HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

YY/T 0031-2008 PDF English

US$70.00 · In stock · Download in 9 seconds
YY/T 0031-2008: Silicone tubes and elastomeric parts for infusion and transfusion
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure

YY/T 0031: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YY/T 0031-2008English70 Add to Cart 0-9 seconds. Auto-delivery Silicone tubes and elastomeric parts for infusion and transfusion  
YY/T 0031-1990EnglishRFQ ASK 3 days (Silicone rubber infusion (blood) Tube) Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YY/T 0031-2008
      

Similar standards

YY/T 0243   HAD 002/01   HG/T 2584   

YY/T 0031-2008: Silicone tubes and elastomeric parts for infusion and transfusion

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0031-2008
NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 C 31 Replacing YY/T 0031-1990 Silicone tubes and elastomeric parts for infusion and transfusion ISSUED ON: OCTOBER 17, 2008 IMPLEMENTED ON: JANUARY 01, 2010 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Product classification ... 5 4 Requirements ... 5 5 Packaging, marks ... 8 Annex A (normative) Steam resistance test ... 9 Annex B (normative) Physical test ... 11 Annex C (normative) Soluble substance test ... 12 Silicone tubes and elastomeric parts for infusion and transfusion

1 Scope

This Standard specifies the general requirements and test methods for silicone tubes for infusion and transfusion (hereinafter referred to as “the tubes”) and elastomeric parts. The products to which this Standard is applicable include (but are not limited to): -- Reusable in vitro transfer lines for intravenous infusion; -- Disposable silicone rubber elastic parts in blood treatment products, such as pump tubing, valves or seals for flow control devices, injection parts; -- Silicone rubber elastic parts for disposable infusion apparatus, such as silicone rubber reservoirs for injection parts and infusion pumps; -- Pump tubes, valves, and injection parts in disposable pressure infusion lines. This Standard does not include silicone rubber catheters and artificial heart- lung machine pump tubes inserted or implanted in the human body.

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. GB/T 528, Rubber, vulcanized or thermoplastic - Determination of tensile stress-strain properties (GB/T 528-1998, eqv ISO 37:1994) GB/T 529, Rubber, vulcanized - Determination of tear strength (trouser, angle and crescent test pieces) (GB/T 529-1999, eqv ISO 34-1:1994) GB/T 3512, Rubber, vulcanized or thermoplastic - Accelerated ageing and

Annex A

(normative) Steam resistance test A.1 Principle For silicone rubber products that are expected to undergo steam sterilization, use a specimen that is obtained with same production process and is in accordance with GB/T 528, after subjecting to the saturated steam at specified temperature to the specified time, to determine the reduction rate of physical properties before and after this process. A.2 Test instruments Pressure steam sterilizer (temperature control accuracy is within ±2°C). A.3 Steps A.3.1 Conduct the breaking strength test and the break elongation test to the specimen according to the provisions of GB/T 528. A.3.2 Use 100°C water to inject into the pressure steam sterilizer. Then hang the unstretched specimen in the sterilizer to make the specimen spacing not less than 5cm, the distance between the specimen and the wall not less than 10cm. Quickly heat to 121°C and remain the constant temperature for 2h. After the specified time, when it is immediately cooled to 100°C, take out the specimen. Hang at room temperature for 4h±0.5h. Then conduct the breaking strength test and the break elongation test to the specimen according to the provisions of GB/T 528. A.4 Result expression Calculate the percent reduction of the performance according to the following formula: Where, η - The percent reduction of the performance; A - The determined value of specimen performance after hot steam treatment;

Annex C

(normative) Soluble substance test C.1 Preparation of inspection solution C.1.1 Pipeline Take 8g of pipeline. Cut it into 10mm pieces. Use distilled water to wash at least 3 times. Place the specimen into a ground bottle. Add 100mL of distilled water to make the specimen immersed in the distilled water. Then put it into the pressure steam sterilizer at 121°C±2°C for 1h. Then take it out. Cool to room temperature. Use the distilled water of same batch after the same treatment as the blank control solution. C.1.2 Elastomeric parts C.1.2.1 When the expected use time of the elastomeric parts exceeds 24h, take 8g of pipeline. Cut into 10mm pieces. Use distilled water to wash 3 times. Place the specimen into a ground bottle. Add 100mL of distilled water to make the specimen immersed in the distilled water. Then soak it at 70°C±2°C for 24h and take it out. Cool to room temperature. Use the distilled water of same batch after the same treatment as the blank control solution. C.1.2.2 When the expected use time of the elastomeric parts does not exceed 24h, take 8g of elastomeric parts. Cut into 10mm pieces. Use distilled water to wash 3 times. Place the specimen in a ground bottle. Add 100mL of distilled water to make the specimen immersed in the distilled water. Then soak it at 37°C±2°C for 24h and take it out. Cool to room temperature. Use the distilled water of same batch after the same treatment as the blank control solution. C.2 Color Take inspection solution in a colorimetric tube. Visually observe if the solution is colorless and transparent. C.3 pH value Take inspection solution and blank control solution. Use a PH meter to respectively test pH values to confirm whether the difference between those two complies with the provisions of Table 3. C.4 Evaporation residues ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YY/T 0031-2008 be delivered?

Answer: The full copy PDF of English version of YY/T 0031-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 0031-2008_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0031-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YY/T 0031-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version YY/T 0031-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YY/T 0031-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of YY/T 0031-2008?

A step-by-step guide to download PDF of YY/T 0031-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 0031-2008".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9