Chinese Standards Shop Partner of Google-Books Database: 169760 (Jul 20, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

YY/T 0891-2013

Search Result of Chinese Standard: 'YY/T 0891-2013'
  Full-PDF will be auto-immediately sent (0~15 minutes)  
Detail Information of YY/T 0891-2013; YY/T0891-2013
Description (Translated English): Particular specifications for angiographic injector
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 8,848
Quoted Standard: GB 9706.1-2007; GB 9706.15-2008; GB/T 10149-1988; GB/T 14710-2009
Drafting Organization: Liaoning Province Medical Device Testing
Administrative Organization: National Standardization Technical Committee medical electrical equipment and medical X-ray equipment Standardization Technical Committee
Regulation (derived from): State Food and Drug Administration Notice No. 36 of 2013; industry standard for filing Notice 2013 No. 12 (No. 168 overall)
Proposing organization: State Food and Drug Administration
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies the angiographic high-pressure injection system (hereinafter referred to as "high-pressure injection device") terms and definitions, composition, requirements and test methods. This standard applies to the high-pressure injection d

YY/T 0891-2013
Particular specifications for angiographic injector
ICS 11.040.50
C43
Pharmaceutical industry standards People's Republic of China
Conditions for special high-pressure injection apparatus angiography
Published 2013-10-21
2014-10-01 implementation
China Food and Drug Administration issued
Foreword
This standard was drafted in accordance with rules GB/T 1.1-2009 given.
Please note that some of the content of this document may involve patents. Distribution of this document
Institutions do not assume responsibility to identify these patents.
The standard proposed by the State Administration of Food and Drug Administration.
This standard by the National Medical X-ray apparatus for medical appliances and utensils Standardization Committee Standardization Technical Committee (SAC/TC10/SC1) centralized.
This standard was drafted: Medical Device Testing Liaoning Province, Shenzhen City letter crown Electrical Co., Ltd., Shenzhen Anke High-tech Co., Ltd.
This standard drafter: Jinyu Bo, Su tripods, silver Hyperion.
Conditions for special high-pressure injection apparatus angiography
1 Scope
This standard specifies the angiographic high-pressure injection apparatus (hereinafter referred to as "high-pressure injection apparatus") Terms and Definitions, composition, requirements and test methods.
This standard applies to the high-pressure injection device angiography.
2 Normative references
The following documents for the application of this document is essential. All the reference documents date, only the edition is applicable to this document.
For undated references, the latest edition (including any amendments) applies to this document.
GB 9706.1-2007 Medical Electrical Equipment Part 1: General requirements for safety
GB 9706.15-2008 Medical Electrical Equipment Part 1: General requirements for safety Collateral Standard: Safety requirements for medical electrical systems
GB/T 10149-1988 medical X-ray equipment terms and symbols
GB/T 14710-2009 medical electrical environmental requirements and test methods
3 Terms and Definitions
GB/T 10149 defines the following terms and definitions apply to this document.
3.1
Angiography high-pressure injection apparatus angiographicinjector
In the diagnosis or treatment of vascular interventional angiography, in order to obtain the required medical imaging, angiography with X-ray equipment, to a certain time
Between the high-pressure injection device a sufficient amount of a contrast agent bolus to the inspection site.
Related standard:   YY/T 0887-2013  YY/T 0888-2013
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2019