HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (11 Jan 2025)

JB/T 8734.4-2016 English PDF (JBT8734.4-2012, JBT8734.4-1998)

JB/T 8734.4-2016_English: PDF (JB/T8734.4-2016)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JB/T 8734.4-2016English259 Add to Cart 3 days [Need to translate] Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipment Valid JB/T 8734.4-2016
JB/T 8734.4-2012English90 Add to Cart 0--9 seconds. Auto-delivery Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750 V - Part 4: Insulated wires for internal wiring of equipment Obsolete JB/T 8734.4-2012
JB/T 8734.4-1998English239 Add to Cart 2 days [Need to translate] Polyvinyl chloride insulatcd cables and wires and cords of rated voltages up to and including 450/750V. Part 4: Insulated wires for internal wiring of equipment Obsolete JB/T 8734.4-1998


BASIC DATA
Standard ID JB/T 8734.4-2016 (JB/T8734.4-2016)
Description (Translated English) Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4: Insulated wires for internal wiring of equipment
Sector / Industry Mechanical & Machinery Industry Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 11,183
Date of Issue 2016-04-05
Date of Implementation 2016-09-01
Older Standard (superseded by this standard) JB/T 8734.4-2012
Regulation (derived from) The Ministry of Industry and Notice No. 2016 in 2016; industry standard filing notice 2016 No. 8 (total No. 200)
Summary This standard specifies the type, specifications, technical requirements and inspection of the installation wires.

BASIC DATA
Standard ID JB/T 8734.4-2012 (JB/T8734.4-2012)
Description (Translated English) Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750 V - Part 4: Insulated wires for internal wiring of equipment
Sector / Industry Mechanical & Machinery Industry Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 11,170
Date of Issue 2012-05-24
Date of Implementation 2012-11-01
Older Standard (superseded by this standard) JB/T 8734.4-1998
Quoted Standard GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.13-2008; GB/T 2951.14-2008; GB/T 2951.31-2008; GB/T 2951.32-2008; GB/T 5023.2-2008; GB/T 18380.12-2008; GB/T 18380.22-2008; JB/T 8734.1-2012
Drafting Organization Shanghai Electric Cable Research Institute
Administrative Organization National Standardization Technical Committee of wire and cable
Regulation (derived from) Ministry of Industry and Information Technology Bulletin 2012 No. 20; industry standard filing Notice 2012 No. 7 (No. 151 overall)
Summary This standard specifies the use of wire installation features, models, specifications, technical requirements and testing. This part is suitable for AC rated voltage Uo/U is 300/300 V and below electrical, instrumentation and electronic equipment and auto

BASIC DATA
Standard ID JB/T 8734.4-1998 (JB/T8734.4-1998)
Description (Translated English) Polyvinyl chloride insulatcd cables and wires and cords of rated voltages up to and including 450/750V. Part 4: Insulated wires for internal wiring of equipment
Sector / Industry Mechanical & Machinery Industry Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 6,647
Date of Issue 1998/5/28
Date of Implementation 1998/11/1
Older Standard (superseded by this standard) GB 5023.4-1986
Quoted Standard GB/T 2951-1997; GB 5023.2-1997; GB 12666.2-1990; JB 8734.1-1998
Drafting Organization Shanghai Electric Cable Research Institute Ministry of Machinery Industry
Administrative Organization National Standardization Technical Committee of wires and cables
Regulation (derived from) Ministry of Industry and Information Technology Notice 2012 No. 20; Industry Standard Filing Notice 2012 No. 7 (Overall No. 151)
Summary This standard specifies the installation of wire types, specifications, technical requirements and testing. This standard applies to AC rated voltage U0/U is 300/300V and below appliances, instrumentation and automation equipment internal wiring installation of PVC insulated copper wire.


JB/T  8723.4‐2012  Translated English of Chinese Standard. JB/T8723.4‐2012  JB ICS 29.060.20 K 13 Record No.. 36479-2012 INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing JB/T 8734.4-1998 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4. Insulated wires for internal wiring of equipment ISSUED ON. MAY 24, 2012 IMPLEMENTED ON. NOVEMBER 01, 2012 Issued by. Ministry of Industry and Information Technology of the People’s Republic of China Table of Contents Foreword ... 3  1  Scope ... 5  2  Normative references ... 5  3  Operational characteristics ... 6  4  Models ... 6  5  Specifications ... 7  6  Technical requirements ... 7  6.1  General principles ... 7  6.2  Conductor ... 8  6.3  Insulation ... 8  6.4  Insulated core cabling ... 8  6.5  Sheath ... 8  6.6  Appearance dimension ... 8  7  Inspection ... 9  Foreword JB/T 8734 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V consists of 6 parts as follows. — Part 1. General requirements; — Part 2. Insulated cables and wires for fixed wiring; — Part 3. Cords and cables for connecting; — Part 4. Insulated wires for internal wiring of equipment; — Part 5. Screened wires; — Part 6. Lift cables. This is part 4 of JB/T 8734. This part was drafted according to the rules specified in GB/T 1.1-2009 This part will replace JB/T 8734.4-1998 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V Part 4. Insulated wires for internal wiring of equipment. Compared with JB/T 8734.4-1998, main technical changes of this part are as follows. — Change the chapter name and relevant reference standards in Normative References (see Chapter 2; Chapter 2 in 1998 edition); — Add the specifications and corresponding requirements for AVVR cables’ conductor (see Table 2 and Table 7). This part was proposed by China Machinery Industry Federation. This part shall be under the jurisdiction of National Technical Committee (SAC/TC213) on Wire and Cables of Standardization Administration of China. The responsible drafting organization of this part. Shanghai Cable Research Institute. The participating drafting organizations of this part. Guangzhou Cable Factory, Hunan Jinbei Cable Co., Ltd, Kunming Cables Co., Ltd, Baosheng Science and Technology Innovation Co., Ltd, Nanchang Cables Co., Ltd, Shanghai Nanyang-Fujikura Cable Co., Ltd, Shanghai Laogang Shenling Electric Cable Co., Ltd, Shenzhen Liajiaxiang Science & Technology Co., Ltd, Tianjin Jinshan Electric Wire & Cable Ltd, and ShangHai Panda Wire & Cable Co., Ltd. The chief drafting staffs of this part. Ding Xiaoqing, He Shaoqing, Ai Weimin, He Wenjun, Chen Jinmei, Yin Binxia, Xu Qiao, Gu Youming, Huang Donglian, Zheng Guojun, Zhou Xiaorong, Xiao Jidong, Yan Yongchang, Lu Yanhong, and Wu Min. This part replaces the following historical edition. — JB/T 8734.4-1998. Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 4. Insulated wires for internal wiring of equipment 1 Scope This Part of JB/T 8734 specifies the operating characteristics, models, specifications, technical requirements and inspection of wires for internal wiring. This Part applies to copper core polyvinyl chloride insulated wires for internal wiring of electric appliance, instrument, electronic equipment and automation equipment of AC rated voltage U0/U up to and including 300/300V. 2 Normative references The articles contained in the following documents have become part of this document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document. GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11. Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12. Methods for general application - Thermal ageing methods GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 13. Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14. Methods for general application - Test at low temperature GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31. Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32. Methods specific to PVC compounds - Loss of mass test - Thermal stability test GB/T 5023.2-2008 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 2. Test methods GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions - Part 12. Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame GB/T 18380.22-2008 Tests on electric and optical fibre cables under fire conditions - Part 22. Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame JB/T 8734.1-2012 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V - Part 1. General requirements 3 Operational characteristics 3.1 Cable’s rated voltage U0/U is 300/300V. 3.2 Allowable long-term working temperature of AV-90, AVR-90 type wires shall not exceed 90°C. Allowable long-term working temperature of other types wires and cables shall not exceed 70°C. Note. When the operating environment of wires can prevent thermoplastic flow and allow reducing insulation resistance, for the polyvinyl chloride compound which can be used continuously at 90°C, its working temperature can be increased to 105°C, on the premise of shortening the total working hours. 4 Models Wires and cables’ models are shown in Table 1. 2 Structure size inspection 2.1 Structure inspection T, S T, S T, S T, S T, S T, S Normal eyesight inspection 2.2 Conductor - conduction test R R R R R R JB/T 8734.1-2012 5.5 23 Insulation thickness T, S T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.9 2.4 Sheath thickness - - - - T, S - GB/T 5023.2 2008 1.10 2.5 External diameter or appearance dimension T, S T, S T, S T, S T, S T, S GB/T 5023.2-2008 1.11 2.6 Ovality - - - - T, S - GB/T 5023.2-2008 1.11 Mechanical properties of the insulation 3.1 Tension test before aging T T T T T T GB/T 2951.11-2008 9.1 3.2 Tension test after aging T T T T T T GB/T 2951.12-2008 8.13.1 GB/T 2951.11-2008 9.1 3.3 Weightlessness test T T T T T T GB/T 2951.32-2008 8.1 4 Insulation thermal shrinkage test T T T T T T GB/T 2951.13-2008 Chapter Mechanical properties of the sheath 5.1 Tension test before aging - - - - T - GB/T 2951.11-2008 9.2 5.2 Tension test after aging - - - - T - GB/T 2951.12-2008 8.1.3.1 GB/T 2951.11-2008 9.2 5.3 Weightlessness test - - - - T - GB/T 2951-32-2008 8.2 6 High temperature pressure test 6.1 Insulation T T T T T T GB/T 2951.31-2008 8.1 6.2 Sheath - - - - T - GB/T 2951.31-2008 8.2 Low temperature flexibility and shock strength 7.1 Insulation low temperature winding test T T T T T T GB/T 2951.14-2008 8.1 7.2 Sheath low-temperature winding test - - - - T - GB/T 2951.14-2008 8.2 7.3 Sheath low-temperature Tension test - - - - T - GB/T 2951.14-2008 8.4 7.4 Finished wires and cables - low temperature shock test - - - - T - GB/T 2951.14-2008 8.5 8 Thermal shock test 8.1 Insulation T T T T T T GB/T 2951.31-2008 9.1 8.2 Sheath - - - - T - GB/T 2951.31-2008 9.2 Mechanical strength test of finished wires and cables 9.1 Insulated... ......

Similar standards: JB/T 8734.1-2016  JB/T 8734.2-2016  JB/T 8734.3-2016  
Similar PDFs (Auto-delivered in 9 seconds): JB/T 8734.4-2012  GB/T 9330.1-2008  GB/T 6995.5-2008