Standard ID | GB/T 6730.55-2019 (GB/T6730.55-2019) | Description (Translated English) | Iron ores -- Determination of tin content -- Flame atomic absorption spectrometric method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | D31 | Classification of International Standard | 73.060.10 | Word Count Estimation | 10,160 | Date of Issue | 2019-03-25 | Date of Implementation | 2020-02-01 | Drafting Organization | Baoshan Iron and Steel Co., Ltd., Guangxi Liuzhou Iron and Steel Group Co., Ltd., Shanxi Jianlong Industrial Co., Ltd., Metallurgical Industry Standard Information Research Institute | Administrative Organization | National Iron Ore and Direct Reduced Iron Standardization Technical Committee (SAC/TC 317) | Proposing organization | China Iron and Steel Association | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration | Standard ID | GB/T 6730.55-2004 (GB/T6730.55-2004) | Description (Translated English) | Iron ores. Determination of tin content. Flame atomic absorption spectrometric method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | D31 | Classification of International Standard | 73.060.10 | Word Count Estimation | 10,133 | Date of Issue | 2004-03-24 | Date of Implementation | 2004-09-01 | Quoted Standard | GB/T 6682; GB/T 6730.1; GB/T 10322.1; GB/T 12806; GB/T 12808 | Adopted Standard | ISO 11534-1998; MOD | Drafting Organization | Baoshan Iron & Steel Co., Ltd. | Administrative Organization | Metallurgical Industry Information Standards Institute | Regulation (derived from) | Announcement of Newly Approved National Standards No. 4, 2004 (No. 66 overall) | Proposing organization | China Iron and Steel Industry Association | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China, China National Standardization Administration Committee | Summary | This standard specifies: Determination of iron content Shizhong Xi flame atomic absorption spectrometry. This standard applies to: natural iron ore, iron ore and lump ore, including sintered product of tin content determined. Measuring range (mass fraction) |
GB/T 6730.55-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 73.060.10
D 31
Replacing GB/T 6730.55-2019
Iron ores - Determination of tin content -
Flame atomic absorption spectrometric method
(ISO 11534:2006, Iron ores – determination of tin -
Flame atomic absorption spectrometric method, MOD)
ISSUED ON: MARCH 25, 2019
IMPLEMENTED ON: FEBRUARY 1, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Principle ... 6
4 Reagents ... 6
5 Apparatus ... 7
6 Sampling and samples ... 8
7 Procedure ... 8
8 Expression of results ... 10
9 Test report ... 13
Annex A (Normative) Flowsheet of the procedure for the acceptance of
analytical values for test samples ... 14
Annex B (Informative) Derivation of repeatability and permissible tolerance
equations ... 16
Foreword
GB/T 6730, Iron ores, comprises dozens of parts.
This Part is the 55th part of GB/T 6730.
This Part was drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 6730.55-2004, Iron ores – Determination of tin content –
Flame atomic absorption spectrometric method. The significant technical changes with
respect to GB/T 6730.55-2004, in addition to some editorial changes, are as follows:
-- it adds in apparatus high temperature furnace suitable for heating to 1 000°C ~ 1
020°C (see 5.4);
-- it changes the requirements for sample amount, accurate to 0.000 2 g (see 7.2;
7.2 of edition 2004);
-- it changes the precision regression equation (see 8.2.1; 8.2.1 of edition 2004);
-- it changes the trueness check equation (see 8.2.4; 8.2.4 of edition 2004).
This Part was redrafted by modifying and adopting ISO 11534:2006, Iron ores –
Determination of tin – Flame atomic absorption spectrometric method.
The technical differences between this Part and ISO 11534:2006, and the reasons, are
as follows:
-- with respect to normative references, some adjustments are made in this Part
resulting in some technical differences, in order to adapt to the technical conditions
in China. The adjustments are intensively reflected in “Normative references” of
Clause 2. This Part:
adds the references including GB/T 6379.1, GB/T 6379.2, GB/T 7728, GB/T
8170, GB/T 12807, GB/T 12808 (see Clause 5, 8.2.1, 8.2.5);
deletes ISO 648;
uses GB/T 6682 modifying and adopting the international standard to
replace ISO 3696 (see Clause 4);
uses GB/T 6730.1 modifying and adopting the international standard to
replace ISO 7764 (see 6.2);
uses GB/T 10322.1 equivalently adopting the international standard to
replace ISO 3082 (see 6.1);
uses GB/T 12806 non-equivalently adopting the international standard to
replace 1042 (see Clause 5);
-- it adjusts the sequence and numbers of the clauses in the “Reagents”
Iron ores – Determination of tin content – Flame
atomic absorption spectrometric method
Warning – The operators using this Part shall have practical experiences
in the work in a normal laboratory. This Part does not purport to address
all of the safety problems associated with its use. It is the responsibility
of the user of this Part to establish appropriate health and safety practices
and determine the applicability of regulatory limitations prior to use.
1 Scope
This Part of GB/T 6730 specifies the flame atomic absorption spectrometric method
for the determination of the mass fraction in iron ores.
This Part applies to mass fractions of tin between 0.001% and 0.015% in natural ores,
iron ore concentrates and agglomerates, including sinter products.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition dated applies to this document. For
undated references, the latest edition of the referenced documents (including all
amendments) applies to this document.
GB/T 6739.1, Accuracy (trueness and precision) of measurement methods and
results – Part 1: General principles and definitions (GB/T 6379.1-2004, ISO 5725-
1:1994, IDT)
GB/T 6379.2, Accuracy (trueness and precision) of measurement methods and
results – Part 2: Basic method for the determination of repeatability and
reproducibility of a standard measurement method (GB/T 6379.1-2004, ISO 5725-
1:1994, IDT)
GB/T 6682, Water for analytical laboratory use – Specification and test methods
(GB/T 6682-2008, ISO 3696:1987, MOD)
GB/T 6730.1, Iron ores – Preparation of predried test samples for chemical
analysis (GB/T 6730.1-2016, ISO 7764:2006, MOD)
4.5 Hydrofluoric acid, ρ about 1.13 g/mL.
4.6 Hydrochloric acid, 1+1.
4.7 Hydrochloric acid, 2+3.
4.8 Sulfuric acid, 1+1.
4.9 Ascorbic acid solution, 200 g/l, freshly prepared just prior to use.
4.10 Potassium iodide/ascorbic acid solution: dissolve 90 g of potassium iodide in
water, add 30 g of ascorbic acid and 30 mL of hydrochloric acid (4.3), and dilute with
water to 200 mL. This solution shall be freshly prepared just prior to use.
4.11 Tri-n-octyl phosphine oxide (TOPO)/4-methyl-2 pentanone (MIBK) solution:
dissolve 1 g of TOPO in 100 mL of MIBK.
4.12 Tin standard solution, 200 µg/mL.
Dissolve 0.1 000 g of tin metal (purity > 99.5%) in a platinum crucible (with cover) with
5 mL of hydrochloric acid (4.3). After cooling, transfer the solution to a 500 mL
volumetric flask, add 200 mL of hydrochloric acid (4.6), and dilute to volume with
hydrochloric acid (4.6), and mix. A certified tin standard solution, which is commercially
available, can also be used.
4.13 Tin standard solution, 20 µg/mL.
Transfer 10 mL of tin standard solution (4.12) to a 100 mL volumetric flask, dilute to
volume with hydrochloric acid (4.6) and mix.
5 Apparatus
Unless specified otherwise, ordinary laboratory apparatus, including one-mark pipettes,
graduated pipettes and one-mark volumetric flasks complying with the specifications
of GB/T 12806, GB/T 12807 and GB/T 12808 respectively, and the following.
5.1 Platinum crucible, of capacity 25 ml to 30 ml.
5.2 Platinum rod.
5.3 Separating funnel, 200 mL.
5.4 High temperature furnace, suitable for heating at 1 000°C to 1 020°C.
5.5 Atomic absorption spectrometer, equipped with a dinitrogen oxide/acetylene burner.
Carry out the analysis at least in duplicate in accordance with Annex A, independently,
on one predried test sample.
NOTE: The expression “independently” means that the second and any subsequent result is
not affected by the previous result(s). For the particular analytical method, this condition implies
that the repetition of the procedure is carried out either by the same operator at a different time
or by a different operator including, in either case, appropriate recalibration.
7.2 Test portion
Taking several increments, weigh, to the nearest 0.000 2 g, approximately 1.00 g of
the predried test sample obtained in accordance with 6.2. The test portion should be
taken and weighed quickly to avoid re-absorption of moisture.
7.3 Blank test and check test
7.3.1 Blank test
When the analysis is carried out, carry out the blank test; all reagents are from the
same reagent bottle.
7.3.2 Check test
When the analysis is carried out, carry out the check test on the same type of reference
samples.
7.4 Determination
7.4.1 Decomposition of the test portion
Transfer the test portion (7.2) to a crucible (5.1), moisten with a few drops of water,
add 2 ml of sulfuric acid (4.8) and 6 ml of hydrofluoric acid (4.5), mix well using a
platinum rod (5.2) and wash the rod with water. Using a low-temperature electric
furnace, heat the crucible gently at first, then to white fumes, and continue heating until
no fumes are observed. Place the crucible in a high temperature furnace (5.4) at 1
000°C to 1 020°C for 30 min. Remove the platinum crucible and cool. Add 4.8 g the
mixed solvent (4.1) of sodium carbonate and sodium tetraborate, put on the platinum
cover, place int the high temperature furnace for fusion for 30 min at 1 000°C ~ 1 020°C;
remove to cool. Place the platinum crucible and cover in a 200 ml beaker. Add 50 ml
of hydrochloric acid (4.7), cover the beaker with a watch glass and heat in a water bath
at about 90°C until dissolution of the melt is complete. Wash out the crucible and cover
and cool. In order to avoid the volatilization of tin, they shall be placed in a water bath
at about 90°C.
7.4.2 Treatment of the test solution
Transfer the solution (7.4.1) to a 200 ml separating funnel having a mark indicating 100
......
|