Chinese Standards Shop Partner of Google-Books Database: 169760 (Nov 9, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

YD/T 1595.1-2012

Chinese Standard: 'YD/T 1595.1-2012'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
YD/T 1595.1-2012English240 Add to Cart 0--15 minutes. Auto immediate delivery. Requirements and measurement methods of electromagnetic compatibility for 2GHz WCDMA digital cellular mobile telecommunications system - Part 1: user equipment and ancillary equipment Valid YD/T 1595.1-2012
YD/T 1595.1-2012Chinese20 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

 YD/T 1595.1-2012 -- Click to view a PDF In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email by our cloud-server.  
Detail Information of YD/T 1595.1-2012; YD/T1595.1-2012
Description (Translated English): Requirements and measurement methods of electromagnetic compatibility for 2GHz WCDMA digital cellular mobile telecommunications system - Part 1: user equipment and ancillary equipment
Sector / Industry: Telecommunication Industry Standard (Recommended)
Classification of Chinese Standard: M04
Classification of International Standard: 01.040.33
Word Count Estimation: 23,290
Older Standard (superseded by this standard): YD/T 1595.1-2007
Quoted Standard: GB 9254; GB 17625.1; GB 17625.2; GB/T 6113.101; GB/T 6113.104; GB/T 17626.2; GB/T 17626.3; GB/T 17626.4; GB/T 17626.5; GB/T 17626.6; GB/T 17626.8; GB/T 17626.11; GB/T 17626.29; GB/T 21437.2; YD/T 1312.1-2008; YD/T 1483; YD/T 1978
Drafting Organization: MIIT Telecommunications Research Institute
Administrative Organization: China Communications Standards Association
Regulation (derived from): Ministry of Industry and Information Technology Bulletin 2012 No. 70; industry standard filing Notice 2013 No. 3 (total 159)
Summary: This standard specifies the 2GHz WCDMA digital cellular mobile communication system user equipment and auxiliary equipment, electromagnetic compatibility (EMC) requirements, including limits, performance criteria and measurement methods. This standard app

YD/T 1595.1-2012
YD
COMMUNICATION INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 01.040.33
M 04
Replacing YD/T 1595.1-2007
Requirements and measurement methods of
electromagnetic compatibility for 2GHz WCDMA digital
cellular mobile telecommunication system –
Part 1. user equipment and ancillary equipment
2GHz WCDMA数字蜂窝移动通信系统的
电磁兼容性要求和测量方法 第 1部分. 用户设备及其辅助设备
ISSUED ON. DECEMBER 28, 2012
IMPLEMENTED ON. MARCH 01, 2013
Issued by. Ministry of Industry and Information Technology
Table of Contents
Foreword ... 4 
1 Scope ... 6 
2 Normative references ... 6 
3 Terms, definitions and abbreviations ... 7 
3.1 Terms and definitions ... 7 
3.2 Abbreviations ... 9 
4 Test Conditions ... 10 
4.1 General Conditions ... 10 
4.2 Test Arrangement ... 11 
4.3 Exempted Frequency Bands ... 13 
4.4 Narrow Band Response of Receiver ... 13 
4.5 Continuous Disturbance Measurement Conditions and Arrangement ... 14 
4.6 Immunity Test Conditions and Arrangement ... 14 
5 Performance Evaluation Methods ... 18 
5.1 General ... 18 
5.2 EUT that is able to establish continuous telecom connection ... 18 
5.3 EUT that is unable to establish continuous telecom connection ... 18 
5.4 Applicable methods to evaluate ancillary equipment ... 18 
5.5 Classification of EUT ... 19 
6 Performance criteria ... 19 
6.1 General rules ... 19 
6.2 Performance criteria A (continuous phenomenon) ... 19 
6.3 Performance criteria B (transient phenomenon) ... 20 
6.4 Performance criteria C (discontinuous phenomenon) ... 20 
7 Applicability ... 20 
7.1 Disturbance measurement ... 20 
7.2 Immunity test ... 21 
8 Disturbance measurement method and limited value ... 21 
8.1 Antenna’s port (conducted spurious) ... 21 
8.2 Chassis’ port (radiated spurious) ... 22 
8.3 Chassis’ port of auxiliary equipment ... 23 
8.4 Telecom’s port ... 24 
8.5 DC power input/output port ... 25 
8.6 AC power input/output port ... 26 
8.7 Harmonic wave current (AC power input port) ... 26 
8.8 Voltage fluctuation and flicker (AC power input port) ... 26 
8.9 Transient conducted disturbance (DC power input and output port) ... 26 
9 Test method and grade of immunity ... 27 
9.1 Electrostatic discharge immunity test ... 27 
9.2 Radiation disturbance immunity test (800MHz ~ 2.7GHz) ... 27 
9.3 Electric fast transient pulses immunity test ... 28 
9.4 Surge (impact) immunity test ... 28 
9.5 Conducted disturbance immunity test of radiofrequency field sensitivity .. 29 
9.6 Power frequency magnetic field immunity test ... 29 
9.7 Immunity test of voltage dips, short interruption and voltage change ... 30 
9.8 Transient and surge immunity test (on-board environment) ... 31 
Foreword 
This is the first Part of “Requirements and Measurement Methods of Electromagnetic
Compatibility for 2GHz WCDMA Digital Cellular Mobile Telecommunication System”. The
Standard includes the following parts.
Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz
WCDMA Digital Cellular Mobile Telecommunication System – Part 1. User Equipment
and Ancillary Equipment
And
Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz
WCDMA Digital Cellular Mobile Telecommunication System – Part 2. Base Station and
Ancillary Equipment
This Part replaces YD/T 1595.1-2007 “Requirements and Measurement Methods of
Electromagnetic Compatibility for 2GHz WCDMA Digital Cellular Mobile
Telecommunication System – Part 1. User Equipment and Ancillary Equipment”.
Compared with YD/T 1595.1-2007, this Part has the following main changes.
a) In the normative reference documents, use YD/T 1483 to replace ITU-R SM329 and
GB/T 17626.29 to replace IEC 61000-4-29.
b) Alter the determination methods of narrow-band response.
c) In Chapter 5 of this Part, the version number of YD/T 1312.1 has been changed into
2008.
d) The highest frequency of radiation disturbance test of the ancillary equipment is
6GHz.
e) The highest frequency of radiation immunity test is 2.7GHz.
f) Change the rating and performance criterion of voltage dips and short interruptions
as well as voltage change immunity test.
g) The performance criterion of the surge transient immunity test is unified as
performance criterion B.
This Part mainly references to ETSI EN 301 489-24 “Electromagnetic Compatibility and
Wireless Spectrum, Electromagnetic Compatibility Standard of Wireless Equipment and
Business - Part 24. IMT-2000 Detailed Information of CDMA Direct Spread Spectrum
Mobile and Portable Radio and Ancillary Equipment” and YD/T 1483 “Technical
Requirement and Measurement Method of Spurious Emission of Radio Equipment”. The
Requirements and measurement methods of
electromagnetic compatibility for 2GHz WCDMA digital
cellular mobile telecommunication system –
Part 1. user equipment and ancillary equipment
1    Scope   
This Part specifies the requirements of electromagnetic compatibility for user equipment
and ancillary equipment of 2GHz WCDMA digital cellular mobile telecommunication
system, including limits, performance criterion and measurement methods, etc.
This Part applies to user equipment and ancillary equipment of 2GHz WCDMA digital
cellular mobile telecommunication system.
2    Normative references 
The following documents are indispensable for application of this document. For the dated
documents so quoted, only the dated versions apply to this document. For the undated
documents so quoted, the latest versions (including all modification sheets) apply to this
document.
GB 9254 Information technology equipment - Radio disturbance characteristics - Limits
and methods of measurement
GB 17625.1 Electromagnetic compatibility – Limits - Limits for harmonic current
emissions (equipment input current ≤16 A per phase)
GB 17625.2 Electromagnetic compatibility (EMC) – Limits - Limitation of voltage
changes, voltage fluctuations and flicker in public low-voltage supply systems, for
equipment with rated current ≤16 A per phase and not subject to conditional connection
GB/T 6113.101 Specification for radio disturbance and immunity measuring apparatus
and methods - Part 1-1. Radio disturbance and i......
Related standard:   YD/T 1595.2-2012  YD/T 1592.1-2012
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2019