HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

HG/T 3009-1999 English PDF (HGT3009-1986)

HG/T 3009-1999_English: PDF (HG/T3009-1999)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
HG/T 3009-1999English80 Add to Cart 0--9 seconds. Auto-delivery Photographic film and film base - Determination of thickness by mechanical scanning   HG/T 3009-1999
HG/T 3009-1986EnglishRFQ ASK 3 days [Need to translate] (Chinese Industry Standard) Obsolete HG/T 3009-1986


BASIC DATA
Standard ID HG/T 3009-1999 (HG/T3009-1999)
Description (Translated English) Photographic film and film base - Determination of thickness by mechanical scanning
Sector / Industry Chemical Industry Industry Standard (Recommended)
Classification of Chinese Standard G80
Classification of International Standard 37.040.20; 37.060.20; 71.040.50
Word Count Estimation 4,477
Date of Issue 1999/6/16
Date of Implementation 2000/6/1
Older Standard (superseded by this standard) HG/T 3009-1986
Adopted Standard ISO 4593-1993, MOD
Drafting Organization China Lucky Film Company
Administrative Organization Ministry of Chemical Industry Standardization Technical focal point of photosensitive material
Summary This standard specifies the determination of photographic film, film base thickness by mechanical scanning method. This standard does not apply to film thickness measurement base pressure of lace.

BASIC DATA
Standard ID HG/T 3009-1986 (HG/T3009-1986)
Description (Translated English) (Chinese Industry Standard)
Sector / Industry Chemical Industry Industry Standard (Recommended)


HG/T 3009-1999 ICS 37.040.20; 37.060.20; 71.040.50 Record Number. 3763-1999 HG Chemical Industry Standard of the People’s Republic of China eqv ISO4593.1993 Replacing HG/T 3009-1986 Photographic film and film base - determination of thickness by mechanical scanning ISSUED ON. JUNE 16, 1999 IMPLEMENTED ON. JUNE 1, 2000 Issued by. State Oil and Chemical Industry Authority Table of Contents Foreword ... 3  ISO Foreword ... 4  1 Scope ... 5  2 Instruments ... 5  3 Test samples ... 6  4 Procedure ... 6  5 Precision ... 7  6 Test report ... 7  Foreword This standard is equivalent to international standards ISO4593.1993 “Plastics - Film and sheeting - Determination of thickness by mechanical scanning”. It is revised based on the chemical industry standard HG/T 3009-1986 "Film base thickness determination method". Compared with HG/T 3009, the main technical differences are as follows. The format and technical content are written based on ISO4593. Delete the 2 chapters - Definition and Principles. Amend the content to chapter Application Scope; Add the sampling requirements of the photosensitive material. Since the date of implementation, this standard shall replaces HG/T 3009-1986. This standard was proposed by the Technical Supervision Division of former Ministry of Chemical Industry. This standard shall be under the jurisdiction of the Standardization Technical Focal Division of Photosensitive Material of Ministry of Chemical Industry. The drafting organizations of this standard. China Lucky Film Corporation, and Wuxi Aermei Film & Chemicals Corporation. The main drafters of this standard. Wu Xiankai, and Xie Qingyao. This standard was first-time released in September 1986 as a national standard. In 1997, it was adjusted to be the recommended chemical industry standard; and the serial number was re-numbered. Photographic film and film base - determination of thickness by mechanical scanning 1 Scope    This standard specifies the determination of photographic film, and film base thickness by using mechanical scanning method. This standard does not apply to the determination of the thickness of the embossed film base1. 2 Instruments  2.1 Thickness measuring device It shall meet the following accuracy. Measuring range is below 100 µm, including 100 µm. The accuracy shall meet 1 µm; Measuring range is between 100 µm and 250 µm, including 250 µm. The accuracy shall meet 2 µm; Measuring range is above 250 µm. The accuracy shall meet 3 µm. NOTE. If above accuracy is not sufficient, and a higher accuracy is required, the suitable measuring instrument or method may be selected. ISO4591.1992 “Plastics - Film and sheeting - Determination of sample’s average thickness, roll’s average thickness and surface area of unit-weight (gravimetric-method thickness) by using gravimetric-method” describes the determination of gravimetric thickness. The measuring surface of the device shall be consisted of a lower plane AND another plane or a radiused upper plane. All surfaces shall be polished. 2.1.1 For the plane / surface, the diameter of each surface shall be between 2.5 – 10 mm. The parallelism shall be within 5 µm. The lower surface shall be adjustable. The force applied to the measuring face shall be between 0.5 N – 1.0 N. 1 The scope of this standard has been amended so as to apply to photosensitive material. e) The number of samples measured; f) The arithmetic mean of the individual measurements (accurate to 1 µm or 0.001 µm) shall be the average mechanically measured thickness of the test samples. If necessary, it shall also report the individual measured values; g) Report the number and frequency of measurement. If necessary, it shall also report the standard deviation. ......

Similar standards: HG/T 5311-2018  HG/T 4127-2017  HG/T 5143-2017  
Similar PDFs (Auto-delivered in 9 seconds): HG/T 3009-1999  GB 38508-2020  GB/T 40260-2021