HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

SN/T 2292-2009 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2292-2009English279 Add to Cart 3 days [Need to translate] Determination of lead and cadmium in cosmetics grade talc. Graphite furnace atomic absorption spectrometry method Obsolete SN/T 2292-2009

PDF similar to SN/T 2292-2009


Standard similar to SN/T 2292-2009

SN/T 3321.2   SN/T 3321.1   SN/T 0481.7   SN/T 3975   SN/T 0481.11   SN/T 0481.10   

Basic data

Standard ID SN/T 2292-2009 (SN/T2292-2009)
Description (Translated English) Determination of lead and cadmium in cosmetics grade talc. Graphite furnace atomic absorption spectrometry method
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard D54
Classification of International Standard 73.080
Word Count Estimation 7,787
Date of Issue 2009-02-20
Date of Implementation 2009-09-01
Quoted Standard GB/T 2010; GB/T 6682
Regulation (derived from) National Quality Inspection [2009] No. 67
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the cosmetic grade talc, lead, cadmium graphite furnace atomic absorption method. This standard applies to cosmetic grade talc, lead, cadmium graphite furnace atomic absorption spectrometry.

SN/T 2292-2009: Determination of lead and cadmium in cosmetics grade talc. Graphite furnace atomic absorption spectrometry method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of lead and cadmium in cosmetics grade talc.Graphite furnace atomic absorption spectrometry method Exit inspection and quarantine industry standard book People's Republic of China Cosmetic grade talc detection of lead, cadmium Graphite Furnace Atomic Absorption Spectrometry Posted 2009-02-20 2009-09-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

Appendix A of this standard is an informative annex. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Liaoning Entry-Exit-Entry Inspection and Shanxi People's Republic of China Quarantine Bureau. The main drafters of this standard. Sunzhe Ping, Yang Xiaobing, Huang Daliang, Chen Xinyue, Ren Yuwei. This standard is the first release of the entry-exit inspection and quarantine industry standards. Cosmetic grade talc detection of lead, cadmium Graphite Furnace Atomic Absorption Spectrometry

1 Scope

This standard specifies the cosmetic grade talc of lead and cadmium by graphite furnace atomic absorption spectrometry. This standard applies to cosmetic grade talc lead, cadmium graphite furnace atomic absorption spectrometry.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2010 talc bulk sampling and sample preparation method GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)

3 Method summary

Hot dilute nitric acid solution to extract talc Pb and Cd elements by graphite furnace atomic absorption spectrophotometer, peak area, marked Standard curve quantification.

4 Reagents

Unless otherwise indicated, the reagents are pure class distinctions. Water for the two water GB/T 6682 regulations. 4.1 nitric acid (ρ = 1.42g/mL). 4.2 nitrate solution (0.5mol/L). 31.3mL amount of nitric acid (4.1), diluted with water to 1000mL. 4.3 lead standard stock solution. Direct use of certified standard solution, its concentration of 1000μg/mL. 4.4 cadmium standard stock solution. Direct use of certified standard solution, its concentration of 1000μg/mL. 4.5 lead standard working solution. the lead standard stock solution (4.3) with 0.5mol/L nitrate (4.2) stepwise diluted to 1.0μg/mL. 4.6 Cadmium standard working solution. cadmium standard stock solution (4.4) with 0.5mol/L nitrate (4.2) by serial dilution to 0.010μg/mL. 5. Apparatus 5.1 Atomic absorption spectrophotometer. with graphite furnace atomic devices. 5.2 water bath. 5.3 microwave digestion. 5.4 ultrasonic device. Than 5.5 colorimetric tube. 25mL. 5.6 Analysis of balance. a sense of the amount of 0.1mg.

6 Sample

Samples according to GB/T 2010 were prepared, then milled so that all through 325 mesh, save backup in a desiccator.

7 Procedure

7.1 Sample Weigh 1g ~ 2g (accurate to 0.0001g) sample 3 parts, parallel measurement. Each sample was measured at least twice, whichever results