HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

JJF 1424-2013 PDF English

US$150.00 · In stock · Download in 9 seconds
JJF 1424-2013: Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
JJF 1424-2013English150 Add to Cart 0-9 seconds. Auto-delivery Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: JJF 1424-2013
      

Similar standards

JJF 1441   JJF 1363   JJF 1425   

JJF 1424-2013: Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJF1424-2013
JJF National Metrology Technical Specifications of the People's Republic of China Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers Issued on: AUGUST 15, 2013 Implemented on: NOVEMBER 15, 2013 Released by. State Administration for Quality Supervision and Inspection and Quarantine Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers Administration organization. National Environmental Chemical Metrology Technical Committee Drafting organization. Shanghai Metrology Test Technology Research Institute Jiangsu Institute of Metrology Shanghai INESA Scientific Instrument Co., Ltd. National Environmental Chemical Metrology Technical Committee is entrusted to interpret this regulation Main drafters of this specification. Ding Min (Shanghai Metrology Test Technology Research Institute) Gong Feiyan (Shanghai Metrology Test Technology Research Institute) Xie Luyun (Shanghai Metrology Test Technology Research Institute) Participating drafters. Cai Yeqiang (Jiangsu Institute of Metrology) Xing Jinjing (Jiangsu Institute of Metrology) Wang Qiaomei (Shanghai INESA Scientific Instrument Co., Ltd.)

Table of Contents

1 Scope ... 6 2 Reference ... 6 3 General ... 6 4 Technical data and prototype that shall be submitted by application organization ... 6 4.1 Technical Information ... 6 4.2 Test prototype ... 7 5 Requirements of legal system management ... 7 5.1 Requirements of measurement unit ... 7 5.2 Accuracy requirements (maximum allowable error) ... 7 5.3 Requirements of metrological legislation marks and instruments identifications ... 7 5.4 Design requirements of external structure ... 8 5.5 Other requirement ... 8 6 Metrological requirements ... 8 7 General technical requirements ... 8 7.1 Appearance ... 8 7.2 Adaptability of power voltage ... 9 7.3 Safety requirements ... 9 7.4 Environmental test ... 9 8 Schedule of pattern evaluation items ... 10 9 Test methods and conditions for test items ... 11 9.1 Metrological requirements ... 11 9.2 General technical requirements ... 15 10 Determination and treatment on results of pattern evaluation ... 24 11 Primitive recording format of pattern evaluation ... 24 Appendix A ... 25 Primitive Recording Format of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers ... 25 Foreword This program of pattern evaluation is drafted and based on JJF 1016 ‘The Rules for Drafting Program of Pattern Evaluation of Measuring Instruments’, JJF 1015 ‘General Norm for Pattern Evaluation and Pattern Approval of Measuring Instruments’, and JJF 1001 ‘General Terms in Metrology and Their Definitions’. The technical index of this program of pattern evaluation has referred to JJG 631-2013 ‘Ammonia- Nitrogen Automatic Analyzers’, GB/T11606-2007 ‘Methods of Environmental Test for Analytical Instruments’, and other technical regulations and standards. This is the first release. Program of Pattern Evaluation of Ammonia-Nitrogen Automatic Analyzers

1 Scope

This program of pattern evaluation is applicable to the pattern evaluation of the Ammonia-Nitrogen automatic analyzer that are based on the electrode method and spectrophotometric method.

2 Reference

JJG 631-2013 Ammonia and Nitrogen Automatic Analyzer GB/T 11606-2007 Analyzer Instrument Environmental Testing Method The articles in the above documents, through the reference of this program, become the articles of this program. For documents indicated with date, all the subsequent modifications (excluding the corrigendum) or revisions are not applicable to this program, however, the parties who have entered into agreement based on this program are encouraged to investigate whether the latest version of these documents can be applied. For all cited documents without date, their latest versions are applicable to this program.

3 General

Ammonia-Nitrogen automatic analyzer can continuously monitor the Ammonia-Nitrogen concentration of the water body such as underground water, surface water and industrial wastewater. Measurement methods for Ammonia-Nitrogen automatic analyzer (hereinafter referred to as instrument) include spectrophotometric method and electrode method. Spectrophotometric method includes salicylic acid spectrophotometric method and Nessler reagent spectrophotometric method etc. The principle is that ammonia or ammonium ion under free state in the water sample will be color-developed after reacting with indicator. The absorbance and Ammonia-Nitrogen content of the solution at specified wave length are in direct proportion. So the quantitative analysis for Ammonia-Nitrogen in the water sample is realized. Electrode method includes air-sensitive electrode method and ion selective electrode method. The Ammonia-Nitrogen content in the water sample will be obtained through measurement of electrode potential. Instrument mainly consists of sampling unit, water sample treatment unit, detection unit, data collection and processing unit, display, transmission unit, and other units.

4 Technical data and prototype that shall be submitted by application organization

4.1 Technical Information a) Prototype photo; b) Product standard (containing testing method); c) General assembly drawing, circuit diagram and main parts drawing; d) Operating manuals; 9.2.9.2 Test conditions In accordance with the requirements in Table 3 of 7.4.4 9.2.9.3 Testing equipment Within the working space of test chamber (room), the temperature conditions specified in Table 3 shall be able to be provided. Permissible error is ±2°C. Air circulation can be forced to keep the temperature uniformity. In order to limit the radiation effect, the temperature difference between the temperature of each section of inner wall of test chamber (room) and the specified test temperature shall not exceed 3% (calculated by thermodynamic temperature ). And the instrument shall not be affected by the direct radiation of any above heated or cooled elements which are not meeting the above requirements. The volume of the test chamber (room) shall be 3 times larger than the volume of the instrument. 9.2.9.4 Test procedures a) Put the instrument to the normal position in the test chamber. The temperature of the test chamber at this time is consistent with the instrument temperature; b) Change the temperature of test chamber to the stipulated value at the rate ≤ 1°C/min. Power on. Maintain for 8 hours; c) Increase the temperature of test chamber to the stipulated value at the rate ≤ 1°C/min to the initial temperature after reaching the test time of duration. Recover for 24h under normal test conditions. 9.2.9.5 Qualification judgment The result in accordance with requirements of 7.4.4 is deemed as qualified. 9.2.10 High temperature storage test 9.2.10.1 Experimental purpose Check the adaptability of the instrument with intact packing under low temperature condition in transportation, storage during delivery. 9.2.10.2 Test conditions In accordance with the requirements in Table 3 of 7.4.4. 9.2.10.3 Testing equipment Within the working space of test chamber (room), the temperature conditions specified in Table 3 shall be able to be provided. Permissible error is ±2°C. Air circulation can be forced to keep the temperature uniformity. In order to limit the radiation effect, the temperature difference BETWEEN the temperature of each section of inner wall of test chamber (room) AND the specified test 15. Alternating damp heat test Starting time of test. ___YY ___MM ___DD ___HH ___MM Ending time of test. ___YY ___MM ___DD... ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of JJF 1424-2013 be delivered?

Answer: The full copy PDF of English version of JJF 1424-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJF 1424-2013_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1424-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- JJF 1424-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of JJF 1424-2013?

A step-by-step guide to download PDF of JJF 1424-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJF 1424-2013".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9