Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Nov 28, 2020)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB/T 8372-2017

Chinese Standard: 'GB/T 8372-2017'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB/T 8372-2017English150 Add to Cart 0--10 minutes. Auto immediate delivery. Toothpaste Valid GB/T 8372-2017
GB/T 8372-2017Chinese20 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]  

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID GB/T 8372-2017 (GB/T8372-2017)
Description (Translated English) Toothpaste
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y43
Classification of International Standard 71.100.40
Word Count Estimation 16,128
Date of Issue 2017-11-01
Date of Implementation 2018-05-01
Older Standard (superseded by this standard) GB 8372-2008
Drafting Organization Chongqing Dengkang Oral Care Products Co., Ltd., Shanghai, Japan and the United States and Japan on the Limited, the national light industrial toothpaste wax product quality supervision and inspection center, Yunnan Baiyao Group Co., Ltd.
Administrative Organization National Oral Care Products Standardization Technical Committee (SAC/TC 492)
Regulation (derived from) National Standard Announcement 2017 No. 29
Proposing organization China National Light Industry Council
Issuing agency(ies) People's Republic of China General Administration of Quality Supervision, Inspection and Quarantine, China National Standardization Administration

GB/T 8372-2017
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.100.40
Y 43
Replacing GB 8372-2008
Toothpaste
牙膏
ISSUED ON: NOVEMBER 01, 2017
IMPLEMENTED ON: MAY 01, 2018
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the PRC;
Standardization Administration of the PRC.
Table of Contents
Foreword ... 3 
1 Scope ... 5 
2 Normative references ... 5 
3 Terms and definitions ... 6 
4 Requirements ... 6 
5 Test methods ... 8 
6 Inspection rules ... 18 
7 Marking ... 20 
8 Transportation and storage ... 20 
Appendix A (Normative) Determination of lead content by direct injection of
graphite furnace ... 21 
Appendix B (Informative) Gas chromatogram of fluoride ion standard solution
... 23 
Toothpaste
1 Scope
This Standard specifies the terms and definitions, requirements, test methods,
inspection rules, marking, transportation and storage of toothpaste.
This Standard applies to toothpaste for cleansing and care of the mouth.
2 Normative references
The following documents are indispensable for the application of this document.
For the dated references, only the editions with the dates indicated are
applicable to this document. For the undated references, the latest edition
(including all the amendments) are applicable to this document.
GB/T 191 Packaging - Pictorial Marking for Handling of Goods
GB/T 601 Chemical Reagent - Preparations of Standard Volumetric
Solutions
GB/T 602 Chemical Reagent - Preparations of Standard Solutions for
Impurity
GB/T 603 Chemical Reagent - Preparations of Reagent Solutions for Use in
Test Methods
GB/T 6682 Water for analytical laboratory use - Specification and test
methods
GB 7917.2 Standard methods of hygienic test for cosmetics - Arsenic
GB 22115 General requirements on raw materials of toothpastes
GB 29337 General labeling for oral care and cleansing products
JJF 1070 Rules of Metrological Testing for Net Quantity of Products in
Prepackages with Fixed Content
Measures for the Metrological Supervision and Administration of Products in
Prepackages with Fixed Content (No. 75 Decree [2005] by the General
Administration of Quality Supervision, Inspection and Quarantine)
Safety and Technical Standards for Cosmetics (China Food and Drug
4.6 Packaging appearance requirements
4.6.1 Hose or other packaging
The cap and the hose mouth are tightly matched. There shall be no damage to
the hose body and no paste leakage.
4.6.2 Box (for toothpaste packaged in small box)
The box shall be free from damage.
5 Test methods
The reagents and water used in this Standard, unless otherwise specified, are
analytically pure reagents and water in accordance with GB/T 6682.
In this Standard, standard solutions for titrimetric analysis, standard solutions
for impurity determination, and preparations and products used in test methods,
unless otherwise specified, are prepared according to the provisions of GB/T
601, GB/T 602, and GB/T 603.
For indicators whose final test result is calculated by the weighing method, use
the sampling method of first squeezing 20 mm of paste out and discarding and
then squeezing again and weighing.
5.1 Microbiological indicators
It shall be in accordance with Clause 5 Microbiological inspection methods of
“Safety and Technical Standards for Cosmetics”.
5.2 Lead (Pb) content
5.2.1 General
This method is an arbitration inspection method. Non-arbitration inspection may
be carried out in accordance with the provisions of Appendix A.
5.2.2 Toothpaste with calcium carbonate or calcium hydrogen phosphate
as friction agent
5.2.2.1 Reagents
5.2.2.1.1 Nitric acid.
5.2.2.1.2 Nitric acid solution: 5 mol/L.
5.2.2.1.3 Nitric acid solution: 0.2 mol/L.
shake; HEAT on small fire until hydrogen peroxide completely decomposes. If
reddish brown nitrogen dioxide fumes are generated, immediately add 2 mL of
10% ammonium sulfamate solution and heat until the solution boils slightly;
quickly add water to 50 mL, to let it cool rapidly; ADD 3 mL of aqueous ammonia;
COOL to room temperature and then transfer the solution to a 100 mL beaker;
USE 10 mL of water to wash the conical flask twice. USE aqueous ammonia
and 1% ammonium hydroxide solution to adjust the pH to 1.1~1.2. At this point,
a small amount of turbidity will appear in the solution. It is filtered into a 125 mL
separatory funnel. USE 5 mL of water to wash the beaker and funnel. ADD 1
mL of 2% ammonium tetrahydropyrrole dithiocarbamate solution to the solution
and shake well; PLACE it for about 3 min; ADD 10 mL of trichloromethane and
shake for 2 min. After layering, transfer the trichloromethane layer to another
separatory funnel; then use 10 mL of trichloromethane to repeatedly extract;
COMBINE the extracts. ADD 10.0 mL of Hg2+ solution and shake for 2 min; after
layering, take the upper aqueous phase for flame atomic absorption
determination. At the same time, use 0.01 mol/L nitric acid solution as blank;
determine the absorbance of lead standard series 1 μg/mL, 3 μg/mL, 5 μg/mL.
USE the lead concentration as the abscissa and the lead absorbance as the
ordinate, to draw a standard curve.
5.2.3 Toothpaste with silica or aluminum hydroxide as friction agent
5.2.3.1 Reagents
Sulfuric acid.
Other reagents are the same as 5.2.2.1.
5.2.3.2 Apparatus
Same as 5.2.2.2.
5.2.3.3 Preparation and determination of sample
5.2.3.3.1 Silica toothpaste
Randomly take 1 sample toothpaste, from which weigh 2 g of toothpaste,
accurate to 0.01 g; PLACE it in a 250 mL conical flask; ADD 5 mL of water and
5 mL of nitric acid; USE a small fire to heat, until the paste dissolves. Slightly
cool, add 1.5 mL of hydrogen peroxide solution and shake; USE a small fire to
heat, until reddish brown nitrogen dioxide gas generates. Immediately add 2 mL
of 10% ammonium sulfamate solution; REMOVE when slightly hot; ADD 20 mL
of water; COOL to room temperature; USE two layers of filter paper to suction-
filter. USE 15 mL of water to wash the conical flask and the inner wall of Buchner
funnel and the precipitate several times; TRANSFER the suction-filtrate to a
100 mL beaker; USE 10 mL of water to wash the filter bottle twice; adjust the
5.5.2 Determination procedure
Randomly take 1 sample toothpaste, from which weigh 5 g of toothpaste,
accurate to 0.01 g. PLACE it in a 50 mL beaker; ADD 20 mL of pre-boiled and
cooled distilled water and stir well; at 20 ° C, use a pH meter to measure; within
10 min, read the indicated value.
5.5.3 Result representation
The absolute difference of the parallel measured values is not more than 0.1pH
unit. The arithmetic mean is taken as the measurement result.
5.6 Stability
5.6.1 Apparatus
5.6.1.1 Refrigerator: Accuracy is ±1 °C.
5.6.1.2 Electrothermal constant-temperature incubator: Accuracy is ±1 °C.
5.6.2 Determination procedure
TAKE 2 sample toothpaste. 1 sample is stored at room temperature. The other
sample is placed in a refrigerator at -8 °C±1 °C. After 8 h, it is taken out; then
placed in a constant-temperature incubator at 45 °C±1 °C and taken out after 8
h. Restore to room temperature; OPEN the lid; the paste shall not overflow the
hose mouth. INVERT the toothpaste hose. Within 10 s, no liquid shall drip out
from the hose mouth. After the paste is squeezed out, it is compared with the
sample stored at room temperature. The fragrance and color shall be normal.
5.7 Hard particles
5.7.1 Apparatus
5.7.1.1 Hard particle tester: 1.
5.7.1.2 Slide: 75 mm×25 mm.
5.7.2 Reagents
Nitric acid: 1+1.
5.7.3 Determination procedure
TAKE 1 sample toothpaste, from which weigh 5 g of toothpaste onto a scratch-
free slide; PUT the slide into the fixed slot of the tester; PRESS a friction copper
block on; START the switch, to make the copper block reciprocally rub 100
times. After that, stop the friction; TAKE the slide out; USE water or hot nitric
respectively. ADD 5 mL of citrate buffer respectively; USE deionized water to
dilute to the mark; then transfer to 50 mL plastic beaker one by one. Under
magnetic stirring, measure the potential value E. RECORD and make an E-log
c (c is concentration) standard curve.
5.8.5 Determination of soluble fluorine
Accurately pipette 2.0 mL of the supernatant prepared in 5.8.3 and transfer to
a 5 mL microcentrifuge tube. ADD 0.7 mL of 4 mol/L hydrochloric acid; COVER
the centrifuge tube; PUT in a 50 °C water bath for 10 min; TRANSFER to a 50
mL plastic volumetric flask; ADD 0.7 mL of 4 mol/L sodium hydroxide to
neutralize and add 5 mL of citrate buffer. USE deionized water to dilute to the
mark; TRANSFER to a 50 mL plastic beaker. Under magnetic stirring, measure
the potential value. From the standard curve, the corresponding fluorine content
is obtained, to calculate the soluble fluorine content.
5.8.6 Determination of free fluorine
Accurately pipette 2.0 mL of the supernatant prepared in 5.8.3 into a 50 mL
plastic volumetric flask. ADD 5 mL of citrate buffer; USE deionized water to
dilute to the mark; TRANSFER to a 50 mL plastic beaker. Under magnetic
stirring, measure the potential value. From the standard curve, the
corresponding fluorine content is obtained, to calculate the free fluorine content.
If the free fluorine content in the sample is too high, according to the actual
situation, the sampling quantity may be appropriately diluted or reduced.
5.8.7 Calculation formula
According to formula (1), calculate the soluble fluorine or free fluorine content
(X) in the sample:
Where:
X - Soluble fluorine or free fluorine content, in milligrams per kilogram (mg/kg);
c - Fluorine content in the test solution, in milligrams per kilogram (mg/kg);
m - Sample mass, in grams (g).
Finally, the above calculation result unit (mg/kg) is converted into a percentage
concentration and is accurate to two digits after the decimal point.
5.8.8 Allowable difference
The allowable difference of the results of the two parallel determinations is ±5%.
5.9.4.1 Temperature programming: Initial temperature is 60 °C. Initial time is
1.8 min. Heating rate is 40 °C/min. Final temperature is 160 °C, hold for 3 min.
5.9.4.2 Inlet temperature: 200 °C.
5.9.4.3 Detector (FID) temperature: 300 °C.
5.9.4.4 Carrier gas: Nitrogen, 42.3 kPa.
5.9.4.5 Split ratio: 1+13.
5.9.4.6 Septum purge: 2 mL/min.
5.9.4.7 Make-up gas: Nitrogen, 25 mL/min.
5.9.5 Preparation of fluoride ion standard solution and internal standard
solution
5.9.5.1 Preparation of fluoride ion standard solution
Prepare according to 5.8.2.4.
5.9.5.2 Preparation of internal standard solution
WEIGH about 0.5 g of n-pentane in a 100 mL glass volumetric flask; USE
toluene to dilute to the mark and shake well. This internal standard stock
solution is stored in the refrigerator and is valid for 1 month.
PIPETTE 5.0 mL of the internal standard stock solution into a 250 mL glass
volumetric flask; USE toluene to dilute to the mark and shake well. This internal
standard solution must be re-prepared each time.
During the same analysis, all standard solutions and sample solutions must be
prepared with the same internal standard solution.
5.9.6 Preparation of standard solution and sample solution
5.9.6.1 Preparation of standard solution
PIPETTE 1.0 mL and 5.0 mL of fluoride ion standard solution into 2 40 mL
plastic bottles with caps; ADD 10% sodium chloride solution to make the total
volume 10 mL; obtain standard solution A and solution B. The fluoride ion
masses are 0.1 mg and 0.5 mg, respectively.
5.9.6.2 Preparation of sample solution
WEIGH approximately 0.2 g of sample (accurate to 0.0001 g) into a 40 mL
plastic bottle with cap. PUT 3 glass beads in; ADD 10.0 mL of 10% sodium
According to formula (3), calculate the total fluorine content (Z) in the sample:
Where:
Z - The total fluorine content in the sample. The result is accurate to two digits
after the decimal point, %;
A3 - The peak area of the fluoride in the sample solution;
A4 - The peak area of n-pentane in the sample solution;
m - Sample mass, in milligrams (mg).
The detection limit of this method is 0.2 mg/kg. The lower limit of quantitation is
1 mg/kg.
5.10 Determination of net quantity
It shall be carried out according to JJF 1070.
6 Inspection rules
6.1 Inspection classification
6.1.1 Type inspection
Toothpaste type inspection includes all items in the standard. During normal
production, it shall not be less than one time per quarter. In one of the following
cases, type inspection shall also be carried out:
a) When there is a significant change in one of raw materials, processes, and
formulations and the product performance may be affected;
b) When the production resumes after the product is discontinued for a long
time;
c) When the exit-factory inspection result of the product is significantly
different from the previous type inspection;
d) When the national quality supervision agency proposes a requirement for
type inspection.
6.1.2 Exit-factory inspection
7 Marking
7.1 The sales packaging and maximum surface area calculation method of the
product shall be carried out in accordance with the provisions of GB 29337.
7.2 Large packaging shall have the following marks:
a) Product name;
b) Producer’s name and plant site: The producer’s name and address shall
be the name and address of the producer who is legally registered and
can bear the responsibility for product quality;
c) Packing quantity, gross weight;
d) Production date or restricted use date and production lot number;
e) Packaging case volume [length (mm)×width (mm)×height (mm)];
f) Pictorial marking for handling of package: The enterprise shall, based on
the actual requirements of the product, according to the provisions of GB/T
191, indicate pictorial marking for handling of large package.
8 Transportation and storage
8.1 Transportation
It must be lightly loaded and unloaded and stacked according to box arrows. It
shall avoid severe shake, impact, and sun and rain.
8.2 Storage
It shall be stored in a ventilated and dry warehouse. It shall not be close to the
water source and h......
Related standard:   GB/T 38741-2020  GB/T 38789-2020
Related PDF sample:   GB/T 9104-2008
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2020