Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169759 (Dec 8, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

QB/T 3832-1999

Chinese Standard: 'QB/T 3832-1999'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
QB/T 3832-1999English70 Add to Cart 0--10 minutes. Auto immediate delivery. Evaluation of the corrosion test results of the metal deposits for the light industrial products Valid QB/T 3832-1999

 QB/T 3832-1999 -- Click to view the ACTUAL PDF of this standard (Auto-delivered in 0~10 minutes) In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
Detail Information of QB/T 3832-1999; QB/T3832-1999; QBT 3832-1999; QBT3832-1999
Description (Translated English): Evaluation of the corrosion test results of the metal deposits for the light industrial products
Sector / Industry: Light Industry Industry Standard (Recommended)
Classification of Chinese Standard: Y73; A29
Classification of International Standard: 25.220.01
Word Count Estimation: 5,000
Date of Issue: 11/3/1986
Date of Implementation: 1/12/1986
Older Standard (superseded by this standard): GB 5944-1986
Adopted Standard: ISO 1462-1973, NEQ
Drafting Organization: Shanghai Institute of Light Industry
Administrative Organization: China Daily Hardware Standardization Center
Regulation (derived from): Industry-Science (2010) No.77
Summary: This standard applies to the sample through the neutral salt spray test, acetic acid salt spray test, copper accelerated acetic acid salt spray corrosion test and cream so after sulfur dioxide gas corrosion test specimen rating.

QB/T 3832-1999
QB
LIGHT INDUSTRY STANDARD OF
THE PEOPLE’S REPUBLIC OF CHINA
Y 73
Replacing GB/T 5944-1986
Evaluation of the corrosion test results of the metal
deposits for the light industrial products
轻工产品金属镀层腐蚀试验结果的评价
ISSUED ON. APRIL 21, 1999
IMPLEMENTED ON. APRIL 21, 1999
Issued by. State Bureau of Light Industry
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Rating content ... 4 
3 Assessment area ... 4 
4 Rating method ... 5 
5 Rating instructions ... 6 
Foreword
The previous version of this Standard is GB 5944-1986 Evaluation of the
corrosion test results of the metal deposits for the light industrial products, which
has been transferred to QB/T 3832-1999 via the publication of State Bureau of
Light Industry [1999] No. 12 Document. The content shall remain unchanged.
This Standard was proposed by State Administration of Light Industry Bureau
of Industry Management.
This Standard shall be under the jurisdiction of National Technical Committee
on Daily Hardware of Standardization Administration of China.
The drafting organizations of this Standard. Shanghai Institute of Light Industry,
Shanghai Daily Hardware Industry Research Institute.
Main drafters of this Standard. Zhang Fulin, He Changlin, Dong Zicheng.
Evaluation of the corrosion test results of the metal
deposits for the light industrial products
This Standard specifies the evaluation method for corrosion test results of
plating layer specimen after corrosion test.
This Standard adopts International Standard ISO 1462-1973 Metallic coatings
-- Coatings other than those anodic to the basis metal -- Accelerated corrosion
tests -- Method for the evaluation of the results.
1 Scope
This method is applicable to rating of test specimen after neutral salt spray test,
acetic acid salt spray test, copper salt filling acetic acid salt spray test, corrosion
paste test and sulfur dioxide gas corrosion test.
2 Rating content
This rating method is mainly for the inspection and evaluation in two aspects of
specimen after corrosion test.
2.1 Basic corrosion point refers to the base metal corrosion point penetrating
plating layer of which its size does not include the accompanying rust. Usually,
it is difficult to remove the corrosion point while it is easy to remove rust.
2.2 Plating layer corrosion refers to generic point discoloration of plating layer
excluding darkening. Usually, it is difficult to remove the generic point
discoloration and it has obvious boundary with the whole surface. While it is
easy to wipe darkening bright and it has no obvious boundary with the whole
surface.
3 As......