Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Dec 7, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

JJG 22-2014

Chinese Standard: 'JJG 22-2014'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
JJG 22-2014English529 Add to Cart Days<=4 Verification Regulation of Internal Micrometers Valid JJG 22-2014
JJG 22-2014Chinese24 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

 JJG 22-2014 -- Click to view similar PDF/Books...  
Detail Information of JJG 22-2014; JJG22-2014
Description (Translated English): Metrology & Measurement Industry Standard
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A52
Classification of International Standard: 17.040
Word Count Estimation: 23,277
Date of Issue: 11/17/2014
Date of Implementation: 5/17/2015
Older Standard (superseded by this standard): JJG 22-2003
Quoted Standard: GB/T 8177; GB/T 22093-2008
Drafting Organization: Mudanjiang City of Quality and Technical Supervision and Testing Center; ; Suzhou McCrone measurement technology Co., Ltd.; Liaoning Provincial Institute of Metrology Harbin Measuring & Cutting Tool Group Co., Ltd; verification test hospital in Heilongjia
Administrative Organization: National Geometric Engineering Parameter Measurement Technical Committee
Regulation (derived from): The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125
Issuing agency(ies): State Administration of Quality Supervision, Inspection and Quarantine
Summary: This Standard applies to: a value of 0.01 mm or indexing resolution of 0.001 mm, micrometer indication range 13 mm, 25 mm, 50 mm, measuring not more than the upper limit of the inner diameter of 6 000mm extension bar micrometer, a single shot point inside


JJG 22-2014
Verification Regulation of Internal Micrometers
State verification procedures People's Republic of China
Inside micrometer
InternalMicrometers
Issued on: 2014-11-17
2015-05-17 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Micrometer diameter test procedures
VerificationRegulationof
InternalMicrometers
􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣
􀥣
􀥣
􀥣
􀥣
􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣􀥣
􀥣
􀥣
􀥣
􀥣
􀧣 􀧣
􀧣􀧣
Replacing JJG 22-2003
NFP: National Engineering Geometrical Parameters Measurement Technology Committee
Main drafting unit: Heilongjiang Provincial Academy of verification test
Harbin Measuring & Cutting Tool Group Co., Ltd.
Mudanjiang City of Quality and Technical Supervision and Testing Center
Participated in the drafting: Suzhou McCrone measurement technology Co., Ltd.
Liaoning Provincial Institute of Metrology
This procedure works commissioned by the National geometric parameter measurement technology committee responsible for the interpretation
The main drafters of this procedure:
Han Zhengyang (Heilongjiang Provincial Academy of verification test)
Zhang Haibo (Heilongjiang Provincial Academy of verification test)
Dong Yuwen (Harbin Measuring & Cutting Tool Group Co., Ltd.)
In Wenlong (Mudanjiang City of Quality and Technical Supervision and Inspection Center)
Drafters participate:
Huang Xiaobin (Suzhou McCrone measurement technology Co., Ltd.)
Liu Ying (Heilongjiang Academy of verification test)
Na Liu (Liaoning Provincial Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 Overview (1)
4 metering performance requirements (2)
4.1 radius of curvature of the probe measuring surface (2)
4.2 measuring surface roughness of the surface (2)
4.3 groove width and width difference (2)
4.4 differential cylinder tapered edges fixed to the casing from the surface of the engraved lines (2)
The relative positions of end faces of the differential cylinder 4.5 mm tapered sleeve is fixed in the groove (2)
Shows the change (2) value of 4.6 micrometer locking device locking and release time
4.7 Value drift (2)
4.8 digital value Consistency of Readings and differential cylinder (2)
4.9 Indication error (2)
4.10 rigid cause a change in the length dimension (3)
4.11 proofreading caliper indication error and two parallel face (3)
5 General technical requirements (4)
5.1 Appearance (4)
5.2 Interaction of each part (4)
6 Control of measuring instruments (4)
6.1 Verification condition (4)
6.2 test items and test equipment (4)
6.3 Verification Methods (5)
6.4 test result processing (8)
6.5 test cycle (8)
Appendix A micrometer head and the ground pole combinations Examples (9)
Appendix B inside micrometer indication error of measurement uncertainty evaluation (10)
Appendix C measuring machine with laser interferometer measurement indication error description (13)
Appendix D calibration certificate/test results in the notice page and format (14)
introduction
JJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement
Definitions ", JJF1059.1-2012" Evaluation and Expression of Uncertainty in Measurement ", JJG 22-2003" inside micrometer inspection
Setting rules "(hereinafter referred to as the original regulations) constitute the basis of technical regulations of the series metering regulations revision.
This procedure is JJG 22-2003 amendments. Compared with JJG 22-2003, in addition to editorial changes outside the main technical
Surgery changes are as follows:
--- According to GB/T 22093-2008 "electronic digital micrometer diameter" and GB/T 8177-2004 "points
Inside micrometer "newly added electronic digital display device" consistent value drift "and" digital value and differential cylinder readings
Of "verification project, while increasing technical requirements and test methods corresponding to the project.
--- According to GB/T 8177-2004 "points inside micrometer" Edit "groove width and width difference" Without
Fixed tube diameter with the same requirements.
--- Edit "change indication error indication micrometer head and locking device locking and release time" is shown in the micrometer head
Error requirements.
--- Edit "micrometer head and the ground pole combination of size" to "indication error", do not use the checking of inspection.
--- According to GB/T 8177-2004 "points inside micrometer" modified "show error" and "rigid lead
From the length of the change in size, "the technical requirements.
The previous versions of this Recommendation published case:
JJG 22-2003
JJG 22-1991
JJG 22-1981
JJG 22-75
Micrometer diameter test procedures
1 Scope
The order applies to: indexing is 0.01mm or resolution of 0.001mm, micrometer range indication
13mm, 25mm, 50mm, measurement limit of not more than 6000mm of connecting rod inside micrometer, a single shot point inside
Micrometer, digital micrometer diameter connecting rod and several significant single shot inside micrometer (hereinafter referred to as micrometer diameter) of the first seizure
Set, and use the subsequent verification check.
2. References
This procedure references the following documents:
GB/T 8177 two micrometer diameter
GB/T 22093-2008 electronic digital micrometer diameter
For dated references, only the dated edition applies to this procedure; undated reference documents
Member, the latest edition (including any amendments) applies to this procedure.
3 Overview
Inside micrometer for measuring the inner diameter of the workpiece, the groove width and the distance between the two inner surfaces. The main structure
In the form of Arbors were inside micrometer (see Figure 1), a single shot inside micrometer (see Figure 2), digital Post-point inside
Feet (see Figure 3), digital single shot inside micrometer (see Figure 4).
Figure 1 connecting rod inside micrometer schematic
1 - Fixed probe; 2- Take pole; 3 - locking device; 4- micrometer; 5- fixed casing; 6- differential cylinder; 7- adjustable probe
2 single rod inside micrometer schematic
1 - Fixed probe; 2- locking device; 3- fixed casing; 4- differential cylinder; 5- adjustable probe
Related standard:   JJG 24-2016  JJG 30-2012
   
 