HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

YS/T 252.5-2007 PDF English

US$95.00 · In stock · Download in 9 seconds
YS/T 252.5-2007: Methods for chemical analysis of nickel matte. Determination of sulfur content. Combustion-neutralization titrimetric method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YS/T 252.5-2007English95 Add to Cart 0-9 seconds. Auto-delivery Methods for chemical analysis of nickel matte. Determination of sulfur content. Combustion-neutralization titrimetric method  

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YS/T 252.5-2007
      

Similar standards

GB/T 3884.2   GB/T 3884.1   YS/T 252.7   

YS/T 252.5-2007: Methods for chemical analysis of nickel matte. Determination of sulfur content. Combustion-neutralization titrimetric method


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST252.5-2007
YS NONFERROUS INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.40 H 13 Replacing YS/T 252.5-1994 Methods for chemical analysis of nickel matte - Determination of sulfur content - Combustion-neutralization titrimetric method ISSUED ON: APRIL 13, 2007 IMPLEMENTED ON: OCTOBER 01, 2007 Issued by: National Development and Reform Commission of PRC

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Method summary ... 5 3 Reagents ... 5 4 Instruments ... 6 5 Analytical procedures ... 7 6 Calculation and expression of analysis results ... 8 7 Precision ... 8 8 Quality assurance and control ... 9

Foreword

YS/T 252 "Methods for chemical analysis of nickel matte" is divided into five parts: YS/T 252.1 Methods for chemical analysis of nickel matte - Determination of nickel content - Dimethylglyoxime gravimetric method YS/T 252.2 Methods for chemical analysis of nickel matte - Determination of iron content - Sulfosalicylic acid photometric method YS/T 252.3 Methods for chemical analysis of nickel matte - Determination of cobalt content - Flame atomic absorption spectrometric method YS/T 252.4 Methods for chemical analysis of nickel matte - Determination of cobalt content - Sodium thiosulphate titrimetric method YS/T 252.5 Methods for chemical analysis of nickel matte - Determination of sulfur content - Combustion-neutralization titrimetric method This Part is Part 5. This Part replaces YS/T 252.5-1994 "Determination of sulfur content by sodium thiosulphate titrimetric method ". Compared with YS/T 252.5-1994, this Part mainly has the following changes: - CHANGE the analysis method from barium sulfate gravimetric method to combustion-neutralization titration method; - ADD repeatability limits, supplementing quality assurance and control terms. This Part was proposed by AND shall be under the jurisdiction of the National Technical Committee for Standardization of Nonferrous Metals. Responsible drafting organization of this Part: Jinchuan Group Co., Ltd. Participated drafting organization of this Part: Beijing General Research Institute of Mining and Metallurgy, Daye Nonferrous Metals Co., Ltd. The main drafters of this Part: Liu Haidong, Yu Shengjie, Yang Xiuping, Lin Xiuying, Zhao Junfeng, Zhu Yuqiang. The main verifiers of this Part: Xu Xiaoyan, Ruan Guise, Guo Xiaohong, and Li Haiqiong. The National Nonferrous Metals Standardization Technical Committee is responsible for the interpretation of this Part. Methods for chemical analysis of nickel matte - Determination of sulfur content - Combustion-neutralization titrimetric method

1 Scope

This Part specifies the method for determination of sulfur content in high nickel matte. This Part is applicable to the determination of sulfur content in high nickel matte. Measuring range: 15% ~ 25%.

2 Method summary

The sample uses copper wire as flux and burns in air flow at 1250 °C ~ 1300 °C, to convert sulfur into sulfur dioxide. It is absorbed and oxidized into sulfuric acid by hydrogen peroxide. Methyl red-methylene blue solution is used as a mixed indicator. Use sodium hydroxide standard titration solution to make titration, until the solution changes from purple to bright green, which is taken as the end point.

3 Reagents

3.1 Copper wire (mass fraction of copper ≥ 99.95%, diameter 0.25 mm ~ 0.5 mm). 3.2 Acid absorption solution (potassium dichromate-sulfuric acid solution): Heat and dissolve 5 g of potassium dichromate with a small amount of water. After cooling, add 100 mL of sulfuric acid. 3.3 Desiccant: Anhydrous calcium chloride. 3.4 Alkali absorption solution: Sodium hydroxide (50 g/L). 3.5 Phenolphthalein indicator (10 g/L), ethanol solution. 3.6 Methyl red-methylene blue mixed indicator: Weigh 0.3 g of methyl red and 0.25 g of methylene blue. Dissolve in 500 mL of absolute ethanol. 3.7 Hydrogen peroxide absorption solution (prepared when used): Take 50 mL of hydrogen peroxide. Use water to dilute it to 1 L. Add 10 mL of mixed indicator (3.6). Use sodium hydroxide solution (3.8) to make adjustment, until bright green appears. 3.8 Sodium hydroxide standard titration solution [c(NaOH) ≈ 0.065 mol/L]: 3.8.1 Preparation: Prepare sodium hydroxide into a saturated solution. Place it in a plastic bottle until the solution is clear. Pipette 32 mL of supernatant. Use carbon dioxide-free water to dilute it to 10 L. Mix well. 3.8.2 Calibration: Weigh four sets of 0.300 g (accurate to 0.0001 g) of potassium hydrogen phthalate (standard reagent), that has been dried at 100 °C ~ 105 °C for 2 hours. Place it in a 300 mL Erlenmeyer flask. Use 60 mL of hot water, which does not contain carbon dioxide, to dissolve it. After cooling, add 2 drops of phenolphthalein indicator (3.5). Use sodium hydroxide standard titration solution to make titration, until it shows light red, which is taken as end point. Do a blank test along with the calibration. Calculate the titration coefficient of sodium hydroxide standard titration solution for sulfur, according to formula (1): Where: FS - Titration coefficient, the mass of sulfur equivalent to 1.00 mL of sodium hydroxide standard titration solution, in milligrams per milliliter (mg/mL); m1 - The mass of potassium hydrogen phthalate, in grams (g); V1 - During calibration, the volume of sodium hydroxide standard titration solution consumed in titrating potassium hydrogen phthalate solution, in milliliters (mL); V0 - During calibration, the volume of sodium hydroxide standard titration solution consumed by titrating the blank test solution, in milliliters (mL); 204.2 - Molar mass of potassium hydrogen phthalate [M(C8H5KO4)], in grams per mole (g/mol); 16.03 - Molar mass of sulfur [M(1/2S)], in grams per mole (g/mol). Take the average of four results. The range of the four calibration results is not greater than 0.0060 mg/mL; otherwise, the measurement will be repeated.

4 Instruments

4.1 Tubular combustion furnace: The maximum temperature 1350 °C, common temperature 1300 °C, equipped with resistance furnace temperature controller (0 °C ~ 1600 °C). ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YS/T 252.5-2007 be delivered?

Answer: The full copy PDF of English version of YS/T 252.5-2007 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YS/T 252.5-2007_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 252.5-2007_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YS/T 252.5-2007 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YS/T 252.5-2007?

A step-by-step guide to download PDF of YS/T 252.5-2007_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YS/T 252.5-2007".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9