Powered by Google www.ChineseStandard.net Database: 189759 (21 Apr 2024)

SN/T 3512-2013 (SNT3512-2013)

SN/T 3512-2013_English: PDF (SNT 3512-2013, SNT3512-2013)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 3512-2013English160 Add to Cart 0--9 seconds. Auto-delivery Determination of tetrabromobisphenol A bis(2, 3-dibromopropyl ether) in electrical and electronic equipment. High performance liquid chromatography Valid SN/T 3512-2013

BASIC DATA
Standard ID SN/T 3512-2013 (SN/T3512-2013)
Description (Translated English) Determination of tetrabromobisphenol A bis(2, 3-dibromopropyl ether) in electrical and electronic equipment. High performance liquid chromatography
Sector / Industry Commodity Inspection Standard (Recommended)
Word Count Estimation 8,892
Quoted Standard GB/T 6682
Drafting Organization Shenzhen Exit Inspection and Quarantine of the PRC
Administrative Organization National Certification and Accreditation Administration
Regulation (derived from) ?AQSIQ About publishing 2013 First Batch 179-items Entry-Exit Inspection and Quarantine industry standard Announcement; Industry-Standard-Filing Announcement 2013 No. 9 (Total No. 165)
Proposing organization Certification and Accreditation Administration of the People's Republic of China
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Summary This standard specifies the electrical and electronic products tetrabromobisphenol -A- double-high performance liquid chromatographic method (2, 3 dibromopropylether)'s. This standard applies to electrical and electronic products, plastic components tetra

Standards related to: SN/T 3512-2013

SN/T 3512-2013
ENTRY-EXIT INSPECTION AND QUARANTINE INDUSTRY
STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA
Determination of tetrabromobisphenol A bis (2,3-
dibromopropyl ether) in electrical and electronic
equipment - High performance liquid chromatography
ISSUED ON: MARCH 01, 2013
IMPLEMENTED ON: SEPTEMBER 16, 2013
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China.
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Normative references ... 4 
3 Method summary ... 4 
4 Reagents and materials ... 4 
5 Instruments and equipment ... 5 
6 Sample preparation ... 5 
7 Analysis steps ... 5 
8 Result calculation ... 7 
9 Report ... 7 
10 Method's linear range, low detection limit, and precision ... 7 
Annex A (informative) Liquid chromatogram of tetrabromobisphenol A bis (2,3-
dibromopropyl ether) standard solution ... 8 
Annex B (informative) Method precision ... 9 
Determination of tetrabromobisphenol A bis (2,3-
dibromopropyl ether) in electrical and electronic
equipment - High performance liquid chromatography
1 Scope
This Standard specifies the determination method of high performance liquid
chromatography of tetrabromobisphenol A bis (2,3-dibromopropyl ether) in
electrical and electronic equipment.
This Standard is applicable to the determination of tetrabromobisphenol A bis
(2,3-dibromopropyl ether) in plastic parts of electrical and electronic equipment.
2 Normative references
The following referenced documents are indispensable for the application of
this document. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any
amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test
methods
3 Method summary
Use toluene-methanol as extraction solvent to conduct microwave extraction of
Tetrabromobisphenol A bis (2, 3-dibromopropyl ether), referred to as BDDP. The
extraction solution is purified. Use high performance liquid chromatography to
analyze.
4 Reagents and materials
Unless otherwise stated, all reagents used are analytical reagents. Water used
is grade one water that complies with GB/T 6682. All solvents for liquid
chromatography mobile phases are chromatographically pure and filtered by a
0.45µm filter membrane.
4.1 Toluene: chromatographically pure.
in an extraction can. Accurately pipette 20mL of toluene + methanol (4.5). Seal
and place in the microwave extraction instrument (5.2). Rise the temperature to
115°C within 5min. Maintain for more than 15min. Cool to room temperature. If
the extraction solution is cloudy and cannot be filtered through a filter, then
accurately pipette 2mL of sample extraction solution. Conduct precipitation
purification treatment according to 7.2. If the extraction solution is clear, then
directly use a 0.46µm nylon filter membrane. Then take part of the filtrate for
chromatographic analysis.
7.2 Precipitation purification
In 2mL of extraction solution that is obtained after processing as 7.1, accurately
add 6mL of n-hexane or methanol. If precipitation occurs in the solution, it shall
conduct centrifuge separation. After removing the serum, set volume to 10mL.
Use a 0.46µm nylon filter membrane to filter, then conduct spectrum analysis.
7.3 Chromatographic conditions
Since the test results depend on the instrument used, it is not possible to give
general parameters for liquid chromatography. The set parameters shall ensure
that the measured component can be effectively separated from other
components during chromatographic determination. The parameters given
below prove to be feasible.
a) Chromatographic column: C18 reverse-phase column [150 × 4.6mm
(inner diameter) × 5μm] or equivalent;
b) Column temperature: 30°C;
c) Isocratic elution: acetonitrile (4.3) + water (95 + 5, V/V);
d) Detection wavelength: 230nm;
e) Injection volume: 10μL;
f) Flow rate: 0.8mL/min.
7.4 Determination
Inject the samples of standard solution (4.8) and sample solution with equal
volume alternately. Determine the nature according to chromatographic
retention time of standard solution. Use external standard method to quantify
based on chromatographic peak area.
Analyze the standard solution according to the above analysis conditions (7.3).
See Annex A for its typical chromatogram.
7.5 Blank test
...