HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (19 Apr 2025)

GB/T 8570.6-2010 English PDF (GB/T 8570.6-1988: Older version)

Search result: GB/T 8570.6-2010 (GB/T 8570.6-1988 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 8570.6-2010English139 Add to Cart 3 days [Need to translate] Determination of liquefied anhydrous ammonia -- Part 6: Oil content -- Gravimetric and infra-red methods Valid GB/T 8570.6-2010
GB/T 8570.6-1988English199 Add to Cart 2 days [Need to translate] Liquefied anhydrous ammonia--Determination of oil content--Gravimetric and infra-red methods Obsolete GB/T 8570.6-1988


BASIC DATA
Standard ID GB/T 8570.6-2010 (GB/T8570.6-2010)
Description (Translated English) Determination of liquefied anhydrous ammonia. Part 6: Oil content. Gravimetric and infra-red methods
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G10
Classification of International Standard 71.040.40
Word Count Estimation 6,635
Date of Issue 2010-09-26
Date of Implementation 2011-03-01
Older Standard (superseded by this standard) GB/T 8570.6-1988
Quoted Standard GB/T 8570.1; GB/T 8570.3-2010; GB/T 8570.4; HG/T 2843
Adopted Standard ISO 7106-1985, MOD
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies two methods for determining anhydrous liquid nitrogen (ammonia) African volatile oil content-Gravimetric method and infrared absorption spectroscopy. Warning: The use of this standard personnel practices should be implemented in a regular room to work, the standard does not indicate that all possible security problems, the user has the responsibility to take appropriate safety and health practices to ensure compliance with conditions of wells national law liquid anhydrous ammonia highly toxic to the skin, mucous membranes and eyes corrosive, exposure can cause severe burns, the operation should be adequate protection. When the oil is below the determination of the weight of law 5mg/kg, the test results with " less than 5mg/kg quoted, or using infrared absorption spectroscopy.


GB/T 8570.6-2010 Determination of liquefied anhydrous ammonia .Part 6. Oil content.Gravimetric and infra-red methods ICS 71.040.40 G10 National Standards of People's Republic of China Replacing GB/T 8570.6-1988 Determination of liquid anhydrous ammonia Part 6. Oil content Gravimetric and infrared absorption spectroscopy Determination ofliquefiedanhydrousammonia- Part 6. Oilcontent-Gravimetricandinfra-redmethods (ISO 7106. 1985 Liquefiedanhydrousammoniaforindustrialuse- infra-redspectrometricmethods, MOD) 2010-09-26 release.2011-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Preface GB/T 8570 "Determination of liquid anhydrous ammonia method" is divided into seven parts. - Part 1. Adoption of laboratory samples; - Part 2. Ammonia content; - Part 3. Residue content weight method; - Part 4. Residual content volumetric method; - Part 5. Moisture Fisher Fischer; - Part 6. Oil content gravimetric and infrared absorption spectroscopy; - Part 7. Iron content - phenanthroline spectrophotometric method. This part is Part 6 of GB/T 8570. This part of the replacement GB/T 8570.6-1988 "liquid anhydrous ammonia content determination of gravimetric and infrared spectroscopy." This part of the revision using ISO 7106. 1985 "industrial liquid anhydrous ammonia content of the determination of weight and infrared spectroscopy." The main differences between this part and ISO 7106. 1985 are. ISO 7106 taken sample.200 mL, this part is based on liquid anhydrous ammonia Oil content ≤ 5mg/kg requirements, modified to 400mL; used sulfuric acid absorption solution concentration corresponding to 1 times, 20%. The main differences between this edition and the previous edition are. Preparation and calibration of reagent solutions, standard titration solutions, etc. Execution of HG/T 2843 standards; --- increase the contents of the security warning; - standardize the standard format according to the new requirements. This section is proposed by the China Petroleum and Chemical Industry Association. This section is under the jurisdiction of the National Technical Committee on Standardization of Fertilizers and Soil Conditioners (SAC/TC105). This part of the drafting unit. the National Fertilizer Quality Supervision and Inspection Center (Shanghai), the Eastern Airlines Co., Ltd. Security Department. The main drafters of this part. Ji Min, Wu Juan, Feng Zhuo, Chen Jie. This part was first published in 1988. Determination of liquid anhydrous ammonia Part 6. Oil content Gravimetric and infrared absorption spectroscopy WARNING - Personnel using this standard should have practical experience in formal laboratory work. This standard does not indicate all possible security questions question. It is the responsibility of the user to take appropriate safety and health measures and to ensure compliance with the conditions of the relevant national laws. Liquid anhydrous ammonia high Toxic to the skin, mucous membranes and eyes are corrosive, contact can cause severe burns. Operation should be properly protected. 1 Scope GB/T 8570 of this part of the liquid anhydrous ammonia (liquid ammonia) in about 105 ℃ non-volatile oil content of the two methods of determination. weight Method and infrared absorption spectroscopy. When the oil content measured by gravimetric method is less than 5mg/kg, the test result is reported as "less than 5mg/kg" or infrared absorption Spectrophotometric method. 2 normative reference documents The terms of this document are the terms of this part by reference to this part of GB/T 8570. Any reference to the date of the text , All subsequent amendments (excluding corrigenda) or revisions do not apply to this part, however, encouragement under this section The parties to the agreement study whether the latest version of these documents can be used. For undated references, the latest edition of this document applies section. GB/T 8570.1 Methods for the determination of liquid anhydrous ammonia - Part 1. Adoption of laboratory samples GB/T 8570.3-2010 Methods for the determination of liquid anhydrous ammonia - Part 3. Residue content gravimetric method Methods for the determination of anhydrous ammonia - Part 4. Residue content volumetric method GB/T HG/T 2843 chemical analysis of chemical fertilizers commonly used standard titration solution, standard solution, reagent solution and indicator solution 3 principle After evaporation of the liquid ammonia sample at room temperature, the oil in the residue was extracted with carbon tetrachloride. After heating to remove carbon tetrachloride, weighed and left ; Or at a fixed wavelength of about 3.42 m (corresponding to the strongest absorption band of asymmetric vibrations of the CH group), the organic matter Absorbance. 4 reagents and materials The following parts of the reagents and solutions are toxic or corrosive, the operator should be careful to prevent inhalation of its vapor, the skin and eye contact is strictly prohibited, Such as splashing on the skin should be immediately washed with water or suitable way to deal with, if not suited to immediate medical treatment. The reagents, solutions and water used in this part shall comply with the requirements of HG/T 2843 when not specified and formulated. 4.1 carbon tetrachloride. for infrared absorption spectrometry determination, the analysis wavelength of 3.42μm in the vicinity, should not contain the wavelength of infrared light Absorbable impurities; 4.2 sulfuric acid solution, the mass fraction of about 20%; 4.3 hydrochloric acid solution, the mass fraction of about 10%; 4.4 paraffin oil standard solution. 0.5mg/mL carbon tetrachloride solution. Weigh 0.050g spectrum of pure paraffin oil (commonly used n-hexadecane), said quasi-0.0002g, placed in 100mL beaker, add carbon tetrachloride To about 50mL, to be dissolved, all transferred into the 100mL volumetric flask, diluted with the same carbon tetrachloride to the scale, shake; ......

Similar standards: GB/T 3049   GB/T 6284   GB/T 3050   GB/T 8570.4   GB/T 8570.5   GB/T 8570.3