YY/T 0888-2013 English PDF

YY/T 0888-2013 (YY/T0888-2013, YYT 0888-2013, YYT0888-2013)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0888-2013English110 Add to Cart 0--9 seconds. Auto-delivery Imaging dose of X-ray image-guided devices used in radiotherapy equipment Valid YY/T 0888-2013
Preview PDF: YY/T 0888-2013

BASIC DATA
Standard ID YY/T 0888-2013 (YY/T0888-2013)
Description (Translated English) Imaging dose of X-ray image-guided devices used in radiotherapy equipment
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C43
Classification of International Standard 11.040.60
Word Count Estimation 6,655
Quoted Standard GB 9706.5-2008; GB/T 17857-1999
Drafting Organization Beijing Medical Device Testing
Administrative Organization National Technical Committee of Standardization for medical electrical radiation therapy, nuclear medicine and radiation Standardization Technical Committee dosimetry equipment
Regulation (derived from) State Food and Drug Administration Notice No. 36 of 2013; industry standard for filing Notice 2013 No. 12 (No. 168 overall)
Proposing organization State Food and Drug Administration
Issuing agency(ies) State Food and Drug Administration
Summary This standard specifies: X -ray radiation therapy devices for image-guided device imaging dose test methods and random files requirements. This standard applies to: X -ray radiation therapy devices for image-guided devices.


YY/T 0888-2013 YY ICS 11.040.60 C 43 PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Imaging dose of X-ray image-guided devices used in radiotherapy equipment ISSUED ON. OCTOBER 21, 2013 IMPLEMENTED ON. OCTOBER 1, 2014 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 4  4 General requirements ... 6  5 Description of CTGD imaging dose using kV-level X-ray source ... 6  6 Description of CTGD imaging dose using MV-level X-ray source ... 8  Foreword This Standard was drafted in accordance with the provisions given in the GB/T 1.1-2009. Please pay attention that some contents in this document might involve patents. The issuing authority of this document does not undertake the responsibility for the identification of these patents. This Standard was proposed by China Food and Drug Administration. This Standard shall be under the jurisdiction of the Technical Sub-committee of the Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry of the National Technical Committee for Standardization of Medical Electrical Equipment (SAC/TC 10/SC 3). Drafting organizations of this Standard. Beijing Institute of Medical Device Testing, and Cancer Hospital Chinese Academy of Medical Sciences. Main drafters of this Standard. Zhang Xin, Dai Jianrong, and Yan Xu. Imaging dose of X-ray image-guided devices used in radiotherapy equipment 1 Scope This Standard specifies the test methods for the imaging dose of X-ray image- guided devices used in radiotherapy equipment, and the requirements for the accompanying file. This Standard applies to the X-ray image-guided devices used in radiotherapy equipment. 2 Normative references The following documents are essential to the application of this document. For dated references, only the versions with the dates indicated are applicable to this document. For undated references, only the latest versions (including all the amendments) are applicable to this document. GB 9706.5-2008 Medical electrical equipment – Part 2. Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV GB/T 17857-1999 Medical radiology – Terminology (Equipment for radiotherapy, nuclear medicine and radiation dosimetry) 3 Terms and definitions The terms and definitions defined in the GB/T 17857-1999 and the following ones apply to this document. 3.1 Image guided radiotherapy; IGRT It refers to the radiotherapy that the treatment parameters (including the patients’ positions) are adjusted according to various modes of image information, obtained before or during fractionated treatment. 3.2 Computed tomographic guidance device; CTGD The computed tomographic guidance devices refer to the devices that use computed tomography for image guidance in the radiotherapy equipment. the measurement, the insertion pieces which are the same with the phantom materials shall be completely inserted into the holes. 5.2 CTDI100 dose instructions in the accompanying files 5.2.1 For the CTGD devices using kV-level X-ray source in the IGRT equipment, the phantom specified in the Article 5.1 shall be used for obtaining the following dose information. For any CTGD scanning devices, the dose information of each application (such as head, body, etc.) shall be respectively provided in the accompanying files. The dose phantom shall be placed on the treatment beds during the measurement, and the measurement shall be conducted without any additional attenuating materials. The dose phantom shall be placed in the center of the scanning area, and shall be located on the rotation axis of the CTGD scanning device. 5.2.2 For each application, the information that shall be provided in the accompanying files is as follows. 5.2.2.1 The dose phantom specified in the Article 5.1 shall be used under the CTGD operating conditions (shall be the typical values recommended by manufacturers). The CTDI100 values shall be measured on the following locations. a) INSERT the radiation detector into the measuring hole on the phantom center. MOVE the treatment bed along the axis, so as to find out the location of the maximum CTDI100 value, and to obtain the CTDI100(center) for the rotation axis of the phantom. b) INSERT the radiation detector into a certain measuring hole which is 10mm inward the phantom surface along the parallel line of the rotation axis. c) Respectively ROTATE 90°, 180° and 270° along the rotation axis of the phantom from the location of b). The position when the CTDI100 value comes up to the maximum shall be given according to the provisions specified in b) and the shells of scanning devices or other easily identified components of CTGD scanning devices, so as to make convenience for installing and placing the phantom in this direction. d) CTDI100(periphery) refers to the mean value of four CTDI100 values measured around the dose phantom according to the provisions specified in the Articles 5.2.2.1 b) and 5.2.2.1 c). 5.2.2.2 For each selectable CTGD operating condition, the modification of CTDI100(center) values will change the CTDI100 values in the center of the dose phantom. ......