HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

JT/T 1095-2022 English PDF (JTT1095-2016)

JT/T 1095-2022_English: PDF (JT/T1095-2022)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JT/T 1095-2022English245 Add to Cart 0--9 seconds. Auto-delivery Flame resistance of commercial bus interior materials Valid JT/T 1095-2022
JT/T 1095-2016English160 Add to Cart 0--9 seconds. Auto-delivery Flame resistance of commercial bus interior materials Obsolete JT/T 1095-2016


BASIC DATA
Standard ID JT/T 1095-2022 (JT/T1095-2022)
Description (Translated English) Flame resistance of commercial bus interior materials
Sector / Industry Highway & Transportation Industry Standard (Recommended)
Classification of Chinese Standard T09
Date of Issue 2022-01-13
Date of Implementation 2022-04-13
Older Standard (superseded by this standard) JT/T 1095-2016
Quoted Standard JT/T 1095-2016
Regulation (derived from) Ministry of Transport Announcement No. 6 of 2022
Proposing organization Ministry of Transportation
Issuing agency(ies) Ministry of Transportation
Summary This standard specifies the technical requirements, test methods and transitional requirements for the flame retardant properties of interior materials for commercial passenger cars. This standard is applicable to the evaluation of the flame retardant properties of the interior materials of Class B and Class III commercial passenger cars in the M2 and M3 categories. This standard does not apply to school buses.

BASIC DATA
Standard ID JT/T 1095-2016 (JT/T1095-2016)
Description (Translated English) Flame resistance of commercial bus interior materials
Sector / Industry Highway & Transportation Industry Standard (Recommended)
Classification of Chinese Standard T09
Word Count Estimation 10,139
Date of Issue 2016-12-30
Date of Implementation 2017-04-01
Regulation (derived from) Ministry of Transport Notice No.61 of 2016


JT/T 1095-2022 JT TRANSPORTATION INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.020 CCS T 09 Replacing JT/T 1095-2016 Flame resistance of commercial bus interior materials ISSUED ON: JANUARY 13, 2022 IMPLEMENTED ON: APRIL 13, 2022 Issued by: Ministry of Transport of PRC Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Technical requirements ... 7 5 Test method ... 10 6 Transition period requirements for implementation ... 11 Appendix A (Normative) Sampling requirements of test sample ... 12 Appendix B (Normative) Test method and judgment requirements of melting behavior ... 14 Appendix C (Normative) Test method and judgment requirements of capability to repel fuel or lubricant ... 18 References ... 20 Flame resistance of commercial bus interior materials 1 Scope This document specifies the technical requirements, test methods, implementation transition period requirements, for the flame retardant properties of interior materials for commercial bus. This document is applicable to the evaluation of flame retardant properties of grade B and grade III bus interior materials, in category M2 and category M3. This document does not apply to school buses. 2 Normative references The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, for dated references, only the version corresponding to the date applies to this document; for undated references, the latest version (including all amendments) applies to this document. GB/T 2406.2-2009 Plastics - Determination of burning behavior by oxygen index - Part 2: Ambient-temperature test GB/T 5454 Textiles-Burning behavior - Oxygen index method GB 8410 Flammability of automotive interior materials GB/T 8626 Test method of flammability for building materials GB/T 8627 Test method for density of smoke from the burning or decomposition of building materials GB/T 10707 Rubber - Determination of the burning GB/T 11785 Reaction to fire tests for floorings - Determination of the burning behavior using a radiant heat source GB/T 15089 Classification of power-driven vehicles and trailers GB/T 20285 Toxic classification of fire effluents hazard for materials GB/T 32086 Requirement of vertical flammability characteristic and test method for certain category automobile interior material JT/T 1094 Safety specifications for commercial bus 3 Terms and definitions The terms and definitions, as defined in GB/T 15089 and JT/T 1094, as well as the following terms and definitions, apply to this document. 3.1 Oxygen index Under the specified test conditions, when the mixed gas of oxygen and nitrogen at a temperature of 23 °C ± 2 °C is introduced, the minimum oxygen concentration, that can just maintain the combustion of the material, expressed in volume fraction. [Source: GB/T 2406.2-2009, 3.1, modified] 3.2 Density of smoke The measure of the amount of smoke, which is produced by a material, under specified test conditions, expressed by the attenuation of light intensity passing through the smoke. [Source: GB 38262-2019, 3.5] 3.3 Smoke toxicity The degree of damage or injury, which is caused by the toxic and harmful substances in the smoke. [Source: GB 8624-2012, 3.19, modified] 3.4 Melting behavior The characteristics of melting droplets, foaming and other phenomena of material, under the impact of thermal radiation. 3.5 Capability to repel fuel or lubricant The ability of the material to remain non-wetted, under the action of contact with fuel oil. 3.6 Commercial bus interior materials Single material or composite materials, which are used in commercial bus. Note: The interior materials of commercial bus do not include electrical components (such as air-conditioning assembly control switches, wire harnesses, electrical control panels, navigators, radios, DVD modules, driving instrument clusters, and other electrical modules), lamps, steering wheels, airbags (curtain), body damping pads, sandwich panels whose outer layer is made of metal materials and whose inner layer is made of non-metallic materials. 3.7 Single material A homogeneous monolithic material, which is composed of the same material. Note: If different materials are intermittently joined together (such as sewing, welding, riveting), this material is not considered to be a composite material, BUT each material is a single material. [Source: GB 8410-2006, 2.3, modified] 3.8 Composite material The material, which is formed by two or more layers of similar or different materials, the surfaces of which are fully and tightly bonded together by different methods such as welding and bonding. [Source: GB 8410-2006, 2.2, modified] 4 Technical requirements 4.1 Material classification The interior materials of commercial bus shall be classified according to the applied materials in Table 1, included interior materials, used parts. 4.2.2 The size of the interior material shall be measured according to the largest rectangle, which is covered by the projection of its components assembled in the vehicle facing the occupant direction. 4.2.3 Interior parts, that meet the following minimum size requirements, shall be tested for flame retardancy: a) Interior parts, which have a width not less than 100 mm and a length not less than 356 mm; b) The same type of interior parts used inside the vehicle, which has a width of not less than 100 mm, the length of less than 356 mm but not less than 138 mm, meanwhile has an accumulative use length of not less than 1000 mm; c) The same type of interior parts used inside the vehicle, which has a width of not less than 100 mm but not less than 20 mm, the length of less than 356 mm, meanwhile has an accumulative use length of not less than 2000 mm. 4.2.4 If the interior parts contain cavities, meanwhile the parts without cavities do not meet the minimum size requirements, the test can be exempted. 4.2.5 When the interior parts can be separated into single material and composite material, the test results of the separated materials shall be judged according to the requirements in Table 2. Example: If the side panel is composed of PVC skin wrapped PP sheet, the PVC skin after splitting shall be judged according to the technical requirements of "Others" in Item 5 "Leather material" of Table 2; the PP sheet shall be judged according to the technical requirements of Item 1 "Interior panel" in Table 2. 4.2.6 When interior materials of the same material, process, thickness, manufacturer are used in multiple parts, the technical requirements shall cover the maximum limit requirements for all parts of the interior material. 5 Test method 5.1 Sampling of test samples Sampling shall be carried out, according to the provisions of Appendix A. 5.2 Horizontal combustion Carry out the test, according to the provisions of GB 8410. 5.3 Vertical combustion Carry out the test, according to the provisions of GB/T 32086. 5.4 Oxygen index 5.4.1 Textile materials shall be tested, according to the provisions of GB/T 5454. 5.4.2 Rubber materials shall be tested, according to the provisions of GB/T 10707. 5.4.3 Plastics, fiber-reinforced plastics, leather materials and other materials shall be tested, according to the provisions of GB/T 2406.2. 5.4.4 To carry out the oxygen index test of the interior material, it may use the simplified method C in Chapter 10 of GB/T 2406.2-2009, meanwhile explain it in the test report. 5.5 Smoke density Carry out the test, according to the provisions of GB/T 8627. The test result is expressed by the smoke density level. 5.6 Combustion performance level Carry out the test, according to the provisions of GB/T 11785 and GB/T 8626. 5.7 Levels of smoke production characteristics Carry out the test, according to the provisions of GB/T 11785. 5.8 Smoke toxicity level Carry out the test, according to the provisions of GB/T 20285. 5.9 Melting properties Carry out the test, according to the provisions of Appendix B. 5.10 Capability to repel fuel or lubricant Carry out the test, according to the provisions of Appendix C. 6 Transition period requirements for implementation Models that have obtained type approval will be implemented on the 13th month, from the date of implementation of this document. specimen support shall be a metal ring. B.1.3 Stainless steel grid The structure of the stainless steel grid is as shown in Figure B.1. The size shall meet the following requirements: a) Mesh size: A square with a side length of 2.1 mm; b) Diameter of stainless steel wire: 0.7 mm. B.1.4 Containers B.1.4.1 The container is a cylindrical tube, which has an inner diameter of 118 mm and a depth of 12 mm. See Figure B.1 for the structure. Absorbent cotton shall be laid flat in the container. B.1.4.2 The electric heater is installed on the top of the support, with the radiating surface facing down, meanwhile the radiating surface shall be able to completely cover the surface of the specimen. The electric heater shall have a corresponding displacement device, to realize slow removal and reset; the electric heater, specimen holder and container shall be kept on the same vertical plane. B.2 Electric heater B.2.1 Confirmation of electric heater Electric heaters shall be verified by a pyranometer with a measuring range not exceeding 10 W/cm2. The irradiated surface of the pyranometer is round and flat, which has a surface diameter of not more than 10 mm, meanwhile it is coated with a heat- resistant matte black coating. The bolometer shall be placed in a circular polished metal panel, which has a diameter of 25 mm. The bolometer shall have a water cooling system; the bolometer accuracy shall not exceed ±3%. B.2.2 Validation period The power of the electric heater is 3 W/cm2; it shall be confirmed once it has been used for 50 hours. If the power deviation is greater than 0.06 W/cm2 during confirmation, the electric heater shall be readjusted and confirmed. B.2.3 Validation process The instrument is placed in an environment which has no air circulation (air velocity does not exceed 0.2 m/s). Place the bolometer at the position, where the specimen is placed in the instrument, to ensure that the bolometer is located in the center of the radiation surface. Turn on the power and control the input power of the electric heater to 3 W/cm2 as required. If the bolometer shows 3 W/cm2 continuously within 5 minutes without adjusting the power, the electric heater is considered to be stable. B.3 Specimen B.3.1 Specimen size B.3.1.1 The size of the specimen is 70 mm in length, 70 mm in width, no more than 13 mm in thickness. B.3.1.2 When the thickness of the interior material exceeds 13 mm: a) When the interior material is a single material, use mechanical methods to cut from the non-exposed surface, so that the thickness of the specimen including the exposed surface is 13 mm, AND the number of specimens is 4; b) When the interior material is a composite material, mechanical methods shall be used to sample from the front and back. The front sampling shall be cut from the non-exposed surface, so that the thickness of the specimen including the exposed surface is 13 mm; the reverse sampling shall be cut from the exposed surface, so that the thickness of the specimen including the non-exposed surface is 13 mm. The number of specimens is 4 on the front and 4 on the back. B.3.1.3 Before the test, each specimen shall be weighed and recorded; the mass of each specimen shall not be less than 2 g. If the mass is less than 2 g, the mass of the specimen can be made to meet the test requirements by stacking; meanwhile the mass of the specimen after stacking can be recorded. B.3.2 Specimen pretreatment Before the test, the specimen shall be placed at least 24 h, under the conditions of temperature 23 °C ± 2 °C and relative humidity 50% ± 5%. B.3.3 Absorbent cotton pretreatment Before the test, the absorbent cotton shall be placed for at least 24 hours at a temperature of 23 °C ± 2 °C and a relative humidity of not more than 20%. B.4 Test method B.4.1 Place the specimen on the support. Ensure that the distance -- between the specimen on the support and the radiation surface is 30 mm. At the same time, adjust the container containing the absorbent cotton, to keep the distance -- between the top of the absorbent cotton and the bottom of the support grid -- at 300 mm. B.4.2 Before the test, first rotate the electric heater away from the specimen, to ensure that the specimen is not radiated; then turn on the electric heater. When the radiation power reaches 3 W/cm2, set the test time for 5 minutes. Then rotate the electric heater, to directly above the specimen. Start timekeeping. B.4.3 During the test, if the specimen does not burn within 5 minutes, the test ends. If The test liquid shall be No.0 diesel. C.2.3 Specimen pretreatment The specimen is placed at a temperature of 23 °C ± 2 °C and a relative humidity of 50% ± 5%, for 24 hours. Then the test is carried out immediately. C.3 Test environment The entire test process shall be carried out in an environment with a temperature of 23 °C ± 2 °C and a relative humidity of 50% ± 5%. C.4 Test method C.4.1 The specimen shall be weighed before the test. C.4.2 Place the exposed surface of the specimen upwards, on the base of the equipment. Place the metal cylinder at the center of the specimen. Apply sufficient pressure through the stud, to make the metal cylinder tightly bonded to the specimen. C.4.3 Inject the test liquid into the metal cylinder, to a height of 20 mm. Then let it stand for 24 hours. The liquid shall not leak during the test. C.4.4 After the test, take out the test liquid first. Then loosen the stud, to remove the metal cylinder. Finally take out the specimen. If a residue of the test liquid is found on the specimen, it shall be removed without compressing the specimen. The specimen shall be weighed, after removing the residue. C.5 Result determination If the mass of the specimen, after the test, increases by no more than 1 g, as compared with the mass of the specimen, before the test, it is judged as qualified. ......


JT/T 1095-2016 JT TRANSPORTATION INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.020 T 09 Record No.. Flame Resistance of Commercial Bus Interior Materials ISSUED ON. DECEMBER 30, 2016 IMPLEMENTED ON. APRIL 01, 2017 Issued by. Ministry of Transport of the People’s Republic of China Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Terms and Definitions ... 5 4 Technical Requirements ... 6 5 Test Methods ... 8 6 Transition Period Requirements for Implementation ... 9 Appendix A (Normative) Sampling Requirements for Test Sample ... 10 Bibliography ... 12 Flame Resistance of Commercial Bus Interior Materials 1 Scope This Standard specifies the technical requirements and test methods for the flame resistance of commercial bus interior materials. This Standard is applicable to the evaluation on the flame resistance of the commercial bus interior materials. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB/T 28046.2-2011 Road Vehicles - Environmental Conditions and Testing for Electrical and Electronic Equipment - Part 2. Electrical Loads GB/T 5454 Textiles - Burning Behavior - Oxygen Index Method GB 8410 Flammability of Automotive Interior Materials GB/T 8626 Test Method of Flammability for Building Materials GB/T 8627 Test Method for Density of Smoke from the Burning or Decomposition of Building Materials GB/T 10707 Rubber - Determination of the Burning GB/T 11785 Reaction to Fire Tests for Floorings—Determination of the Burning Behavior Using a Radiant Heat Source GB/T 20285 Toxic Classification of Fire Effluents Hazard for Materials GB 32086 Requirement of Vertical Flammability Characteristic and Test Method for Certain Category Automobile Interior Material 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply. 3.1 Commercial bus The bus used for commercially transporting the passenger. NOTE. rewrite JT/T 325-2013, definition 3.1. 3.2 Oxygen index The minimum oxygen concentration, under the specified test conditions, that can exactly right maintain the material combustion, when the oxygen and nitrogen mixed gas is injected at 23°C±2°C; expressed by the volume fraction. NOTE. rewrite GB/T 2406.2-2009, definition 3.1. 3.3 Smoke density The magnitude of the amount of smoke emitted by a material under specified test conditions; expressed by amount of light intensity attenuation for through-smoke. 3.4 Smoke toxicity The degree of damage or injury caused by toxic and hazardous substances in the sample. 3.5 Commercial bus interior materials The single material or composite material used by the interior of the commercial bus. NOTE. The commercial bus interior materials include interior panels, flooring materials, elastic cushion materials, textile materials, leather materials, plastic materials for seats, insulation materials, heat insulation materials, noise reduction materials, vibration damping materials, joining materials, other non-metallic interior materials; excluding electrical components (such as air conditioning assembly control switches, wiring harnesses, electrical control panels, navigators, radios, DVD modules, driving instruction clusters, etc.), lamps, steering wheels, airbags (curtains), body damping pad, and the sandwich plates with outer layer of metallic materials and inner layer of non-metallic materials. 3.6 Single material The uniform monolithic materials consisting of the same materials. NOTE 1. If different materials are intermittently connected together (for example, sewing, welding, riveting), and such materials are not considered to be composite materials; then each 5.3.2 If the interior material consists of a variety of materials, it shall be split into single material and composite material; separately test them as per the requirements of 5.3.1. 5.4 Smoke density The test methods for smoke density shall be carried out as per GB/T 8627; the test results shall be determined by the smoke density level. 5.5 Oxygen index 5.5.1 The textile material shall be tested as specified in GB/T 5454. 5.5.2 The rubber material shall be tested as specified in GB/T 10707. 5.5.3 Plastic, fiber reinforced plastic and leather materials shall be tested as specified in GB/T 2406.2. 5.5.4 If the interior material consists of a variety of materials, it shall be split into single material and composite material; separately test them as per the requirements of 5.5.1~5.5.3. 5.5.5 When taking the oxygen index test of the interior, the brief method C specified in Clause 10 of GB/T 2406.2-2009; which shall be indicated in the test report. 5.6 Burning property level The floor covering in the flooring material shall be tested as specified in GB/T 11785 and GB/T 8626. 5.7 Smoke-generating property level The floor covering in flooring material shall be tested as specified in GB/T 11785. 5.8 Smoke toxicity level The floor covering of the flooring material shall be tested as specified GB/T 20285. 6 Transition Period Requirements for Implementation The product that has been licensed or certified shall be implemented at the 13th month since the date of implementation for this Standard. ......

Similar standards: JT/T 1241-2019  JT/T 999-2015  
Similar PDFs (Auto-delivered in 9 seconds): JT/T 1095-2022  JT/T 1095-2016  QC/T 1156-2021