GB/T 5193-2007_English: PDF (GBT5193-2007)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Related Standard | Status | PDF |
GB/T 5193-2007 | English | 319 |
Add to Cart
|
3 days
|
Method of ultrasonic inspection for wrought titanium and titanium alloy products
|
GB/T 5193-2007
| Obsolete |
GB/T 5193-2007
|
Standard ID | GB/T 5193-2007 (GB/T5193-2007) | Description (Translated English) | Method of ultrasonic inspection for wrought titanium and titanium alloy products | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | H64 | Classification of International Standard | 77.120 | Word Count Estimation | 8,885 | Date of Issue | 2007-11-23 | Date of Implementation | 2008-06-01 | Older Standard (superseded by this standard) | GB/T 5193-1985 | Quoted Standard | JB/T 10061 | Drafting Organization | Baoji Titanium Group Ltd. | Administrative Organization | National Nonferrous Metals Standardization Technical Committee | Regulation (derived from) | China National Standard Approval Announcement2007 No.12 (Total No.112) | Proposing organization | China Nonferrous Metals Industry Association | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This standard specifies the titanium and titanium alloy products ultrasonic testing requirements, detection equipment, reference block, flaw, acceptance, inspection records and reports. This standard applies to the cross-sectional thickness greater than 6 mm ~ 230 mm ultrasonic testing of titanium and titanium alloy products. |
GB/T 5193-2007
Method of ultrasonic inspection for wrought titanium and titanium alloy products
ICS 77.120
H64
National Standards of People's Republic of China
Replacing GB/T 5193-1985
Titanium and titanium alloy products ultrasonic flaw detection method
Posted 2007-11-23
2008-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB/T 5193-1985 "titanium and titanium alloy products ultrasonic flaw detection method."
This standard compared with GB/T 5193-1985, mainly in the following changes.
--- Expand the scope of cross-sectional thickness greater than titanium and titanium alloy products, ultrasonic flaw detection of 6mm;
--- Method category increased 6mm ~ 45mm flooding bars should be preferred focusing method;
--- Increases the surface roughness R Rao ≤3.2μm;
--- For the A-mode pulse reflection equipment requirements to meet the JB/T 10061 "A-mode pulse reflection type ultrasonic probe
Injury general technical conditions "requirements;
--- Increasing the diameter of 8mm ~ 20mm, operating frequency of 2.5MHz ~ 5MHz duals, recommended for 6mm ~
20mm thick planar contact method product testing;
--- Increased when both parties agree to allow the use of frequencies below 2.5MHz or a particular type of probe;
--- Burial depth of the flat bottom hole made appropriate changes;
--- Modify the status of the device during testing requirements;
--- Modify the requirements immersion testing pulse repetition frequency;
--- For no alarm system, manual scan, scan speed recommended, to not more than 127mm/s;
--- Increased suppression control requirements;
--- Modify part of Table 2;
--- Level of acceptance increases the Notes;
--- Increased inspection records and reports.
Appendix A of this standard is a normative appendix.
The standard proposed by China Nonferrous Metals Industry Association.
This standard Nonferrous Metals by the National Standardization Technical Committee.
This standard by the Baoji Titanium Group Ltd., Baoji Titanium Industry Co., Ltd. is responsible for drafting.
The main drafters of this standard. Maxiao Huai, Huang Yongguang, Guo Yongqing, Xintian Ning, Wang Yongmei, Wang Weiqi.
This standard replaces the previous version of the release of case.
--- GB/T 5193-1985.
Titanium and titanium alloy products ultrasonic flaw detection method
1 Scope
This standard specifies the titanium and titanium alloy products ultrasonic testing requirements, testing equipment, test block, testing, inspection, inspection records
And reporting.
This standard applies to the cross-sectional thickness greater than 6mm ~ 230mm titanium and titanium alloy products, ultrasonic flaw detection.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
JB/T 10061 A-mode pulse reflection type ultrasonic flaw detector General technical requirements
3 Requirements
3.1 Objective
Mainly for internal flaw detection of titanium and titanium alloy products, such as cracks, holes, loose and other exposed or exposed to the surface
Discontinuity tissue.
3.2 Method category
This standard specifies the use of ultrasonic flaw detection pulse longitudinal wave reflection method. If necessary, may also be agreement between shear wave or other
Type, immersion or contact method can be. 6mm ~ 45mm flooding bars should be preferred focusing method.
3.3 staff
Operators should reach ministerial or equivalent level and above grade Ⅰ learn NDT personnel qualification and issuing inspection reports and explain people
Members should meet ministerial or equivalent level grade Ⅱ learn and staff qualifications.
3.4 Surface
3.4.1 is the
|