YY/T 0864-2011 English PDF

YY/T 0864-2011_English: PDF (YY/T0864-2011)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY/T 0864-2011English110 Add to Cart 0--9 seconds. Auto-delivery Medical endoscopes - Endoscope functional supply units - Irrigation pump Valid YY/T 0864-2011


BASIC DATA
Standard ID YY/T 0864-2011 (YY/T0864-2011)
Description (Translated English) Medical endoscopes - Endoscope functional supply units - Irrigation pump
Sector / Industry Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard C40
Classification of International Standard 11.040.99
Word Count Estimation 9,933
Date of Issue 2011-12-31
Date of Implementation 2013-06-01
Quoted Standard GB 9706.1-2007; GB 9706.19-2000; GB/T 14233.2-2005; GB/T 14710-2009; GB/T 16886.1-2011; GB/T 16886.5-2003; GB/T 16886.7-2001; GB/T 16886.10-2005; YY 0709-2009
Drafting Organization Hangzhou, the State Food and Drug Administration Medical Device Quality Supervision and Inspection Center
Administrative Organization National Standardization Technical Committee of Medical optics and instruments
Regulation (derived from) State Food and Drug Administration Notice No. 106 of 2011
Proposing organization State Food and Drug Administration
Issuing agency(ies) China Food and Drug Administration
Summary This standard specifies requirements for medical endoscope expansion chamber with a liquid pump (hereinafter referred to as swelling cavity pumps) requirements. This standard applies to the use of endoscopic surgery swelling cavity pumps. The products are used in minimally invasive endoscopic surgery expansion chamber.


YY/T 0864-2011 Translated English of Chinese Standard. YY/T0864‐2011  YY ICS 11.040.99 C 40 INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Medical endoscopes - Endoscope functional supply units - Irrigation pump ISSUED ON. DECEMBER 31, 2011 IMPLEMENTED ON. JUNE 1, 2013 Issued by. State Food and Drug Administration Table of Contents Foreword ... 3  1  Scope ... 4  2  Normative references ... 4  3  Terms and definitions ... 5  4  Requirements ... 5  5  Test methods ... 7  Foreword  This Standard is drafted according to the rules specified in GB/T 1.1-2009 Please note that some contents in this document may involve in patents. The issuing authority of this document will not be responsible to identify these patents. This Standard was proposed by China's State Food and Drug Administration. This Standard shall be under the jurisdiction of National Technical Sub-committee (SAC/TC 103/ SC 1) on Medical Optical and Instrument of Standardization Administration of China. Drafting organizations of this Standard. Hangzhou Medical Equipment Quality Supervision and Inspection Center of State Food and Drug Administration, and Zhejiang Medical Equipment Inspection Center. The main drafting staffs of this standard. Yan Qinglai, Jia Xiaohang, He Tao, Qi Weiming Zhang Qinyuan, and Zheng Jian. Medical endoscopes - Endoscope functional supply units - Irrigation pump 1  Scope  This Standard specifies the requirements for the irrigation pump that is used for medical endoscope. This Standard applies to irrigation pump that is used in endoscope surgery. It is used for the irrigation in the minimally invasive endoscope surgery. 2  Normative references  The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety GB 9706.19-2000 Medical electrical equipment - Part 2. Particular requirements for the safety of endoscopic equipment GB/T 14233.2-2005 Test methods for infusion, transfusion, injection equipment for medical use - Part 2. Biological test methods GB/T 14710-2009 Environmental requirement and test methods for medical electrical equipment GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1. Evaluation and testing within a risk management process GB/T 16886.5-2003 Biological evaluation of medical devices - Part 5. Test for in vitro cytotoxicity GB/T 16886.7-2001 Biological evaluation of medical devices - Part 7. Ethylene oxide sterilization residuals GB/T 16886.10-2005 Biological evaluation of medical devices - Part 10. Tests for irritation and delayed-type hypersensitivity Connect the irrigation pumps with pipelines, and supply water source according to the provisions in the attached information. After the connection between the pipeline outlet and the pressure buffer, connect the hydraulic pressure gauge. Control the power supply of the irrigation pump to maintain it stable at the nominal voltage. This voltage shall be monitored. The voltage stability shall be controlled within ± 2%. After the completion of the starting self-check procedure of the irrigation pump, it shall show that each component works normally. 5.1.2.2.2 Measurement procedure Set the setting pressure limit on the irrigation pump, expressed as ps. If the setting flow of the irrigation pump is adjustable, set the flow of the irrigation pump to the maximum value. Start to inject in liquid. Read the actual pressure on the hydraulic pressure gauge after it is stabilized, expressed as pr. If the setting pressure limit on the irrigation pump is adjustable, ps shall at least take the highest value, medium value, and the lowest value but not less than 3999Pa (30mmHg). Measure 3 times for each test point. Take the average value as the measurement result pr. 5.1.2.3 Results representation The deviation of the pressure limit setting is expressed in the maximum deviation between the actual pressure and the setting pressure limit, expressed as Aps. Relative value is indicated as Aps = (pr - ps) / ps; absolute value is indicated as Aps = pr - ps. The result shall indicate the ps, pr and Aps values, when the ps is respectively the 3 values set in 5.1.2.2.2. 5.1.3 Determination of overvoltage and reduced-pressure function and overpressure alarm function 5.1.3.1 Device 5.1.3.1.1 Hydraulic pressure gauge Same as 5.1.2.1. 5.1.3.1.2 Elastic cysts It can collect liquid, with elasticity. It has 2 interfaces - of which one can be connected to the exit of irrigation pump pipeline; and the other can be connected to the hydraulic pressure gauge to measure the actual hydraulic pressure in the elastic cysts. 5.2.2.1.2 Timer The accuracy shall be within 0.1s. 5.2.2.2 Steps 5.2.2.2.1 Preparatory work Connect the irrigation pumps with pipelines, and supply water source according to the provisions in the attached information. The outlet of the pipeline is connected with the container of measuring liquid volume. Control the power supply of the irrigation pump to maintain it stable at the nominal voltage. This voltage shall be monitored. The voltage stability shall be controlled within ± 2%. After the completion of the starting self-check procedure of the irrigation pump, it shall show that each component works normally. 5.2.2.2.2 Measurement procedure This test is conducted under the state that the end of the pipeline is opened. Set the setting pressure limit on the irrigation pump to the highest value. Set the setting flow on the irrigation pump, expressed as Ls. Start to inject in liquid. Stop the liquid injection after t min. Measure the volume of injected liquid at the pipeline outlet, expressed as V. Obtain the actual flow Lr through calculation by Formula Lr = V/t. If the setting pressure limit of irrigation pump is adjustable, Ls shall at least take the highest value, medium value and the lowest value within the flow range but not less than 50mL/min (0.003m3/h). Measure 3 times for each test point. Take the average value as the measurement result Lr. 5.2.3 Results representation The deviation of the setting flow is expressed in the maximum deviation between the actual flow and the setting flow, expressed as ALs. When the setting flow is ≥100mL / min (0.006m3/h), ALs is expressed in relative value, i.e. ALs = (Lr - Ls)/ Ls. When the he setting flow is < 100mL / min (0.006m3/h), ALs is expressed in absolute value, i.e. ALs=Lr - Ls. The result shall indicate the Ls, Lr and ALS values, when the Ls is respectively the 3 values set in 5.2.2.2.2. 5.3 Test of the pipeline 9706.19-2000. 5.5 Environmental test The mechanical environmental tolerance test shall be conducted according to provisions of Mechanical Environment Group II in GB/T 14710-2009. Climatic environmental tolerance test shall be conducted in accordance with GB/T 14710-2009. ......

Similar standards: YY 0861-2024  YY/T 0862-2023  YY/T 0871-2022  
Similar PDFs (Auto-delivered in 9 seconds): YY/T 0864-2011  YY 0847-2011  YY 0843-2011  YY/T 0842-2011