HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (8 Feb 2025)

GB/T 5195.3-2017 English PDF (GB/T 5195.3-2006, GB/T 5195.3-1985)

GB/T 5195.3-2017_English: PDF (GB/T5195.3-2017)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 5195.3-2017English109 Add to Cart 3 days [Need to translate] Fluorspar -- Determination of loss in mass at 105 ℃ -- Gravimetric method Valid GB/T 5195.3-2017
GB/T 5195.3-2006English199 Add to Cart 2 days [Need to translate] Fluorspar -- Determination of loss in mass at 105 Celsius -- Gravimetric method Obsolete GB/T 5195.3-2006
GB/T 5195.3-1985English199 Add to Cart 3 days [Need to translate] Methods for chemical analysis of fluor-spar--The gravimetric method for the determination of loss in mass at 105 Centigrade Obsolete GB/T 5195.3-1985


BASIC DATA
Standard ID GB/T 5195.3-2017 (GB/T5195.3-2017)
Description (Translated English) Fluorspar -- Determination of loss in mass at 105 �� -- Gravimetric method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard D52
Word Count Estimation 5,557
Date of Issue 2017-09-07
Date of Implementation 2018-06-01
Older Standard (superseded by this standard) GB/T 5195.3-2006
Administrative Organization National Steel Standardization Technical Committee (SAC/TC 183)

BASIC DATA
Standard ID GB/T 5195.3-2006 (GB/T5195.3-2006)
Description (Translated English) Fluorspar. Determination of loss in mass at 105 Celsius. Gravimetric method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard D52
Classification of International Standard 73.080
Word Count Estimation 5,547
Date of Issue 2006-08-16
Date of Implementation 2007-01-01
Older Standard (superseded by this standard) GB/T 5195.3-1985
Quoted Standard GB/T 2008
Adopted Standard ISO 4282-1992, MOD
Drafting Organization Baoshan Iron & Steel Co., Ltd.
Administrative Organization Metallurgical Industry Information Standards Institute
Regulation (derived from) China National Standard Approval Announcement 2006 No.9 (Total No.96)
Proposing organization China Iron and Steel Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the determination of fluorite mass loss in the amount of 105��C gravimetric method. This standard applies to the determination of fluorite in the amount of 105��C mass loss measurement range (mass fraction): 0. 02% to 10. 00%.

BASIC DATA
Standard ID GB/T 5195.3-1985 (GB/T5195.3-1985)
Description (Translated English) Methods for chemical analysis of fluor-spar--The gravimetric method for the determination of loss in mass at 105 Centigrade
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H12
Classification of International Standard 73.08
Word Count Estimation 2,248
Date of Issue 1985/5/18
Date of Implementation 1986/3/1
Adopted Standard ISO 4282-1977, IDT
Regulation (derived from) China Announcement of Newly Approved National Standards No. 9, 2006 (No. 96 overall)


GB/T 5195.3-2017 Fluorspar - Determination of loss in mass at 105 ° C - Gravimetric method ICS 73.080 D52 National Standards of People's Republic of China Replacing GB/T 5195.3-2006 Determination of fluorite 105 ℃ quality loss Gravimetric method 2017-09-07 Posted 2018-06-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Foreword GB/T 5195 is divided into 16 parts. --- Part 1. Determination of fluorite calcium fluoride content EDTA titration and distillation - potentiometric titration; --- Part 2. Determination of fluorite carbonate content; --- Part 3. Fluorite 105 ℃ quality determination of the weight method; --- Part 4. Determination of fluorite sulfide content iodometric method; --- Part 5. Determination of total sulfur content of fluorite tube furnace combustion - potassium iodate titration; --- Part 6. Determination of fluorite content of phosphorus spectrophotometry; --- Part 7. Determination of zinc content of fluorite; atomic absorption spectrometry; --- Part 8. Determination of fluorite silica content; --- Part 9. Determination of weight loss of fluorite burning weight method; --- Part 10. Determination of iron content of fluorite phenanthroline spectrophotometry; --- Part 11. Determination of fluorspar content; Periodate spectrophotometry; --- Part 12. Determination of arsenic content of fluorite; atomic fluorescence spectrometry; --- Part 13. Determination of aluminum content of fluorite EDTA titration method; --- Part 14. Determination of magnesium content of fluorite flame atomic absorption spectrometry; --- Part 15. Determination of calcium, aluminum, silicon, phosphorus, sulfur, potassium, iron, barium and lead contents of fluorite; wavelength dispersive X - ray fluorescence spectrometry; --- Part 16. Determination of fluorite silicon, aluminum, iron, potassium, magnesium and titanium content Inductively coupled plasma atomic emission spectrometry. This section GB/T 5195 Part 3. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 5195.3-2006 "Determination of fluorite mass loss of 105 ℃ weight method." This section and GB/T 5195.3- Compared to.2006, the main technical changes are as follows. --- Updated normative references (see Chapter 2, Chapter 2 of the.2006 edition); --- Increased measuring instruments (see 5.2); --- Modify the determination of the number of samples, the "should be weighed three samples for determination" should read "two samples should be weighed" (see 7.1,.2006 edition 6.1); --- Increasing the value of the calculation results rounding (see 8.2). This part is proposed by China Iron and Steel Association. This part of the National Standardization Technical Committee Steel (SAC/TC183) centralized. This section drafting unit. Baoshan Iron and Steel Co., Ltd., Metallurgical Industry Information Standards Institute. The main drafters of this section. Liu Xiaoping, Yu Yongbo, Xiapei Pei, Lu Chunsheng. This part replaces the standards previously issued as. --- GB/T 5195.3-1985, GB/T 5195.3-2006. Determination of fluorite 105 ℃ quality loss Gravimetric method 1 Scope GB/T 5195 provisions of this part of the gravimetric determination of fluorite in 105 ℃ quality loss method. This section applies to the determination of the quality of fluorite in 105 ℃. Measuring range (mass fraction) .0.02% ~ 10.00%. 2 Normative references The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 8170 rounded repair rules and limit values of the representation and judgment GB/T 22564 fluorite sampling and sample preparation 3 principle The sample was dried at 105 ℃ ± 2 ℃, the determination of the quality of the loss. Its mass loss is equivalent to moisture and other volatile components at that temperature content. 4 Reagents and materials 4.1 weighing bottle. About 40mm high, diameter of about 65mm. 4.2 enamel or glass dish height of about 40mm, rectangular about 300mm ×.200mm or circular diameter of about 250mm. 5 instruments 5.1 electric oven, the temperature can be controlled 105 ℃ ± 2 ℃. 5.2 Balance. 6 sampling and sample preparation In accordance with the provisions of GB/T 22564 sampling and sample preparation. 7 Analysis steps 7.1 The number of tests For the same sample, two samples shall be weighed for determination. ......

Similar standards: GB/T 5195.11-2021  GB/T 5195.17-2018  
Similar PDFs (Auto-delivered in 9 seconds): GB/T 5195.12-2016  GB/T 5195.1-2017  GB/T 3286.9-2014  GB/T 3286.8-2014