guide to download PDF of GB 4789.2-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB 4789.2-2022". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|