YS/T 928.3-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 3: Determination of nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectromertric
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YS/T 928.3-2013English110 Add to Cart 0-9 seconds. Auto-delivery Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 3: Determination of nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectromertric Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YS/T 928.3-2013
      

Similar standards

GB/T 3884.2   GB/T 3884.1   YS/T 928.2   

YS/T 928.3-2013: Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 3: Determination of nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectromertric



---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST928.3-2013
YS NONFERROUS INDUSTRY STANDARD ICS 77.120.60 H 13 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide - Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled Plasma Atomic Emission Spectrometric Issued on. OCTOBER 17, 2013 Implemented on. MARCH 1, 2014 Issued by. Ministry of Industry and Information Technology of the People’s Republic of China

Table of Contents

Foreword... 3 1 Scope... 4 2 Method Summary... 4 3 Reagents... 4 4 Instrument... 6 5 Analytical Procedures... 6 6 Calculation and Expression of Analysis Results... 7 7 Precision... 8 8 Test Report... 8

Foreword

YS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide includes the following six parts. ---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry; ---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric; ---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled Plasma Atomic Emission Spectrometric; ---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum, Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric; ---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass Spectrometry; ---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography. This is Part 3 of YS/T 928. This Part was drafted in accordance with the rules provided in GB/T 1.1-2009. This Standard shall be under the jurisdiction of National Technical Committee 243 on Nonferrous Metals of Standardization Administration of China (SAC/TC 243). The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining & Metallurgy. The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling Technology Co., Ltd. The participating drafting organizations of this Part. Hunan Nonferrous Metals Research Institute; Yingde Jiana Metal Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co., Ltd.; Tianjin Maolian Technology Co., Ltd. The main drafters of this Part. Guo Peiqing, Li Changdong, Guo Jing, Tang Hai, Qiu Ping, Xie Minghong, Tan Pingsheng, Pang Wenlin, Wu Chichun, Luo Yueying, Ren Xingting, Pan Haiyun. Methods for Chemical Analysis of Nickel Cobalt Manganese Composite Hydrogenoxide - Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled Plasma Atomic Emission Spectrometric

1 Scope

This Part of YS/T 928 specifies the method for the determination of nickel, cobalt and manganese content in nickel cobalt manganese composite hydrogenoxide. This Part is applicable to the determination of nickel, cobalt and manganese content in nickel cobalt manganese composite hydrogenoxide. See Table 1 for the determination scope. Table 1 -- Determination Scope

2 Method Summary

Use hydrochloric acid to dissolve the test portion, use yttrium as the internal standard, and adopt an inductively coupled plasma atomic emission spectrometer to determine the elements to be analyzed.

3 Reagents

Unless it is otherwise stated, only reagents confirmed to be analytically pure and pure water with an electrical resistivity of not less than 18.2 M  cm shall be used in the analysis. 3.1 Hydrochloric acid (ρ = 1.19 g/mL). 3.2 Nitric acid (ρ = 1.42 g/mL). 3.3 Hydrochloric acid (1 + 1). 3.4 Nitric acid (1 + 1). Element Determination Scope/% 3.7 Nickel standard stock solution. weigh-take 2.0000 g of pure nickel (wNi  99.99%) in a 300 mL beaker, add 40 mL of hydrochloric acid (3.1) and 5 mL of nitric acid (3.2); heat to dissolve it. Boil to remove nitrogen oxides, remove and cool it, then, use water to wash the watch glass and beaker wall. Transfer to a 500 mL volumetric flask, use water to dilute to the scale and mix it well. 1 mL of this solution contains 4 mg of nickel. 3.10 Nickel cobalt manganese standard solution 955.accurately transfer-take 15.00 mL, 20.00 mL and 30.00 mL of nickel standard stock solution (3.7), and 2.00 mL, 3.00 mL and 5.00 mL of cobalt standard stock solution (3.8) and manganese standard stock solution (3.9) in a group of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A (3.5), use water to dilute to the scale and mix it well. 3.11 Nickel cobalt manganese standard solution 811.accurately transfer-take 15.00 mL, 20.00 mL and 25.00 mL of nickel standard stock solution (3.7), and 5.00 mL, 7.00 mL and 10.00 mL of cobalt standard stock solution (3.8) and manganese standard stock solution (3.9) in a group of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A (3.5), use water to dilute to the scale and mix it well. 3.12 Nickel cobalt manganese standard solution 523.accurately transfer-take 10.00 mL, 15.00 mL and 18.00 mL of nickel standard stock solution (3.7), and 10.00 mL, 12.00 mL and 15.00 mL of cobalt standard stock solution (3.8), and 10.00 mL, 15.00 mL and 20.00 mL of manganese standard stock solution (3.9) in a group of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A (3.5), use water to dilute to the scale and mix it well. 3.13 Nickel cobalt manganese standard solution 424.accurately transfer-take 10.00 mL, 12.00 mL and 15.00 mL of nickel standard stock solution (3.7) and cobalt standard stock solution (3.8), and 15.00 mL, 25.00 mL and 30.00 mL of manganese standard stock solution (3.9) in a group of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A (3.5), use water to dilute to the scale and mix it well.

4 Instrument

The working parameters of the inductively coupled plasma atomic emission spectrometer are shown in Table 2.

5 Analytical Procedures

5.1 Test Portion Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g. 5.2 Blank Test Along with the specimen, conduct the blank test. 5.3 Treatment of Test Portion Place the test portion (5.1) in a 300 mL beaker, add 20 mL of hydrochloric acid (3.3), use a watch glass to cover it; completely dissolve it at low temperature. Remove and cool it, then, use water to wash the watch glass and beaker wall. 5.4 Drawing of Working Curve On the ICP optical spectrometer, in accordance with the condition parameters provided in Table 2 and Table 3, use yttrium internal standard solution B (3.6) and nickel cobalt manganese standard solutions (3.10, 3.11, 3.12, 3.13, 3.14 and 3.15) to measure the intensity values of the nickel, cobalt and manganese standard solutions.

6 Calculation and Expression of Analysis Results

In accordance with Formula (1), calculate the mass fraction wx of the element being determined and express it as a percentage.

7 Precision

7.1 Repeatability Under repeatability conditions, obtain the determined values of two independent test results. Within the average value range provided in Table 5, the absolute difference between the two test results does not exceed the repeatability limit (r), and the circumstances of exceeding the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the linear interpolation method and the extrapolation method in accordance with the data in Table 4.

8 Test Report

The test report shall include the following content. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YS/T 928.3-2013 be delivered?

Answer: The full copy PDF of English version of YS/T 928.3-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YS/T 928.3-2013_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 928.3-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YS/T 928.3-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YS/T 928.3-2013?

A step-by-step guide to download PDF of YS/T 928.3-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YS/T 928.3-2013".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9