|
US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YC/T 377-2019: (Cigarettes Determination of ammonia in mainstream smoke Immersion treatment Cambridge filter trap-ion chromatography) Status: Valid YC/T 377: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| YC/T 377-2019 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
(Cigarettes Determination of ammonia in mainstream smoke Immersion treatment Cambridge filter trap-ion chromatography)
| Valid |
YC/T 377-2019
|
| YC/T 377-2017 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Cigarettes--Determination of ammonia in mainstream cigarette smoke--Ion chromatography method
| Obsolete |
YC/T 377-2017
|
| YC/T 377-2010 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Cigarettes. Determination of ammonia in mainstream cigarette smoke. Iom chromatography methd
| Obsolete |
YC/T 377-2010
|
PDF similar to YC/T 377-2019
Basic data | Standard ID | YC/T 377-2019 (YC/T377-2019) | | Description (Translated English) | (Cigarettes Determination of ammonia in mainstream smoke Immersion treatment Cambridge filter trap-ion chromatography) | | Sector / Industry | Tobacco Industry Standard (Recommended) | | Classification of Chinese Standard | X87 | | Classification of International Standard | 65.160 | | Word Count Estimation | 8,894 | | Date of Issue | 2019 | | Date of Implementation | 2020-01-15 | | Issuing agency(ies) | State Tobacco Monopoly Administration |
YC/T 377-2019: (Cigarettes Determination of ammonia in mainstream smoke Immersion treatment Cambridge filter trap-ion chromatography) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Cigarettes Determination of ammonia in mainstream smoke Immersion treatment Cambridge filter trap-ion chromatography)
ICS 65.160
X87
People's Republic of China Tobacco Industry Standard
Replace YC/T 377-2017
Determination of ammonia in mainstream cigarette smoke
Process Cambridge Filter Trap-Ion Chromatography
2019-12-26 released
2020-01-15 implementation
Issued by the State Tobacco Monopoly Administration
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009 and GB/T.20001.4-2015.
This standard replaces YC/T 377-2017 ``Ion Chromatography Method for the Determination of Ammonia in Mainstream Cigarette Smoke'', compared with YC/T 377-2017,
In addition to editorial changes, the main technical changes are as follows.
---Modified the standard name;
---Added the technical index requirements of the impregnation liquid (see 4.5);
---Modified the recommended series of standard working solution concentration range (see 4.7);
---Deleted the technical index requirements and connection methods of the trap and Appendix A and Appendix B (see 5.3 and 6.1.1 of the.2017 edition);
---Modified the smoking content of cigarettes (see 6.1);
--- Deleted the preparation of gas phase absorption liquid and granular phase extract (see 6.2 and 6.3 of the.2017 edition);
---Added the extraction of flue gas samples (see 6.2);
---Modified the content of analysis sample preparation (see 6.3);
---Modified the calculation formula of ammonia release (see 7.3);
---The detection limit and quantification limit of the method have been increased (see Chapter 8);
--- Increased method repeatability and reproducibility (see Chapter 9).
Please note that certain contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents.
This standard was proposed by the State Tobacco Monopoly Administration.
This standard is under the jurisdiction of the National Tobacco Standardization Technical Committee Cigarette Sub-committee (SAC/TC144/SC1).
Drafting organizations of this standard. Shanghai Tobacco Group Co., Ltd., Zhengzhou Tobacco Research Institute, National Tobacco Quality Supervision and Inspection Center, China
Tobacco Corporation Beijing Branch, Zhejiang China Tobacco Industry Co., Ltd., Chongqing China Tobacco Industry Co., Ltd., Guizhou China Tobacco Industry Co., Ltd.
Liability Company, Anhui China Tobacco Industry Co., Ltd., Yunnan Tobacco Quality Supervision and Testing Station, Henan China Tobacco Industry Co., Ltd., Guangxi
China Tobacco Industry Co., Ltd.
The main drafters of this standard. Bai Ruoshi, Lu Nan, Zhou Jun, Liu Xingyu, Du Guorong, Zhao Xiaodong, Qin Yaqiong, Hou Hongwei, Zhang Hongfei, Zhu Lijun,
Tang Jie, Fang Yi, Yu Hang, Shang Mengqi, Peng Lijuan, Chen Xinrui, Shi Chunyun, Xu Gaoyan, Wang Ran, Li Lu, Liu Jian, Wei Jianke, Tian Haiying, Li Guozheng,
Fan Zhong, Xu Aifei, Ma Yanjun, Yi Xiaoli, Zhang Jie, Xu Tongguang, Zheng Xiaoman.
The previous versions of the standard replaced by this standard are as follows.
---YC/T 377-2010, YC/T 377-2017.
Determination of ammonia in mainstream cigarette smoke
Process Cambridge Filter Trap-Ion Chromatography
1 Scope
This standard specifies the method for the determination of ammonia in mainstream cigarette smoke by immersion treatment Cambridge filter trap-ion chromatography.
This standard applies to the determination of ammonia in mainstream cigarette smoke.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.
For undated references, the latest version (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
GB/T 16450 Smoking machine definition and standard conditions for routine analysis
GB/T 19609 Smoking machine for routine analysis of cigarettes for determination of total particulate matter and tar
3 Principle
The Cambridge filter pretreated with the hydrochloric acid-ethanol water immersion solution captures the ammonia in the mainstream smoke and extracts it with a dilute hydrochloric acid solution. Extract
After filtering with 0.45μm water phase filter membrane, it was analyzed by ion chromatograph. Among them, the ammonium ion (NH4) is separated by ion exchange.
The guide detector quantitatively determines and calculates the amount of ammonia released in mainstream cigarette smoke.
4 reagent
Except for special requirements, analytical grade reagents should be used. The water should meet the first-level water regulations in GB/T 6682.
4.1 Hydrochloric acid. 36%~38% (mass fraction).
4.2 Methanesulfonic acid, chromatographically pure.
4.3 NH4 solution standard material [100mg/L, GB W(E)080220].
4.4 Extraction solution. hydrochloric acid solution (0.01mol/L), which should be reconstituted before each experiment.
4.5 Immersion solution. hydrochloric acid-ethanol aqueous solution (0.05mol/L), the volume ratio of ethanol and water is 1.1, and it should be re-prepared before each experiment.
4.6 Mobile phase. methanesulfonic acid solution (0.1mol/L), accurately pipette 6.7mL methanesulfonic acid (4.2) into a 1L volumetric flask, and dilute to the mark with water.
4.7 series of standard working solutions
Respectively pipette a certain volume of NH4 solution standard substance (4.3), dilute with the extract (4.4) to a constant volume. Prepare at least 6 standard jobs
Solution, ready to use. Table 1 is the recommended series of standard working solution concentrations.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YC/T 377-2019_English be delivered?Answer: Upon your order, we will start to translate YC/T 377-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of YC/T 377-2019_English with my colleagues?Answer: Yes. The purchased PDF of YC/T 377-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version YC/T 377-2019?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YC/T 377-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|