YY/T 0774-2019 PDF English
US$199.00 · In stock · Download in 9 secondsYY/T 0774-2019: Ultrasound bone sonometers Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid YY/T 0774: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
YY/T 0774-2019 | English | 199 |
Add to Cart
|
3 days
|
Ultrasound bone sonometers
| Valid |
YY 0774-2010 | English | 439 |
Add to Cart
|
3 days
|
Ultrasound bone sonometers
| Obsolete |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: YY/T 0774-2019
YY/T 0774-2019: Ultrasound bone sonometers---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0774-2019
Ultrasound bone sonometers
ICS 11.040.55
C41
People's Republic of China Pharmaceutical Industry Standard
Replacing YY 0774-2010
Ultrasound bone densitometer
Published on.2019-07-24
2021-08-01 implementation
State Drug Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces YY 0774-2010 "ultrasonic bone densitometer". The main technical changes compared with YY 0774-2010 are as follows.
--- Modified the introduction;
--- Revised the scope of the standard (see Chapter 1, Chapter 1 of the.2010 edition);
---Modified the requirements and test methods for ultrasonic sound velocity (SOS) (see 4.2 and 5.3,.2010 editions 4.1.2 and 5.1.2);
---Modified the requirements for broadband ultrasonic attenuation (BUA) (see 4.3, version 4.1.3 of the.2010 edition);
--- Increased the test method for broadband ultrasonic attenuation (BUA) (see 5.4);
--- Removed the definition of T value, Z value (see.2010, 3.5, 3.6);
--- Removed the definition of the function confirmation program (see 3.8 of.2010 edition);
--- Removed the requirements for power supply voltage adaptability (see version 4.2 of.2010);
--- Removed the requirement for continuous working hours (see 4.3 of.2010 edition);
--- Removed the T-value and Z-value parts of the functional requirements (see 4.4.3 of the.2010 edition);
--- Removed the original Appendix A.
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This standard was proposed by the State Drug Administration.
This standard is under the jurisdiction of the National Medical Electrical Equipment Standardization Technical Committee Medical Ultrasound Equipment Subcommittee (SAC/TC10/SC2).
This standard was drafted. Hubei Institute of Medical Device Quality Supervision and Inspection, Hefei University of Technology, Institute of Acoustics, Chinese Academy of Sciences, Liao
Ning Province Medical Device Inspection Institute, Xianyang Kangrongxin Digital Ultrasound System Co., Ltd., Hubei Food and Drug Administration Technical Review
Check the center.
The main drafters of this standard. Jiang Shilin, Wang Zhiwei, Huang Tao, Peng Hu, Niu Fengqi, Zhu Chenggang, Jiao Qiang, Du Wenyang, Ke Hu, Zheng Chichao,
Zhang Anping.
This standard replaces YY 0774-2010.
introduction
Ultrasound bone densitometer uses a special ultrasonic transducer to measure the amplitude of the attenuation through the (soft tissue and) bone, measuring the speed of sound and
Broadband ultrasound attenuation was calculated and the relevant parameters were calculated to evaluate bone density.
Ultrasound bone densitometer
1 Scope
This standard specifies the terms and definitions, requirements and test methods for ultrasonic bone densitometers.
This standard applies to the use of ultrasound principles, by measuring the speed of sound and attenuation characteristics in the bone to evaluate the bone quality of the human body.
Instrument.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 9706.1 Medical electrical equipment - Part 1. General requirements for safety
GB 9706.9 Medical electrical equipment - Part 2-37. Particular requirements for safety of medical ultrasound diagnostic and monitoring equipment
GB/T 14710-2009 Environmental requirements and test methods for medical appliances
GB/T 15261-2008 Method for measuring acoustic properties of ultrasonic-like tissue materials
JJF1001 General Measurement Terms and Definitions
YY/T 0865.1 Ultrasonic hydrophones Part 1. Measurement and characterization of medical ultrasound fields below 40 MHz
YY/T 0939 Ultrasonic Bone Densitometer Broadband Ultrasonic Attenuation (BUA) Test Method
YY/T 1142 Medical Ultrasound Equipment and Probe Frequency Characteristics Test Method
YY/T 1420 Medical Ultrasound Equipment Environmental Requirements and Test Methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Bone minerality bonemineraldensity
The density of minerals in the bone, ie the amount of minerals per unit volume of bone. The bone density in this standard is evaluated by ultrasound parameters.
The unit is milligrams per cubic centimeter (mg/cm3).
Note. Usually referred to as BMD.
3.2
Nominal working frequency nominalacousticworkingfrequency
Ultrasonic operating frequency published by the designer or manufacturer.
The unit is megahertz (MHz).
3.3
Acoustic operating frequency
The arithmetic mean of the corresponding frequencies at 3 dB below the peak in the sound pressure spectrum.
The unit is megahertz (MHz).
Note. Rewrite YY/T 0865.1, 3.3.
YY/T 0774-2019
Ultrasound bone sonometers
ICS 11.040.55
C41
People's Republic of China Pharmaceutical Industry Standard
Replacing YY 0774-2010
Ultrasound bone densitometer
Published on.2019-07-24
2021-08-01 implementation
State Drug Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces YY 0774-2010 "ultrasonic bone densitometer". The main technical changes compared with YY 0774-2010 are as follows.
--- Modified the introduction;
--- Revised the scope of the standard (see Chapter 1, Chapter 1 of the.2010 edition);
---Modified the requirements and test methods for ultrasonic sound velocity (SOS) (see 4.2 and 5.3,.2010 editions 4.1.2 and 5.1.2);
---Modified the requirements for broadband ultrasonic attenuation (BUA) (see 4.3, version 4.1.3 of the.2010 edition);
--- Increased the test method for broadband ultrasonic attenuation (BUA) (see 5.4);
--- Removed the definition of T value, Z value (see.2010, 3.5, 3.6);
--- Removed the definition of the function confirmation program (see 3.8 of.2010 edition);
--- Removed the requirements for power supply voltage adaptability (see version 4.2 of.2010);
--- Removed the requirement for continuous working hours (see 4.3 of.2010 edition);
--- Removed the T-value and Z-value parts of the functional requirements (see 4.4.3 of the.2010 edition);
--- Removed the original Appendix A.
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This standard was proposed by the State Drug Administration.
This standard is under the jurisdiction of the National Medical Electrical Equipment Standardization Technical Committee Medical Ultrasound Equipment Subcommittee (SAC/TC10/SC2).
This standard was drafted. Hubei Institute of Medical Device Quality Supervision and Inspection, Hefei University of Technology, Institute of Acoustics, Chinese Academy of Sciences, Liao
Ning Province Medical Device Inspection Institute, Xianyang Kangrongxin Digital Ultrasound System Co., Ltd., Hubei Food and Drug Administration Technical Review
Check the center.
The main drafters of this standard. Jiang Shilin, Wang Zhiwei, Huang Tao, Peng Hu, Niu Fengqi, Zhu Chenggang, Jiao Qiang, Du Wenyang, Ke Hu, Zheng Chichao,
Zhang Anping.
This standard replaces YY 0774-2010.
introduction
Ultrasound bone densitometer uses a special ultrasonic transducer to measure the amplitude of the attenuation through the (soft tissue and) bone, measuring the speed of sound and
Broadband ultrasound attenuation was calculated and the relevant parameters were calculated to evaluate bone density.
Ultrasound bone densitometer
1 Scope
This standard specifies the terms and definitions, requirements and test methods for ultrasonic bone densitometers.
This standard applies to the use of ultrasound principles, by measuring the speed of sound and attenuation characteristics in the bone to evaluate the bone quality of the human body.
Instrument.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 9706.1 Medical electrical equipment - Part 1. General requirements for safety
GB 9706.9 Medical electrical equipment - Part 2-37. Particular requirements for safety of medical ultrasound diagnostic and monitoring equipment
GB/T 14710-2009 Environmental requirements and test methods for medical appliances
GB/T 15261-2008 Method for measuring acoustic properties of ultrasonic-like tissue materials
JJF1001 General Measurement Terms and Definitions
YY/T 0865.1 Ultrasonic hydrophones Part 1. Measurement and characterization of medical ultrasound fields below 40 MHz
YY/T 0939 Ultrasonic Bone Densitometer Broadband Ultrasonic Attenuation (BUA) Test Method
YY/T 1142 Medical Ultrasound Equipment and Probe Frequency Characteristics Test Method
YY/T 1420 Medical Ultrasound Equipment Environmental Requirements and Test Methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Bone minerality bonemineraldensity
The density of minerals in the bone, ie the amount of minerals per unit volume of bone. The bone density in this standard is evaluated by ultrasound parameters.
The unit is milligrams per cubic centimeter (mg/cm3).
Note. Usually referred to as BMD.
3.2
Nominal working frequency nominalacousticworkingfrequency
Ultrasonic operating frequency published by the designer or manufacturer.
The unit is megahertz (MHz).
3.3
Acoustic operating frequency
The arithmetic mean of the corresponding frequencies at 3 dB below the peak in the sound pressure spectrum.
The unit is megahertz (MHz).
Note. Rewrite YY/T 0865.1, 3.3.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of YY/T 0774-2019 be delivered?Answer: The full copy PDF of English version of YY/T 0774-2019 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of YY/T 0774-2019_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0774-2019_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YY/T 0774-2019 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds. Question 5: Should I purchase the latest version YY/T 0774-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0774-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
How to buy and download a true PDF of English version of YY/T 0774-2019?A step-by-step guide to download PDF of YY/T 0774-2019_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "YY/T 0774-2019". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|