US$369.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. LY/T 1719-2017: Forestry machinery. Portable fire extinguishers with pneumatic and water spray Status: Valid LY/T 1719: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| LY/T 1719-2017 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Forestry machinery. Portable fire extinguishers with pneumatic and water spray
| Valid |
LY/T 1719-2017
|
| LY/T 1719-2007 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Forestry machinery. Portable-spray for fire-fighting
| Obsolete |
LY/T 1719-2007
|
PDF similar to LY/T 1719-2017
Basic data | Standard ID | LY/T 1719-2017 (LY/T1719-2017) | | Description (Translated English) | Forestry machinery. Portable fire extinguishers with pneumatic and water spray | | Sector / Industry | Forestry Industry Standard (Recommended) | | Classification of Chinese Standard | B95 | | Classification of International Standard | 65.060.80 | | Word Count Estimation | 16,119 | | Date of Issue | 2017-06-05 | | Date of Implementation | 2017-09-01 | | Older Standard (superseded by this standard) | LY/T 1719-2007 | | Quoted Standard | GB/T 191; GB/T 2828.11; GB/T 6388; GB/T 9480; GB/T 10280; GB/T 10283; GB/T 10284; GB/T 13384; GB 26133; GB/T 31202; JB/T 5135.1; JB/T 5135.2; JB/T 5135.3 | | Issuing agency(ies) | State Forestry Administration | | Summary | This standard specifies the terminology and definition of portable feng shui dual-use fire extinguisher (hereinafter referred to as "feng shui fire extinguisher"), which stipulates the model preparation method, technical requirements and test methods, inspection rules, mark, instruction manual, packaging, transportation and storage. This standard applies to small gasoline engine as the driving force of the feng shui fire extinguisher. |
LY/T 1719-2017: Forestry machinery. Portable fire extinguishers with pneumatic and water spray---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Forestry machinery.Portable fire extinguishers with pneumatic and water spray
ICS 65.060.80
B95
People's Republic of China Forestry Industry Standard
Replacing LY/T 1719-2007
Forestry machinery portable Feng Shui dual-purpose fire extinguisher
Published on.2017-06-05
2017-09-01 implementation
State Forestry Administration released
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces LY/T 1719-2007 "Forestry Portable Wind Sprinkler", compared with LY/T 1719-2007
The technical changes are as follows.
--- Revised the name of the standard, modified from the original "forestry machinery portable wind sprinkler" to "forestry machinery portable
Feng Shui dual-purpose fire extinguisher";
---Modified the contents of the normative reference documents (see Chapter 2, Chapter 2 of the.2007 edition);
---Modified the content of the model preparation method (see Chapter 4, Chapter 4 of the.2007 edition);
--- Revised the terms and definitions, adding the terms and definitions of "low intensity fire" and "effective water spray" (see Chapter 3);
--- Removed the requirements and test methods for effective water spray distance (2007 editions 5.3.2.2, 6.2.2.2);
--- Removed the maximum water spray requirements and test methods (2007 version 5.3.2.1, 6.2.2.2);
--- Increased the requirements for effective water injection and test methods (see 5.3.3.1);
--- Removed the requirements and test methods for "fengshui fire extinguishers should have the ability to extinguish medium-sized forest surface fires" (2007 edition)
5.3.2.4, 6.5);
--- Revised the "flip performance" requirements and test methods (see 5.3.4,.2007 version 5.2.7, 6.3);
--- Increased the requirements and test methods for "one-time continuous working time" (see 5.3.6);
--- Revised the requirements and test methods of the water reservoir (see 5.4.2,.2007 edition 5.2.2);
--- Revised the requirements for the harness (see 5.4.6,.2007 version 5.6.5);
--- Increased the "protection of high temperature parts" requirements and test methods (see 5.5.5);
--- Increased requirements and test methods for continuous operation reliability and durability (see 5.6, 5.7);
--- Revised the content of the type test (see 6.3,.2007 version 7.2);
--- Increased the content of third party inspections (see 6.4);
--- Incorporate the content of the original sampling plan and the principle of judgment into the content of third-party inspection (see 6.4,.2007 edition 7.3);
---Modified the main technical parameters of Feng Shui fire extinguisher (see Appendix A,.2007 edition Appendix A);
--- Added the content of the reference (see references).
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This standard is proposed and managed by the National Forestry Machinery Standardization Technical Committee (SAC/TC61).
This standard was drafted. Heilongjiang Zhongyu Longhua Technology Development Co., Ltd., Taizhou Yulin Power Machinery Co., Ltd., Northwest Shaanxi Forest
Machinery Co., Ltd., Yongkang Xinghu Power Machinery Co., Ltd., National Portable Forestry Machinery Quality Supervision and Inspection Center, Heilongjiang Province
Forest Fire Prevention Office of Forestry Department, Jiangsu Linhai Power Machinery Group Co., Ltd., Zhenjiang Wuzhou Machinery Manufacturing Co., Ltd., Shandong Huasheng Zhongtian Machinery Group
Co., Ltd., Heilongjiang Provincial Forest Protection Research Institute.
The main drafters of this standard. Lu Jingqun, Wang Yafei, Sheng Ping, Chen Sanxi, Shang Nianrong, Wang Zhendong, Wu Zhanjie, Zhang Rongshan, Zhong Jianping,
Liu Xiangfeng, Yu Wennan.
The previous versions of the standards replaced by this standard are.
---LY/T 1719-2007.
Forestry machinery portable Feng Shui dual-purpose fire extinguisher
1 Scope
This standard defines the terms and definitions of a portable feng shui fire extinguisher (hereinafter referred to as "fengshui fire extinguisher"), which specifies the model preparation party.
Law, technical requirements and test methods, inspection rules, signs, instructions for use, packaging, transportation and storage.
This standard applies to Feng Shui fire extinguishers powered by small gasoline engines.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 191 packaging storage and transportation icon
GB/T 2828.11 Procedures for the enumeration of samplings - Part 11. Procedures for assessing quality levels
GB/T 6388 transport packaging receipt and delivery mark
GB/T 9480 Agricultural and forestry tractors and machinery, lawn and gardening power machinery manual
GB/T 10280 forestry machinery portable wind extinguisher
GB/T 10283 Determination of vibration of portable wind extinguishers for forestry machinery
GB/T 10284 Determination of noise of portable wind extinguishers for forestry machinery
GB/T 13306 signage
General technical conditions for GB/T 13384 mechanical and electrical product packaging
GB 26133 Limits and measurement methods for emission of pollutants from small ignition engines for non-road mobile machinery (China No.1 and II
stage)
GB/T 31202 Agricultural and forestry machinery and garden machinery hand control and hand-held control machinery hot surface accessibility
Determination
JB/T 5135.1 General purpose small gasoline engine Part 1. Technical conditions
JB/T 5135.2 General purpose small gasoline engines - Part 2
JB/T 5135.3 General purpose small gasoline engines - Part 3. Reliability, endurance test and assessment method
3 Terms and definitions
The following terms and definitions as defined in GB/T 10280 apply to this document.
3.1
Portable feng shui fire extinguisher portablefireextinguisherwithpneumaticandwaterspray
It is carried and operated by a single person. It is powered by a small gasoline engine. It has two independent functions of wind extinguishing and wind sprinkler. It can extinguish low and medium.
Fire extinguishing equipment for strength forest surface fires.
3.2
Low intensity fire low-intensityfire
A fire with a flame height of less than 1.5 m and a fire intensity of less than 3140 kJ/m.
3.3
Medium intensity fire mid-intensityfire
A fire with a flame height of 1.5 m to 3 m and a fire intensity of 3140 kJ/m to 11304 kJ/m.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of LY/T 1719-2017_English be delivered?Answer: Upon your order, we will start to translate LY/T 1719-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of LY/T 1719-2017_English with my colleagues?Answer: Yes. The purchased PDF of LY/T 1719-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version LY/T 1719-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version LY/T 1719-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|