YS/T 928.4-2013 PDF English
US$170.00 · In stock · Download in 9 secondsYS/T 928.4-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
| YS/T 928.4-2013 | English | 170 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: YS/T 928.4-2013
YS/T 928.4-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST928.4-2013
YS
NONFERROUS INDUSTRY STANDARD
ICS 77.120.60
H 13
Methods for Chemical Analysis of Nickel Cobalt Manganese
Composite Hydrogenoxide - Part 4.Determination of Iron,
Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,
Sodium Contents - Inductively Coupled Plasma Atomic
Emission Spectrometric
Issued on. OCTOBER 17, 2013
Implemented on. MARCH 1, 2014
Issued by. Ministry of Industry and Information Technology of the People’s
Republic of China
Table of Contents
Foreword... 3
1 Scope... 4
2 Method Summary... 4
3 Reagents... 5
4 Instrument... 6
5 Analytical Procedures... 7
6 Calculation and Expression of Analysis Results... 8
7 Precision... 8
8 Test Report... 10
Foreword
YS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite
Hydrogenoxide includes the following six parts.
---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry;
---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric;
---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled
Plasma Atomic Emission Spectrometric;
---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,
Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric;
---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass
Spectrometry;
---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography.
This is Part 4 of YS/T 928.
This Part was drafted in accordance with the rules provided in GB/T 1.1-2009.
This Standard shall be under the jurisdiction of National Technical Committee 243 on
Nonferrous Metals of Standardization Administration of China (SAC/TC 243).
The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan
BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining &
Metallurgy.
The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling
Technology Co., Ltd.
The participating drafting organizations of this Part. Zhejiang Huayou Cobalt Co., Ltd.; Tianjin
Maolian Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co., Ltd.
The main drafters of this Part. Guo Peiqing, Li Changdong, Qin Fanglin, Yu Haijun, Qiu Ping,
Wu Yahui, Xie Bohua, Zhang Ping, Pan Haiyun, Ren Xingting.
Methods for Chemical Analysis of Nickel Cobalt Manganese
Composite Hydrogenoxide - Part 4.Determination of Iron,
Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,
Sodium Contents - Inductively Coupled Plasma Atomic
Emission Spectrometric
1 Scope
This Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium,
copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite
hydrogenoxide.
This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon,
aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table
1 for the determination scope.
Table 1 -- Determination Scope
2 Method Summary
Use hydrochloric acid to dissolve the test portion and adopt an inductively coupled plasma
atomic emission spectrometer to directly conduct the determination. In accordance with the
working curve method, calculate the concentration of each element. Express the determination
results in mass fraction.
Element Determination Scope (w)/%
3 Reagents
All reagents used in this Part are of top-grade purity, and only pure water with an electrical
resistivity of not less than 18.2 M cm shall be used in the analysis.
3.1 Hydrochloric acid (ρ = 1.19 g/mL).
3.2 Nitric acid (ρ = 1.42 g/mL).
3.3 Hydrochloric acid (1 + 1).
3.4 Nitric acid (1 + 1).
3.8 Copper standard stock solution. weigh-take 0.2000 g of pure copper (wCu 99.99%) in a
300 mL beaker, slowly add 30 mL of nitric acid (3.4), use a watch glass to cover it; at a low
temperature, dissolve it and drive out nitrogen oxides, then, remove and cool it. Use water to
wash the watch glass and beaker wall. Transfer to a 1,000 mL volumetric flask, use water to
dilute to the scale and mix it well. 1 mL of this solution contains 200 g of copper.
3.13 Aluminum, magnesium, calcium, copper, iron and zinc standard solutions. accurately
transfer-take 10.00 mL of the standard stock solutions (3.5, 3.6, 3.7, 3.8, 3.9 and 3.10) in a 200
mL volumetric flask. Use water to dilute to the scale and mix it well. 1 mL of this solution
contains 10 g of aluminum, magnesium, calcium, copper, iron and zinc.
3.14 Sodium standard solution. accurately transfer-take 10.00 mL of the standard stock solution
(3.11) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and
immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 g of sodium.
3.15 Silicon standard solution. accurately transfer-take 10.00 mL of the standard stock solution
(3.12) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and
immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 g of silicon.
4 Instrument
In terms of the inductively coupled plasma atomic emission spectrometer, the spectral lines of
the various element are shown in Table 2; the working parameters of the instrument for sodium
determination are shown in Table 3; the working parameters of the instrument for the
determination of other elements are shown in Table 4.
5 Analytical Procedures
5.1 Test Portion
Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g.
5.2 Blank Test
Along with the specimen, conduct the blank test.
5.3 Treatment of Test Portion
Place the test portion (5.1) in a 100 mL polytetrafluoroethylene beaker, add 20 mL of
hydrochloric acid (3.3), use a watch glass to cover it, dissolve it with slight heat. After the test
portion is completely dissolved, remove it, cool it, then, use water to wash the watch glass and
beaker wall. Transfer it to a 200 mL volumetric flask, use water to dilute to the scale and mix it
well. On an inductively coupled plasma atomic emission spectrometer, conduct the
determination.
5.4 Drawing of Working Curve
7 Precision
7.1 Repeatability
Under repeatability conditions, obtain the determined values of two independent test results.
Within the average value range provided in Table 5, the absolute difference between the two
test results does not exceed the repeatability limit (r), and the circumstances of exceeding the
repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the
linear interpolation method and the extrapolation method in accordance with the data in Table
5.
8 Test Report
The test report shall include the following content.
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of YS/T 928.4-2013 be delivered?Answer: The full copy PDF of English version of YS/T 928.4-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of YS/T 928.4-2013_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 928.4-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YS/T 928.4-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of YS/T 928.4-2013?A step-by-step guide to download PDF of YS/T 928.4-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "YS/T 928.4-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|