HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (14 Sep 2024)

GB/T 9330-2020 English PDF

GB/T 9330-2020 (GB/T9330-2020, GBT 9330-2020, GBT9330-2020)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 9330-2020English559 Add to Cart 6 days [Need to translate] Plastic insulated control cables Valid GB/T 9330-2020
Standards related to: GB/T 9330-2020

BASIC DATA
Standard ID GB/T 9330-2020 (GB/T9330-2020)
Description (Translated English) Plastic insulated control cables
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 30,361
Date of Issue 2020-03-31
Date of Implementation 2020-10-01
Drafting Organization Shanghai State Cable Testing Center Co., Ltd., Baosheng Technology Innovation Co., Ltd., Yangzhou Shuguang Cable Co., Ltd., Jiangsu Zhongtian Technology Co., Ltd., Jiangsu Hengtong Cable Technology Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Qingdao Hancable Co., Ltd., Far East Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Anhui Pacific Cable Co., Ltd., Jinbei Electric Co., Ltd., Guangzhou Nanyang Cable Co., Ltd., Long-distance Cable Co., Ltd., Shanghai Shenghua Cable (Group) Co., Ltd., Guangzhou Cable Factory Co., Ltd., Jiangsu Yongding Co., Ltd., Kunming Cable Group Co., Ltd., Hainan Weite Electric Group Co., Ltd., Shenyang Aike Cable Technology Co., Ltd.
Administrative Organization National Standardization Technical Committee of Wire and Cable (SAC/TC 213)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

GB/T 9330-2020 Plastic insulated control cables ICS 29.060.20 K13 National Standards of People's Republic of China Replace GB/T 9330.1-2008, GB/T 9330.2-2008, GB/T 9330.3-2008 Plastic insulated control cable 2020-03-31 released 2020-10-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee Table of contents Preface Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Product code and representation 2 5 Cable name, model and specification 3 6 Finished cable marking and cable insulation core identification 5 7 Technical requirements and test methods 6 8 Finished cable 16 9 Delivery length 18 10 Inspection rules 18 11 Use characteristics 20 12 Packaging 20 Appendix A (Normative Appendix) Calculation method of assumed value 22 Preface This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 9330.1-2008 "Plastic insulated control cables Part 1.General regulations", GB/T 9330.2-2008 "Plastic insulated control cables Part 2.PVC insulated and sheathed control cables" and GB/T 9330.3-2008 "Plastic insulation control Cable Part 3.XLPE insulated control cable". This standard is based on GB/T 9330.1-2008 and integrates the parts of GB/T 9330.2-2008 and GB/T 9330.3-2008 Compared with GB/T 9330.1-2008, the main technical changes are as follows. ---Added copper/plastic composite tape (foil) shielding (see 4.1.3); --- Modify "Conductor of fixed laying cable" to "Conductor of hard structure cable" and "Conductor of mobile laying cable" to "Soft structure electrical The conductor of the cable" (see 7.1.2, 6.1.2 of the.2008 edition); --- Increased the shrinkage test and water absorption test of cross-linked polyethylene insulation (see Table 5); ---Increases the thickness requirements of the thinnest part of the metal (composite) belt metal layer, the requirements for the coverage rate of the metal (composite) belt shielding and the wire braiding Evaluation requirements for the diameter of woven shielding monofilament (see 7.4); ---Added the evaluation index for the thickness of the squeezed and wrapped inner lining and the test method for the average thickness of the wrapped inner lining (see 7.5.3); ---Added the assessment requirements for the thickness of the armored steel tape and the diameter of the armored steel wire and the test method for the size of the armor layer (see 7.6.2); ---Added sheath spark test requirements (see 7.7.2); ---Increase the mechanical and physical performance requirements of insulation (see Table 5); --- Delete the ST3 sheath (see Table 7 of the.2008 edition); ---The mechanical and physical performance requirements of the sheath have been increased (see Table 12 and Table 13); ---Added the requirements for the number of test and measurement cores (see Chapter 8); ---Added the halogen-free performance requirements of cable non-metallic materials (see Table 15); ---Inspection requirements have been added (see Table 19); ---The calculation method of the upper limit of cable outer diameter has been added (see A.2.7). This standard was proposed by China Electrical Equipment Industry Association. This standard is under the jurisdiction of the National Wire and Cable Standardization Technical Committee (SAC/TC213). Drafting organizations of this standard. Shanghai National Cable Testing Center Co., Ltd., Baosheng Technology Innovation Co., Ltd., Yangzhou Shuguang Cable Co., Ltd. Co., Ltd., Jiangsu Zhongtian Technology Co., Ltd., Jiangsu Hengtong Cable Technology Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Qingdao Han Cable Co., Ltd., Far East Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Anhui Pacific Cable Co., Ltd., Jinbei Electric Co., Ltd., Guangzhou Nanyang Cable Co., Ltd., Long-distance Cable Co., Ltd., Shanghai Shenghua Cable (Group) Co., Ltd., Guangzhou Electric Cable Factory Co., Ltd., Jiangsu Yongding Co., Ltd., Kunming Cable Group Co., Ltd., Hainan Weite Electric Group Co., Ltd., Shenyang Aike Cable Technology Co., Ltd. The main drafters of this standard. Yang Lizhi, Fang Quansheng, Liang Guohua, Ge Yongxin, Bian Fengxian, Li Bin, Qu Guoan, Wang Chuanbin, Liu Jun, Wang Yonghai, Yang Wenfeng, Wang Zhihui, Zhang Qianping, Li Xiaoqiu, Wang Xun, Zhao Peijie, Xi Youjian, Li Ju, Su Yinyu, Guo Rongrong, Ma Zhan, He Jieli, Du Qing. The previous versions of the standard replaced by this standard are as follows. ---GB/T 9330.1-1988, GB/T 9330.1-2008; ---GB/T 9330.2-1988, GB/T 9330.2-2008; ---GB/T 9330.3-2008. Plastic insulated control cable 1 Scope This standard specifies that the rated AC voltage U0/U is 450/750V extruded polyvinyl chloride and cross-linked polyethylene insulation, polyvinyl chloride, polyethylene Product code and representation method, cable name and model specification, finished cable mark and insulated core of olefin and halogen-free polyolefin sheathed control cable Identification, technical requirements, test methods and inspection rules, use characteristics and packaging, etc. This standard is applicable to fixed installations in occasions where the AC rated voltage U0/U is 450/750V and below, such as control, monitoring circuits and protection circuits. Set the control cable used. 2 Normative references The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 2900.10 Electrical terminology cable GB/T 2951.11-2008 General test methods for insulation and sheath materials of electric and optical cables-Part 11.General test methods Method---thickness and external dimension measurement---mechanical performance test GB/T 2951.12-2008 General test methods for insulation and sheath materials of electric and optical cables-Part 12.General test methods Method --- Thermal aging test method GB/T 2951.13-2008 General test methods for insulation and sheath materials of electric and optical cables-Part 13.General test methods Method---Density determination method---Water absorption test---Shrinkage test GB/T 2951.14-2008 General test methods for insulation and sheath materials of electric and optical cables-Part 14.General test methods Method --- Low Temperature Test GB/T 2951.21-2008 General test methods for insulating and sheathing materials of electric and optical cables Part 21.Elastomer mixture special Test method used---ozone resistance test---heat extension test---mineral oil immersion test GB/T 2951.31-2008 General test methods for insulating and sheathing materials of electric and optical cables-Part 31.Polyvinyl chloride mixture Special test method---High temperature pressure test---Crack resistance test GB/T 2951.32-2008 General test methods for insulating and sheathing materials of electric and optical cables-Part 32.Polyvinyl chloride mixture Special test method---weight loss test---thermal stability test GB/T 2951.41-2008 General test methods for insulating and sheathing materials of electric and optical cables-Part 41.Polyethylene and polypropylene Special test method for mixture---Environmental stress cracking resistance test---Melt index measurement method---Measurement of carbon in polyethylene by direct combustion method Black and (or) mineral filler content --- thermogravimetric analysis (TGA) measurement of carbon black content --- microscope method to evaluate carbon black content in polyethylene Divergence GB/T 3048.4-2007 Electric wire and cable electrical performance test method Part 4.Conductor DC resistance test GB/T 3048.5-2007 Electric wire and cable electrical performance test method Part 5.Insulation resistance test GB/T 3048.8-2007 Test methods for electrical properties of wires and cables Part 8.AC voltage test GB/T 3048.9-2007 Electric wire and cable electrical performance test method Part 9.Insulated core spark test GB/T 3048.10-2007 Test methods for electrical properties of wires and cables Part 10.Extrusion sheath spark test ...