Powered by Google www.ChineseStandard.net Database: 189759 (21 Apr 2024)

YS/T 273.5-2006 (YST273.5-2006)

YS/T 273.5-2006_English: PDF (YST 273.5-2006, YST273.5-2006)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
YS/T 273.5-2006English100 Add to Cart 0--9 seconds. Auto-delivery Chemical analysis methods and physical properties of cryolite. Part 5: Determination of sodium by flame atomic absorption spectrometric method YS/T 273.5-2006

BASIC DATA
Standard ID YS/T 273.5-2006 (YS/T273.5-2006)
Description (Translated English) Chemical analysis methods and physical properties of cryolite. Part 5: Determination of sodium by flame atomic absorption spectrometric method
Sector / Industry Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard H21
Classification of International Standard 71.100.10
Word Count Estimation 6,670
Date of Issue 2006-05-25
Date of Implementation 2006-12-01
Older Standard (superseded by this standard) YS/T 273.5-1994
Drafting Organization Fushun Aluminum Co., Ltd.
Administrative Organization National Standardization Technical Committee of non-ferrous metals
Regulation (derived from) NDRC Notice No. 36 of 2006
Proposing organization National Nonferrous Metals Standardization Technical Committee
Issuing agency(ies) National Development and Reform Commission
Summary This standard specifies the cryolite Determination of sodium content. This standard applies to the determination of sodium cryolite. Measuring range: 20% to 35%.

Standards related to: YS/T 273.5-2006

YS/T 273.5-2006
YS
NONFERROUS METAL INDUSTRY STANDARD
OF THE PEOPLE'S REPUBLIC OF CHINA
ICS 71.100.10
H 21
Replacing YS/T 273.5-1994
Chemical analysis methods and physical properties of
cryolite - Part 5: Determination of sodium by flame atomic
absorption spectrometric method
ISSUED ON: MAY 25, 2006
IMPLEMENTED ON: DECEMBER 1, 2006
Issued by: National Development and Reform Commission of PRC
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Method summary ... 5
3 Reagents ... 5
4 Apparatus ... 5
5 Sample ... 6
6 Analysis procedure ... 6
7 Calculation of analysis results ... 7
8 Precision ... 8
9 Quality assurance and control ... 8
Foreword
YS/T 273 "Chemical analysis methods and physical properties of cryolite" is divided
into 13 parts:
-- Part 1: Determination of moisture content - Gravimetric method;
-- Part 2: Determination of ignition loss;
-- Part 3: Determination of fluoride content;
-- Part 4: Determination of aluminum content - EDTA titration method;
-- Part 5: Determination of sodium by flame atomic absorption spectrometric
method;
-- Part 6: Determination of silica content by the molybdenum blue photometric;
-- Part 7: Determination of iron content by orthophenantholine photometric method;
-- Part 8: Determination of sulfate content - Barium sulfate gravimetric method;
-- Part 9: Determination of phosphorus pentoxide content - Molybdenum blue
photometric method;
-- Part 10: Determination of alumina content by gravimetric method;
-- Part 11: Determination of sulphur content by X-ray fluorescence spectrometric
method;
-- Part 12: The atomic absorption spectrophotometric method for the determination
of calcium oxide content;
-- Part 13: Preparation and storage of test samples.
This Part is Part 5.
This part is a revision of YS/T 273.5-1994. In addition to editorial modification, two
chapters on Precision AND Quality Assurance and Control have been added. Other
changes include:
-- The measuring wavelength of the instrument is changed from the most sensitive
589.0 nm to the hypo-sensitive 589.6 nm;
-- The length of the working curve is shortened, and the concentration of the highest
concentration standard solution in the working curve is reduced from 10.0
μg/mL to 5.00 μg/mL;
Chemical analysis methods and physical properties of
cryolite - Part 5: Determination of sodium by flame atomic
absorption spectrometric method
1 Scope
This Part specifies the method for the determination of sodium content in cryolite.
This Part applies to the determination of sodium content in cryolite. Determination
range: 20%~35%.
2 Method summary
After the test portion is dissolved with sulfuric acid, it is heated to remove fluorine, and
the precipitate is dissolved with hydrochloric acid and water; the sodium content of the
test solution is determined at the wavelength of 589.0 nm or 589.6 nm of an atomic
absorption spectrometer by the use of an air-acetylene fuel-lean flame.
3 Reagents
3.1 Sulfuric acid (ρ 1.84 g/mL).
3.2 Hydrochloric acid (ρ 1.19 g/mL).
3.3 Sodium standard solution: Weigh 3.089 g of anhydrous sodium sulfate that has been
dried at 120 °C and cooled in a desiccator, place it in a 250 mL beaker, and add 100 mL
of water to dissolve; then, add 10 mL of hydrochloric acid (3.2), transfer the solution to
a 1000 mL volumetric flask, dilute to volume with water, mix well, and transfer it to a
polyethylene bottle. 1 mL of this solution contains 1.000 mg of sodium.
4 Apparatus
4.1 Platinum dish: The diameter is 80 mm, and the height is 35 mm.
4.2 Atomic absorption spectrometer: It is equipped with a sodium hollow cathode lamp.
Any instrument that can meet the following indicators under the best working
conditions can be used.
-- Characteristic concentration: In a solution consistent with the matrix of the
measured sample, the characteristic concentration of sodium shall not be greater
than 0.07 ug/mL.
-- Precision: Use the standard solution with the highest concentration to measure
the absorbance 10 times, and the standard deviation shall not exceed 1.0% of
the average absorbance; use the standard solution with the lowest concentration
(not the "zero" concentration standard solution) to measure the absorbance 10
times, and the standard deviation shall not exceed 0.5% of the average
absorbance of the highest concentration standard solution.
-- Working curve linearity: Divide the working curve into 5 equal segments
according to concentration, and the ratio of the absorbance difference in the
highest segment to the absorbance difference in the lowest segment is not less
than 0.85.
5 Sample
The sample shall comply with the requirements of 3.3 in YS/T 273.13.
6 Analysis procedure
6.1 Test portion
Weigh 0.5 g of test sample (5), accurate to 0.0001 g.
6.2 Number of determinations
Two determinations shall be carried out independently and the average value shall be
taken.
6.3 Blank test
Do a blank test along with the sample test.
6.4 Determination
6.4.1 Place the test portion (6.1) in the platinum dish (4.1), add 5 mL of sulfuric acid
(3.1), and slowly dissolve it in a sand bath (15 min~20 min) to remove fluorine; then,
heat it to evaporate until the thick smoke emits; remove the test portion and cool it to
room temperature; add 3 mL of hydrochloric acid (3.2) and 30 mL of water, and heat in
a low-temperature sand bath until all salts are dissolved. After cooling, transfer the
solution to a 500 mL volumetric flask, dilute to volume with water, and mix well.
6.4.2 According to Table 1, take the test solution (6.4.1), place it in a 500 mL volumetric
...