YY/T 1155-2019 English PDF (YY/T 1155-2009)

YY/T 1155-2019_English: PDF (YY/T1155-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 1155-2019English245 Add to Cart 0--9 seconds. Auto-delivery Automatic luminescence immunoassay analyzer Valid YY/T 1155-2019
YY/T 1155-2009English120 Add to Cart 0--9 seconds. Auto-delivery Automatic Luminescence Immunoassay Analyzer Obsolete YY/T 1155-2009


BASIC DATA
Standard ID YY/T 1155-2019 (YY/T1155-2019)
Description (Translated English) Automatic luminescence immunoassay analyzer
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.100
Word Count Estimation 14,185
Date of Issue 2019
Date of Implementation 2020-06-01
Summary This standard specifies the requirements, test methods, labeling, marking and instructions for use, packaging, transportation and storage of fully automatic luminescence immunoassay analyzers. This standard applies to automatic luminescence immunoassay analyzers (hereinafter referred to as analyzers) used in medical laboratories. The analyzer adopts luminescence system and immunoassay method to quantitatively or qualitatively detect various analytes in human serum, plasma or other body fluids, including luminescence immunoassay analyzers based on the principles of chemiluminescence, electrochemiluminescence, and fluorescence. This standard does not apply to: luminescence immunoassay analyzer based on image recognition; automatic luminescence immunoassay analyzer for point-of-care testing (POCT).

BASIC DATA
Standard ID YY/T 1155-2009 (YY/T1155-2009)
Description (Translated English) Automatic Luminescence Immunoassay Analyzer
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C44
Classification of International Standard 11.100
Word Count Estimation 8,869
Date of Issue 2009-12-30
Date of Implementation 2011-06-01
Quoted Standard GB/T 191; GB/T 14710; GB 4793.1-2007; YY 0466-2003
Drafting Organization Beijing Medical Device Testing
Administrative Organization National Standardization Technical Committee of Medical clinical testing laboratories and in vitro diagnostic systems
Regulation (derived from) China Food & Drug Administration Announcement 2009 No.83
Summary This standard specifies the fully automated immunoassay analyzer requirements, test methods, marking, labeling and brochures, packaging, transport and storage of materials. This standard applies to automated immunoassay analyzer (hereinafter referred to as the analyzer). Analyzer using luminescence immunoassay systems and methods of human serum, plasma or other body fluids of various analytes quantitative and qualitative detection, including those based on chemiluminescence, electrochemiluminescence, such as the principle of fluorescence immunoassay analyzer.


YY/T 1155-2019 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA ICS 11.100 C 44 Replacing YY/T 1155-2009 Automatic luminescence immunoassay analyzer ISSUED ON: MAY 31, 2019 IMPLEMENTED ON: JUNE 1, 2020 Issued by: National Medical Products Administration Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Requirements ... 6 5 Test methods ... 9 6 Labels, markings, and instructions for use ... 15 7 Packaging, transportation, and storage ... 15 Appendix A (Informative) Densities of pure water at different temperatures under standard atmospheric pressure ... 16 References ... 17 Automatic luminescence immunoassay analyzer 1 Scope This standard specifies the requirements, test methods, labels, markings and instructions for use, packaging, transportation, and storage of automatic luminescence immunoassay analyzers. This standard applies to automatic luminescence immunoassay analyzers (hereinafter referred to as analyzers) used in medical laboratories. Analyzers use luminescent systems and immunoassay methods to quantitatively or qualitatively detect various analytes in human serum, plasma, or other body fluids, including luminescence immunoassay analyzers based on chemiluminescence, electrochemiluminescence, fluorescence, and other principles. This standard does not apply to luminescence immunoassay analyzers based on image recognition and automatic luminescence immunoassay analyzers for point-of-care testing (POCT). 2 Normative references The following documents are essential for the application of this document. For any referenced document with a date, only the version with the date applies to this document. For any referenced document without a date, the latest version (including all amendments) applies to this document. GB/T 191 Packaging - Pictorial marking for handling of goods GB 4793.1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements GB 4793.6 Safety requirements for electrical for measurement, control, and laboratory use - Part 6: Particular requirements for laboratory equipment for the heating of materials GB 4793.9 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 9: Particular requirements for automatic and semi- automatic laboratory equipment for analysis and other purposes GB/T 14710 Environmental requirement and test methods for medical electrical equipment GB/T 18268.1 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements GB/T 18268.26 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 26: Particular requirements - In vitro diagnostic (IVD) medical equipment GB/T 29791.3 In vitro diagnostic medical devices - Information supplied by the manufacturer (labelling) - Part 3: In vitro diagnostic instruments for professional use YY 0648 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment 3 Terms and definitions The following terms and definitions apply to this document. 3.1 luminescence immunoassay A method that combines a luminescent system with an immune response to detect antigens or antibodies. 3.2 luminescence immunoassay analyzer Immunoassay analyzers that are based on luminescent immunoassay technology and can perform qualitative or quantitative testing. 3.3 automatic luminescence immunoassay analyzer A luminescence immunoassay analyzer by which all analytical processes including the injection of samples and reagents, the provision of the immune binding reaction environment, data measurement, result calculation and output are implemented automatically. 4 Requirements 4.1 Accuracy and repeatability of sample addition The minimum and maximum sample loading volumes and the minimum and maximum reagent loading volumes specified on the instrument shall be tested and shall comply with the requirements of Table 1. Select at least one clinical item and conduct the intra-batch precision test using the calibrators and kits specified by the manufacturer. The intra-batch precision shall comply with the requirements of the corresponding national standards and industry standards. If there are no national standards or industry standards, it shall comply with the manufacturer's specifications. 4.6 Main functions of the analyzer The analyzer shall have the following main functions: a) Users can use human-computer dialogue instructions to enable the instrument to automatically complete the analysis tasks of different samples and test items; b) The instrument shall be able to indicate the status of consumables such as reagents and waste; c) The instrument has a self-checking function; d) Fault prompts: The instrument shall have corresponding prompts for operating errors, and mechanical and circuit failures. 4.7 Appearance The appearance of the analyzer shall meet the following requirements: a) The appearance shall be neat, without cracks or scratches, and the text and logos shall be clear; b) The moving parts of the analysis system shall be stable and shall not get stuck or jump; c) Fastener connections shall be firm and reliable without any looseness. 4.8 Environmental test requirements It shall meet the requirements of climate environment group I and mechanical environment group I in GB/T 14710. 4.9 Security requirements It shall comply with the requirements of applicable clauses in GB 4793.1, GB 4793.6, GB 4793.9, and YY 0648. 4.10 Electromagnetic compatibility requirements It shall comply with the applicable provisions of GB/T 18268.1 and GB/T 18268.26. 5 Test methods 5.1 Normal working environment conditions 5.1.1 Power supply voltage: 220 V±22 V; 50 Hz±1 Hz; 5.1.2 Ambient temperature: 10 ℃~30 ℃; 5.1.3 Relative humidity: 30%~70%; 5.1.4 Atmospheric pressure: 85.0 kPa~106.0 kPa; 5.1.5 Stay away from strong electromagnetic interference; 5.1.6 Avoid direct exposure to strong light; 5.1.7 There is a good grounding environment. NOTE: When the conditions in 5.1.2~5.1.4 are inconsistent with the manufacturer's specifications, the manufacturer's specifications shall prevail. The manufacturer shall specify them in the product technical requirements. 5.2 Accuracy and repeatability of sample addition There are two types of determination methods: colorimetry and weighing method. Manufacturers can choose either method. 5.2.1 Weighing method The weighing method is carried out according to the following steps: a) Place the analyzer, degassed pure water, etc. in a constant temperature and humidity laboratory for several hours before starting the test. Prepare a suitable container (to prevent the water in the container from evaporating) and adjust the zero value on an electronic balance with a graduation value of 0.01 mg; b) Place the container in a suitable position, control the reagent needle or sample needle to add a specified amount of degassed pure water into the container, and then weigh its mass on the electronic balance; c) Repeat the measurement 20 times for each specified addition amount. The actual addition amount each time is equal to the mass of the degassed pure water added divided by the density of pure water at the current temperature. The density of pure water at different temperatures can be found in Appendix A. Calculate the actual value vi of each addition and calculate the average value ̅; The test can be carried out by the luminescent agent method or the reference light source method. Use the analyzer and the reference light source or luminescent agent at two levels, high and low, within the linear range to test. Test 10 times in a row and record the luminescence values. Calculate the standard deviation and coefficient of variation of the luminescence values. The coefficient of variation shall comply with the provisions of 4.3.3. 5.4.4 Stability of luminescence value The test can be carried out by the luminescent agent method or the reference light source method. After the analyzer is turned on and in a stable working state, use the reference light source or luminescent agent at two levels, high and low, within the linear range to test; repeat the test three times, record the luminescence values, and calculate the average value I0 of the measurement results. After 4 hours and 8 hours, repeat the test three times on the machine respectively, and calculate the average values I1 and I2 of the measurement results; take I0 as the reference value, and calculate the relative bias (α) according to formula (6), which shall meet the requirements of 4.3.4. where: α -- the relative bias of luminescence values; Ii -- the measured values at 4 h and 8 h; I0 -- initial measurement value. 5.5 Carryover The test is carried out as follows: a) The manufacturer specifies the clinical test item; b) Prepare a high-concentration sample (Iprimary) for the clinical test item; the concentration of the high-concentration sample shall be at least 105 times the detection limit of the detection system; NOTE: If the detection system cannot accurately detect high-concentration samples due to limitations in the measurement range of the analyzer or reagents, the dilution extrapolation method can be used. c) Use the reagents for the clinical test item specified by the manufacturer, take high-concentration samples and zero-concentration samples as samples, and test them on the analyzer in the order of high-concentration sample, high- concentration sample, high-concentration sample, zero-concentration sample, zero-concentration sample, and zero-concentration sample as a group; carry out a total of 5 groups of such tests; d) In each group of tests, the test value of the 4th sample is I4, and the test value of the 6th sample is I6; e) Calculate the carryover K of each group according to formula (7); f) The carryover of the five groups shall all comply with the provisions of 4.4. For analyzers that can only perform qualitative testing, it is not necessary to calculate K, and I4, I5, and I6 are required to comply with the provisions of 4.4. 5.6 Intra-batch precision of clinical items Using calibrators and kits for the clinical test item specified by the manufacturer, test the intra-batch precision in accordance with the corresponding national standards, industry standards, or test kit technical requirements, which shall comply with the provisions of 4.5. 5.7 Main functions of the analyzer The verification is performed according to the instructions; the functions shall meet the requirements of 4.6. 5.8 Appearance Visual inspection is carried out; the appearance shall comply with the requirements of 4.7. 5.9 Environmental test requirements The test is carried out according to the method specified in GB/T 14710. The results shall meet the requirements of 4.8. 5.10 Security requirements The test is carried out according to the methods specified in GB 4793.1, GB 4793.6, GB 4793.9, and YY 0648, and the results shall meet the requirements of 4.9. 5.11 Electromagnetic compatibility The test is carried out according to the methods specified in GB/T 18268.1 and GB/T 18268.26. The results shall comply with the requirements of 4.10. Iprimary ......


YY/T 1155-2009 YY ICS 11.100 C 44 PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Automatic Luminescence Immunoassay Analyzer ISSUED ON. DECEMBER 30, 2009 IMPLEMENTED ON. JUNE 1, 2011 Issued by. State Food and Drug Administration Table of Contents Foreword ... 3  1  Scope ... 4  2  Normative references ... 4  3  Terms and definitions ... 4  4  Requirements ... 5  5  Test methods ... 6  6  Marks, labels and instructions ... 10  7  Packaging, transportation and storage ... 11  Foreword  The Standard was proposed by China Food and Drug Administration. The Standard shall be under the jurisdiction of National Technical Committee (SAC/TC 136) on System of Medical Clinical Test Lab and in Vitro Diagnostic System of Standardization Administration of China. Drafting organization of this Standard. Beijing Institute of Medical Device Testing, Abbott Laboratories Ltd, Johnson & Johnson Medical (China) Ltd, Roche Diagnostics (Shanghai) Limited, and Beckman Coulter Commercial Enterprise (China) Co., Ltd. The main drafters of this Standard. Wang Jun, Wang Xuefeng, Zhang Zhang, Cai Xiaorong, Zhang Jinwen, and Zhang Xinmei. Automatic Luminescence Immunoassay Analyzer 1  Scope  This Standard specifies the requirements, test methods, marks, labels and instructions, packaging, transportation, and storage of automatic luminescence immunoassay analyzer. This Standard applies to automatic luminescence immunoassay analyzer (hereinafter referred to as “the Analyzer”). The Analyzer uses luminescent system and immunological analyzing method to set and qualitatively detect human blood serum, plasma or other body fluids in a variety of analytes, including luminescent immunoassay analyzers based on principle of chemiluminescence, electrochemical luminescence, fluorescence, etc. 2  Normative references  The articles contained in the following documents have become part of this Standard when they are quoted herein. For the dated documents so quoted, all the modifications (excluding corrections) or revisions made thereafter shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall be applicable to this Standard. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 14710 Environmental requirement and test methods for medical electrical equipment GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1. General requirements (IEC 61010-1. 2001, IDT) YY 0466-2003 Medical devices - Symbols to be used with medical device labels labelling and information to be supplied (ISO 15223. 2000, IDT) 3  Terms and definitions  For the purpose of this Standard, the following terms and definitions apply. 3.1 Luminescence immunoassay It refers to the method to detect antigen or antibody, by combining luminescent system The Analyzer shall be equipped with the following main functions. a) Through the man-machine interactive instructions, users can make the instrument to automatically complete the analytical tasks of different samples and test items; b) The instrument shall be able to present the state of consumables and wastes such as reagents; c) The instrument is equipped with a self-checking function; d) Fault prompt. The instrument shall have corresponding prompts for the operation mistake, mechanical and electrical faults. 4.7 Appearance The appearance shall meet the following requirements. a) The appearance shall be clean and free of cracks or scratches, with clear words and marks; b) The moving parts of analysis system shall be smooth and shall not be stuck or jumped; c) Fasteners shall be connected firmly and reliably. It must not be loosen. 4.8 Safety requirements It shall comply with the requirements of GB 4793.1-2007. 4.9 Requirements of environmental test The environmental test shall meet the following requirements. a) The climatic environment test shall comply with the provisions of Group I for climatic environment test in GB/T 14710; b) The mechanical environment test shall comply with the provisions of Group I for mechanical environment test in GB/T 14710. 5  Test methods  5.1 Normal working environment conditions 5.1.1 Power supply voltage. 220 V ± 22 V, 50 Hz ± 1 Hz; 5.1.2 Environment temperature. 10°C-30°C; 5.1.3 Relative humidity. ≤70%; 5.11 Requirements of environmental test The test shall be conducted in accordance with the method specified in GB/T 14710. 6  Marks, labels and instructions  The symbols used in the labels, marks and instructions of the Analyzer shall comply with the requirements of YY 0466-2003. 6.1 Marks and labels 6.1.1 Outer marks Outer marks, including the nameplate, of the instrument shall mark. a) Name, model / trademark of the product; b) Power supply conditions. c) Ex-factory serial number and date; d) Name of manufacturing enterprise. 6.1.2 Outer packaging The external packaging of the instrument shall mark. a) Name, model / trademark of the product; b) Size and weight; c) Ex-factory serial number or date; d) Transportation and storage marks. Graphic marks shall comply with provisions of GB/T 191; e) The allowable environmental conditions for transportation and storage; f) Name and address of manufacturing enterprise. 6.2 Instructions The instructions, including operating instructions and technical specifications, shall comply with relevant requirements of GB 4793.1-2007 for the instructions. 7  Packaging, transportation and storage  7.1 Packaging Product packaging shall comply with the following requirements. a) Accessories and accompanying documents shall be accompanied with the product and placed in the corresponding independent package; b) The external packing box shall be able to ensure that products are free of mechanical and natural damages; c) The accompanying documents shall include the product specifications and packing list; d) The outer of packing box shall mark the marks specified by GB/T 191. 7.2 Transportation Transportation shall be in accordance with the requirements specified in the Order Contract. 7.3 Storage Packaged analyzer shall be stored at the environment at -40°C-55°C, relative humidity not more than 70%, without corrosive gases, and with ventilated conditions (when storage conditions are not consistent with manufacturing enterprise’s nominal values, product’s nominal values shall prevail. Manufacturing enterprise shall specify in the product standard). ......