HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

YY/T 1193-2011 PDF English

US$110.00 · In stock · Download in 9 seconds
YY/T 1193-2011: Follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay)
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YY/T 1193-2011English110 Add to Cart 0-9 seconds. Auto-delivery Follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay) Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YY/T 1193-2011
      

Similar standards

YY/T 1197   YY/T 1198   YY/T 1192   YY/T 1200   

YY/T 1193-2011: Follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay)


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT1193-2011
YY ICS 11.100 C 44 INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay) Issued on: DECEMBER 31, 2011 Implemented on: JUNE 1, 2013 Issued by. State Food and Drug Administration

Table of Contents

Foreword ... 3 1  Scope ... 4 2  Normative references ... 4 3  Classification ... 4 4  Requirements ... 5 5  Test methods ... 6 6  Marks, labels and instructions ... 9 7  Packaging, transportation and storage ... 11 Bibliography ... 12

Foreword

This standard was drafted in accordance with the rules specified in GB/T 1.1-2009. Please note that some contents in this file may involve patents. The issuing organization of this file does not bear the responsibility to identify these patents. This standard was proposed by the China Food and Drug Administration. This standard shall be under the jurisdiction of the China Clinical Laboratory Testing and In vitro Diagnostic Test System of Standardization Administration of China (SAC/TC 136). Drafting organizations of this standard. Beijing Institute of Medical Device Testing, Beijing Yuande Medical Engineering Co., Ltd., IVD Reagents and Culture Medium Laboratory of National Institute for the Control of Pharmaceutical and Biological Products, Beijing Bio-Ekon Biotechnology Co., Ltd., and Johnson & Johnson Medical (Shanghai) Ltd. The main drafters of this standard. Wang Ruixia, Tang Lei, Huang Ying, Wang Jianming, and Nie Jing. Follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay)

1  Scope

This standard specifies the product classification, requirements, test method, marks, labels, instructions, packaging, transportation and storage etc. of the follicle stimulating hormone (FSH) quantitative immunoassay kit (chemiluminescent immunoassay). This standard is applicable to follicle stimulating hormone (FSH) kit [hereinafter referred as “FSH kit”] of quantitative detection in human blood matrix or other body fluid components, based on the principle of chemiluminescent immunoassay. It includes the enzymatic and non-enzymatic chemiluminescent immunoassay detection kit in the carriers of micro-plates, pipes, magnetic particles, micro-beads and plastic beads. This standard does not apply to. a) The calibrator and quality control product of follicle stimulating hormone intended for separate sale; b) Biochip that uses the principle of chemiluminescent immunoassay. 2  Normative references The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document. GB/T 21415-2008 In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials

3  Classification

FSH kit can be divided into enzymatic and non-enzymatic chemiluminescent immunoassay kits according to different chemiluminescent principles. It can be divided into different kinds of chemiluminescent immunoassay kits taking micro-plates, tubes, magnetic particles, micro-beads and plastic beads as carrier according to the various solid phase carriers. According to different operation processes, it can be divided into manual operation method and instrument-automatic operation method. coefficient r of the kit, within the linear range specified by the manufacturing enterprise, shall not be less than 0.990. 4.7 Repeatability Use the samples with at least 2 concentration levels. Respectively repeat the detection for 10 times. The coefficient of variation (CV) shall not be more than 8.0% (instrument-automatic operation method) or not more than 12.0% (manual operation method). 4.8 Within-batch difference Use 3 batches of kits to detect the same sample. The coefficient of variation (CV) among the 3 kits shall not be more than 15.0%. 4.9 Stability The following methods can be used for verification. a) Stability within the validity. The manufacturing enterprise shall specify the validity of the kit. Take the kit that has been expired to detect the accuracy, minimum detection limit, linearity and repeatability. It shall meet the requirements of 4.3, 4.4, 4.6 and 4.7; b) Thermal stability test. The kit within the period of validity is placed at 37°C for 3d. Test the accuracy, minimum detection limit, linearity and repeatability. It shall meet the requirements of 4.3, 4.4, 4.6 and 4.7. Note 1. Thermal stability test cannot be used to derive the validity of products, unless it uses the derivation formula that is established and based on a large number of stability study data; Note 2. Any arbitrary combination of a) and b) can be selected according to the product characteristics, but the selected method shall be capable of verifying the stability of the product, so as to ensure that the performance of the product can comply with the standard requirements within valid period. 5  Test methods 5.1 Appearance Use the corrected-visual-acuity to visually inspect, under the natural light. It shall meet the requirements of 4.1. 5.2 Traceability Traceability information provided by the manufacturing enterprise shall meet the requirements of 4.2. e) Product batch number; f) Expiration date; g) Storage conditions. 6.2 Marks and labels of each component package of kit It shall contain at least the following contents. a) Product names and packaging specifications; b) Name or trademarks of manufacturers; c) Product batch number; d) Expiration date; e) Storage conditions. 6.3 Instructions of kit It shall include at least the following contents. a) Product name; b) Packaging specifications; c) Intended use; d) Detection principle; e) Main compositions; f) Storage conditions and expiration date; g) Applicable instrument; h) Sample requirement; i) Detection method; j) Reference value (Reference range); k) Explanation of the detection result; l) The limitations of detection methods; m) Product performance index; Bibliography 1. YY/T 0316-2008 Medical devices — Application of risk management to medical devices (ISO 14971. 2007, IDT) 2. YY/T 0466.1-2009 Devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1.General requirements (ISO 15223.1-2009, IDT) 3. GB/T 191-2008 Packaging - Pictorial marking for handling of goods 4. GB/T 9969-2008 General principles for preparation of instructions for use of industrial products ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YY/T 1193-2011 be delivered?

Answer: The full copy PDF of English version of YY/T 1193-2011 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 1193-2011_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1193-2011_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YY/T 1193-2011 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 1193-2011?

A step-by-step guide to download PDF of YY/T 1193-2011_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 1193-2011".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9