HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (23 Mar 2025)

YY 0285.5-2018 (YY/T 0285.5-2018) English PDF

Search result: YY/T 0285.5-2018 (YY 0285.5-2018 Newer Version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YY 0285.5-2018English145 Add to Cart 0--9 seconds. Auto-delivery Intravascular catheters--Sterile and single-use catheters--Part 5: Over-needle peripheral catheters Obsolete YY 0285.5-2018
YY/T 0285.5-2018English289 Add to Cart 3 days [Need to translate] Intravascular catheters-Sterile and single-use catheters--Part 5: Over-needle peripheral catheters Valid YY/T 0285.5-2018
YY 0285.5-2004English559 Add to Cart 3 days [Need to translate] Sterile, single-use intravascular catheters. Part 5: Over-needle peripheral catheters Obsolete YY 0285.5-2004
YY 0285.5-1999English439 Add to Cart 3 days [Need to translate] Sterile, single-use intravascular catheters. Part 5: Over-needle peripheral catheters Obsolete YY 0285.5-1999


BASIC DATA
Standard ID YY 0285.5-2018 (YY0285.5-2018)
Description (Translated English) Intravascular catheters--Sterile and single-use catheters--Part 5: Over-needle peripheral catheters
Sector / Industry Medical Device & Pharmaceutical Industry Standard
Classification of Chinese Standard C31
Classification of International Standard 11.040.20
Word Count Estimation 14,115
Date of Issue 2018-02-24
Date of Implementation 2019-03-01
Drafting Organization Shandong Medical Device Product Quality Inspection Center, Shandong Xinhua Ande Medical Products Co., Ltd.
Administrative Organization National Medical Infusion Instrument Standardization Technical Committee
Proposing organization State Food and Drug Administration
Issuing agency(ies) State Food and Drug Administration


YY 0285.5-2018 YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 C 31 Replacing YY 0285.5-2004 Intravascular catheters - Sterile and single-use catheters - Part 5. Over-needle peripheral catheters (ISO 10555-5.2013, MOD) ISSUED ON. FEBRUARY 24, 2018 IMPLEMENTED ON. MARCH 01, 2019 Issued by. China Food and Drug Administration Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Requirements ... 7  Appendix A (Normative) Determination of connection strength between needle hub and needle tube ... 10  Appendix B (Informative) Opaque catheter seat color ... 11  Appendix C (Informative) Needle tip geometry ... 12  Appendix D (Normative) Determination of liquid leakage from vent fittings ... 13  References ... 15  Foreword YY 0285 “Intravascular catheters - Sterile and single-use catheters” is divided into the following parts. - Part 1. General requirements; - Part 3. Central venous catheter; - Part 4. Balloon dilatation catheter; - Part 5. Over-needle peripheral catheters. This part is the part 5 of YY 0285. The following parts have been revoked and are already included in Part 1. - Part 2. Angiographic catheters. This part was drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces YY 0285.5-2004 “Intravascular catheters - Sterile and single- use catheters - Part 5. Over-needle peripheral catheters”. As compared with YY 0285.5-2004, the main changes are as follows. - MODIFY the normative reference documents; - DELETE Appendix A. This part uses the redrafting method to modify and use of ISO 10555-5.2013 “Intravascular catheters - Sterile and single-use catheters - Part 5. Over-needle peripheral catheters”. The technical differences and reasons for this part and ISO 10555-5.2013 are as follows. - Regarding the normative reference documents, this standard has made adjustments with technical differences, to adapt to the technical conditions of China. The adjustments are mainly reflected in clause 2 “Normative References”. The specific adjustments are as follows. • USE the GB/T 1962.1 which equivalently adopts international standards to substitute ISO 594-1; • USE the GB/T 18457 which equivalently adopts international standards to substitute ISO 9626; • USE the GB/T 0285.1 which adopts international standards through Intravascular catheters - Sterile and single-use catheters - Part 5. Over-needle peripheral catheters 1 Scope This part of YY 0285 specifies the requirements for over-needle peripheral catheters for insertion into the peripheral vasculature that are supplied sterile and in single-use. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 1962.1 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1. General requirement (GB/T 1962.1-2015, ISO 594-1.1986, IDT) GB/T 18457 Stainless steel needle tubing for the manufacture of medical devices (GB/T 18457-2015, ISO 9626.1991, MOD) YY 0285.1 Intravascular catheters - Sterile and single-use catheters - Part 1. General requirements (YY 0285.1-2017, ISO 10555-1.2013, MOD) 3 Terms and definitions The terms and definitions as defined in YY 0285.1 and the following terms and definitions apply to this document. 3.1 Over-needle peripheral intravascular catheter A catheter for introducing in or withdrawing out a fluid or instrument from a peripheral vascular system. 3.2 Needle Appendix A (Normative) Determination of connection strength between needle hub and needle tube A.1 Principle Apply tension and compression to the needle tube and the needle hub, then check for loose connections between the needle tube and the needle hub. A.2 Instrument The tensile tester can apply a force of 20 N with an accuracy of ±1%. A.3 Test procedure A.3.1 Condition the needle for 2 h under conditions of relative humidity of 40% ~ 60% and temperature of 22 °C ± 2 °C, immediately perform the test. A.3.2 Clamp the needle tube and the needle hub on the fixture of the tensile tester, then apply the tension and pressure one time at the speed of 100 mm/min in accordance with the following force values. - The test needle with a nominal outer diameter less than 0.6 mm. 10 N; - The test needle with the nominal outer diameter greater than or equal to 0.6 mm. 20 N. A.3.3 Check the connection between the needle tube and the needle hub, record whether the needle is loose. A.4 Test report The test report shall include the following information. a) Identification of the needle; b) The outer diameter of the needle, expressed in mm; c) The applied force (i.e. 10 N or 20 N); d) Whether the needle in the needle hub loosens. Appendix D (Normative) Determination of liquid leakage from vent fittings D.1 Principle The catheter is connected to a simulated blood source under hydrostatic pressure. Allow liquid to flow into the needle and measure the time it takes for the liquid to leak through the vent fitting. D.2 Test solution D.2.1 Dissolve 9 g of analytically pure sodium chloride in distilled or deionized water to prepare 1 L sodium chloride solution [0.9% (mass concentration)]. D.2.2 Mix 550 mL of sodium chloride solution (D.2.1) and 450 mL of USP grade or higher glycerin to prepare test solution. Note. To improve the observability, a coloring agent such as a red or blue food coloring agent may be added. D.3 Instrument D.3.1 Constant liquid level container, capable of providing 400 mm ± 20 mm static pressure head, equipped with a liquid supply pipeline with an inner diameter of not less than 3 mm, the liquid supply pipeline is equipped with a clip or valve, the end has a puncture membrane such as latex cover). An example of this device is shown in Figure D.1. D.3.2 Stopwatch, or similar device. D.4 Procedure D.4.1 Fill the test solution (D.2) at 23 °C ± 2 °C into a constant liquid level container (D.3.1). D.4.2 Discharge all air in the supply line and close the clamp or valve. D.4.3 Insert the needle tip into the membrane to ensure that the needle is maintained at ±5° from the horizontal plane. D.4.4 Open the clamp or valve to allow liquid to flow into the needle tube and measure the time it takes for the first drop to drop at the vent fitting. D.5 Test report ......


YY/T 0285:5-2018: Intravascular Catheters Disposable Sterile Catheters Part 5: Trocar Peripheral Catheters ICS 11:040:20 C31 Pharmaceutical Industry Standard of the People's Republic of China YY 0285:5-2018 Replace YY 0285:5-2004 Intravascular Catheters Disposable Sterile Catheters Part 5: Trocar peripheral catheters (ISO 10555-5:2013, MOD) According to the State Drug Administration medical device industry Standard Announcement (No: 76 of 2022), this standard is from From September 7, 2022, it will be converted into a recommended standard, no Enforce it again: Released on:2018-02-24 Implemented on:2019-03-01 Issued by China Food and Drug Administration foreword YY 0285 "Intravascular Catheter Disposable Sterile Catheter" is divided into the following parts: --- Part 1: General requirements; --- Part 3: Central venous catheters; --- Part 4: Balloon dilatation catheters; --- Part 5: Trocar peripheral catheter: This part is the fifth part of YY 0285: The following parts have been withdrawn and have been included in Part 1: --- Part 2: Contrast catheter: This section is drafted in accordance with the rules given in GB/T 1:1-2009: This Part replaces YY 0285:5-2004 "Single-use Sterile Intravascular Catheters Part 5: Trocar Peripheral Catheters", and Compared with YY 0285:5-2004, the main revisions are as follows: ---Modified the normative reference documents; --- Deleted Appendix A: This part uses the redrafted law to revise and adopt ISO 10555-5:2013 "Intravascular catheters for single-use sterile catheters Part 5 Subsection: Trocar Peripheral Catheters: The technical differences between this part and ISO 10555-5:2013 and the reasons are as follows: --- Regarding the normative reference documents, this standard has made adjustments with technical differences to adapt to the technical conditions of our country and the adjustment situation The situation is reflected in Chapter 2 "Normative References", and the specific adjustments are as follows: ● Replaced ISO 594-1 with GB/T 1962:1, which is equivalent to the international standard; ● Replaced ISO 9626 with GB/T 18457, which is equivalent to the international standard; ● Replacing ISO 10555-1 with YY 0285:1 which adopts the international standard: Please note that some contents of this document may refer to patents: The issuing agency of this document assumes no responsibility for identifying these patents: This part is proposed by China Food and Drug Administration: This part is under the jurisdiction of the National Standardization Technical Committee of Medical Infusion Sets: This part is drafted by: Shandong Provincial Medical Device Product Quality Inspection Center, Shandong Xinhua Ande Medical Supplies Co:, Ltd: The main drafters of this section: Li Yuanyu, Liu Bin, Tian Xiaolei, Gao Ranran: The previous version releases replaced by this part are as follows: ---YY 0285:5-2004, YY 0285:5-1999: YY 0285:5-2018 Intravascular Catheters Disposable Sterile Catheters Part 5: Trocar peripheral catheters 1 Scope This part of YY 0285 specifies the blood trocars supplied in a sterile state and used for single use for insertion into the peripheral vascular system In-line catheter requirements: 2 Normative references The following documents are indispensable for the application of this document: For dated references, only the dated version applies to this document pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 1962:1 Syringes, injection needles and other medical devices 6% (Luer) conical fittings Part 1: General requirements (GB/T 1962:1-2015, ISO 594-1:1986, IDT) GB/T 18457 Manufacture of stainless steel needle tubes for medical devices (GB/T 18457-2015, ISO 9626:1991, MOD) YY 0285:1 Intravascular Catheters Sterile Disposable Catheters Part 1: General Requirements (YY 0285:1-2017, ISO 10555-1:2013, MOD) 3 Terms and Definitions The following terms and definitions defined in YY 0285:1 apply to this document: 3:1 A catheter used to introduce or remove fluids or devices from the peripheral vasculature: 3:2 needle needle An assembly including at least one needle tube and a hub that fixes it and communicates with it: see picture 1: 3:3 needle tube A rigid tube that is cut at one end to facilitate entry into body tissue: 3:4 needle hub The connector for fixing the needle tube, the inner hole of which communicates with the needle tube: 3:5 Exhaust joint ventfitting A fitting used to vent gas while restricting or preferably preventing the outflow of blood: Divided into two kinds of fixed or movable: 3:6 catheter assembly catheterunit An assembly consisting of catheter tubing, a catheter adapter, and any integral connectors: see picture 1: YY 0285:5-2018 ......

Similar standards: YY/T 0285.6-2020  YY 0285.1-2017  
Similar PDFs (Auto-delivered in 9 seconds): YY 0285.5-2018  YY 0285.4-2017  YY/T 0285.6-2020  YY 0285.3-2017