HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (11 Jan 2025)

SH/T 0404-2008 English PDF (SHT0404-1996, SHT0404-1992)

SH/T 0404-2008_English: PDF (SH/T0404-2008)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SH/T 0404-2008English85 Add to Cart 0--9 seconds. Auto-delivery Test method for light stability of paraffin wax Valid SH/T 0404-2008
SH/T 0404-1996English239 Add to Cart 2 days [Need to translate] (Paraffin Light Stability assays) Obsolete SH/T 0404-1996
SH/T 0404-1992EnglishRFQ ASK 3 days [Need to translate] (Chinese Industry Standard) Obsolete SH/T 0404-1992


BASIC DATA
Standard ID SH/T 0404-2008 (SH/T0404-2008)
Description (Translated English) Test method for light stability of paraffin wax
Sector / Industry Petrochemical Industry Standard (Recommended)
Classification of Chinese Standard E42
Classification of International Standard 75.140
Word Count Estimation 5,548
Date of Issue 2008-04-23
Date of Implementation 2008-10-01
Older Standard (superseded by this standard) SH/T 0404-1996
Quoted Standard NDRC Notice No. 28 of 2008
Drafting Organization China Petroleum & Chemical Corporation Fushun Petrochemical Research Institute
Administrative Organization China Petroleum & Chemical Corporation, Fushun Petrochemical Research Institute
Regulation (derived from) NDRC Notice No. 28 of 2008
Summary This standard specifies the method for measuring paraffin light stability, suitable for food use paraffin wax, fully refined paraffin wax and semi refined paraffin wax.

BASIC DATA
Standard ID SH/T 0404-1996 (SH/T0404-1996)
Description (Translated English) (Paraffin Light Stability assays)
Sector / Industry Petrochemical Industry Standard (Recommended)
Classification of Chinese Standard E42
Classification of International Standard 75.14
Word Count Estimation 6,634
Date of Issue 1996/12/20
Date of Implementation 1997/7/1
Older Standard (superseded by this standard) SH/T 0404-1992
Regulation (derived from) Development & Reform Commission Notice 2008 No. 28

BASIC DATA
Standard ID SH/T 0404-1992 (SH/T0404-1992)
Description (Translated English) (Chinese Industry Standard)
Sector / Industry Petrochemical Industry Standard (Recommended)


SH/T 0404-2008 PETROCHEMICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 75.140 E 42 Replacing SH/T 0404-1996 Test method for light stability of paraffin wax ISSUED ON: APRIL 23, 2008 IMPLEMENTED ON: OCTOBER 01, 2008 Issued by: National Development and Reform Commission of the People's Republic of China Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Method summary ... 4  4 Instruments and materials ... 4  5 Preparation ... 5  6 Test steps ... 5  7 Report ... 6  8 Precision ... 6  Test method for light stability of paraffin wax 1 Scope 1.1 This Standard specifies the method to determine the light stability of paraffin wax. It is applicable to paraffin wax, fully refined paraffin wax and semi-refined paraffin wax for food use. 1.2 This Standard may address certain hazardous materials, equipment and operations. However, it is not intended to advise on all safety issues related thereto. Therefore, before using this Standard, it is the user's responsibility to establish appropriate safety and protection measures, and to develop an applicable management system. 2 Normative references The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrigendum) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies. SH/T 0403, Determination method for paraffin wax colour 3 Method summary Place the specimen dish filled with molten wax into the constant-temperature chamber. Irradiate for 45min under the condition of ultraviolet illuminance of 12.0mW/cm2±0.3mW/cm2 and temperature of 90.0°C±1.0°C. Then measure the color of the specimen. Use color number to indicate the light stability of the paraffin wax. 4 Instruments and materials 4.1 Paraffin light stability tester: temperature-illuminance control unit with digital display, ultraviolet light irradiation heating unit and constant-temperature lighting room. The ultraviolet illumination control range is 12.0mW/cm2 ± 0.3mW/cm2. The temperature control range is 90.0°C±1.0°C. The irradiation time is 45min. The instrument constant-temperature chamber is made of cast aluminum material. The internal is fillet. Air convection is good and easy for temperature control. The upper light-receiving surface is made of transparent quartz glass plate. The absorption of ultraviolet light at the wavelength of 365nm is small. There is a viewing window at the front of the instrument, which is convenient for observing the irradiation of the specimen. 4.2 Ultraviolet high pressure mercury lamp: Power is 375W. UV wavelength is 365nm. The lamp effective arc length is 140mm. NOTE: When the illuminance of the instrument fails to meet the requirements, the lamp tube shall be replaced in time. 4.3 UV light meter: It is used to regularly check whether the illuminance of the light stability tester is within the specified range. It is Type UV-A, with UV-365 probe. Wavelength range is 320nm-400nm. Peak wavelength is 365nm. 4.4 Quartz glass sheet: The diameter is 55mm±2mm. The thickness is 2.5mm ± 0.5mm. 4.5 Specimen dish: It is made of ordinary glass. The inner diameter is 40mm. The height is 21mm. 4.6 Beaker: 100mL. 4.7 Oven (or water bath): Can be heated to 85°C and kept constant-temperature. 4.8 AC stabilized power supply: The working voltage is 220V. The power is not less than 1kW. It is used when the voltage is unstable. 4.9 Instruments and equipment specified in SH/T 0403. 5 Preparation 5.1 Preheat the clean cuvettes, specimen dishes, and quartz glass sheets to 85°C±2°C in an oven (or water bath). 5.2 Put the specimen in the beaker. Heat and melt in an oven (or water bath) at 85°C±2°C. Use qualitative filter paper to filter. 5.3 Open the lamp chamber of the light stability tester. Wipe off fingerprints and dust on the surface of the lamp with absorbent cotton dipped in alcohol. Wipe off the dust on the surface of the quartz glass plate. 5.4 Prepare according to SH/T 0403. 6 Test steps 6.1 Power on the instrument. Press the lighting trigger button. The high-pressure light is on. Monitor the illumination and temperature. ......

Similar standards: SH/T 0398-2007  SH/T 0807-2008  SH/T 0800-2007  
Similar PDFs (Auto-delivered in 9 seconds): SH/T 0404-2008  NB/SH/T 0407-2013  NB/SH/T 0416-2019