GB/T 39752-2021English505 Add to Cart 0--9 seconds. Auto-delivery Safety requirements and test specifications of electric vehicle conductive supply equipment Valid GB/T 39752-2021

BASIC DATA
Standard ID GB/T 39752-2021 (GB/T39752-2021)
Description (Translated English) Safety requirements and test specifications of electric vehicle conductive supply equipment
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard T35
Classification of International Standard 43.040.99
Word Count Estimation 34,329
Date of Issue 2021-03-09
Date of Implementation 2021-10-01
Drafting Organization State Grid Co., Ltd., China Electricity Council, Nari Group Co., Ltd., State Grid Electric Power Research Institute Co., Ltd., State Grid Electric Vehicle Service Co., Ltd., Xu Ji Power Co., Ltd., China Electric Power Research Institute Co., Ltd., State Grid Smart Energy Transportation Technology Innovation Center (Suzhou) Co., Ltd., State Grid Beijing Electric Power Company, State Grid Jiangsu Electric Power Co., Ltd., State Grid Jiangxi Electric Power Co., Ltd. Electric Power Research Institute, State Grid Hunan Electric Power Co., Ltd., State Grid Chongqing City Electric Power Company, State Grid Intelligent Technology Co., Ltd., China Automotive Technology Research Center Co., Ltd., Guangdong Power Grid Co., Ltd. Electric Power Research Institute, Shenzhen Aotexun Power Equipment Co., Ltd., Nanjing Nengrui Power Technology Co., Ltd., Changyuan Shenrui Relay Automation Co., Ltd., Huawei
Administrative Organization China Electricity Council
Regulation (derived from) National Standard Announcement No. 3 of 2021
Proposing organization China Electricity Council
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

Standards related to: GB/T 39752-2021

GB/T 39752-2021
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 43.040.99
T 35
Safety Requirements and Test Specifications of
Electric Vehicle Conductive Supply Equipment
ISSUED ON: MARCH 9, 2021
IMPLEMENTED ON: OCTOBER 1, 2021
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of
China.
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Normative References ... 5 
3 Terms and Definitions ... 6 
4 Safety Requirements ... 11 
5 Test Guidelines ... 25 
6 Test Methods ... 30 
Appendix A (informative) Identification Symbols Used on Conductive Supply
Equipment of Electric Vehicles ... 42 
Appendix B (normative) Safety Test Items of Conductive Supply Equipment of
Electric Vehicles ... 44 
Bibliography ... 46 
Safety Requirements and Test Specifications of
Electric Vehicle Conductive Supply Equipment
1 Scope
This Standard specifies the safety requirements, test guidelines and test methods of
electric vehicle conductive supply equipment (hereinafter referred to as “conductive
supply equipment”).
This Standard is applicable to various types of conductive supply equipment with a
rated output voltage of 1,000 V AC or 1,500 V DC and below, including conductive
supply equipment of Charging Mode 2, Charging Mode 3 and Charging Mode 4;
conductive supply equipment that are not used for public purposes and used under
special conditions (such as: explosion-proof conductive supply equipment, liquid-
cooled conductive supply equipment and conductive supply equipment used in
plateaus above 2,000 m above sea level, etc.) are also applicable to this Standard,
and the requirements of relevant standards need to be combined here.
In terms of independent electrical accessories and auxiliary materials (such as:
connecting devices, cables and insulating materials, etc.) of conductive supply
equipment, this Standard needs to be jointly used in accordance with specific product
standards.
This Standard involves serious damage to the equipment and severe personal hazards
caused by hazards of electric shock, energy, machinery, high temperature, fire
spreading, sound pressure and loss of control under the circumstance where the
conductive supply equipment complies with the correct procedures of use, but might
have operational errors.
This Standard does not involve the following content:
---Safety requirements related to transportation, packaging, improper installation
and application;
---Requirements for electromagnetic compatibility;
---Requirements for information security;
---Safety problems caused by vandalism and other purposeful acts;
---Other functional and performance requirements that are not related to safety.
[GB 4943.1-2011, Definition 1.2.9.5]
3.16 Overvoltage Category
Overvoltage category refers to the expression of transient overvoltage conditions
through numerals.
NOTE 1: use I, II, III and IV to express overvoltage category.
NOTE 2: Definition 3.10 of GB/T 16935.1-2008 is modified.
3.17 Equipment Safety Classification
Equipment safety classification refers to the classification in accordance with the
protective measures against electric shock provided by the conductive supply
equipment.
3.17.1 Class I equipment
Class I equipment refers to the equipment that not only relies on the basic insulation
for protection against electric shock, but also includes an additional safety measure,
that is, connecting the conductive part that is vulnerable to electric shock to the
protective (earthing) conductor in the fixed wiring of the equipment, so that the easily
accessible conductive part will not become a live part when the basic insulation fails.
[GB/T 4776-2017, Definition 2.3.3.2]
3.17.2 Class II equipment
Class II equipment refers to the equipment that not only relies on the basic insulation
for protection against electric shock, but also include an additional safety measure (for
example, double insulation or reinforced insulation), but does not specify the protective
earthing or equipment dependent conditions.
[GB/T 4776-2017, Definition 2.3.3.3]
3.18 Pollution
Pollution refers to the adhesion of external substances, for example, solids, liquids or
gases (ionized gases) that may reduce the dielectric strength and surface resistivity.
NOTE: Definition 3.11 of GB/T 16935.1-2008 is modified.
3.19 Pollution Degree
Pollution degree refers to the expression of the expected degree of pollution in the
micro-environment through figures.
NOTE: Definition 3.13 of GB/T 16935.1-2008 is modified.
4.1.2 Pollution degree
The pollution degree of the conductive supply equipment is the pollution degree of the
external environment, which shall comply with the requirements of Table 1. When the
indoors are exposed to a polluted industrial environment, the pollution degree shall be
PD3.
4.1.3 Protection degree
The degree of protection of the conductive supply equipment by enclosure shall comply
with the requirements of Table 1. The degree of protection of the conductive supply
interface shall comply with the requirements specified in GB/T 20234.1-2015.
4.1.4 UV exposure
In terms of outdoor conductive supply equipment, the polymer material of the enclosure
and the exposed sealing material shall have sufficient resistance to material
degradation caused by ultraviolet radiation. There shall not be obvious deformation,
cracks or ruptures, and the normal use shall not be affected.
4.2 Structure
4.2.1 General requirements
The structure of the conductive supply equipment includes enclosure, partition, door
blocking device and hinge. The connection and splicing shall have sufficient
mechanical strength to withstand the stress encountered under normal use and fault
conditions. The accessible parts of the structure of the conductive supply equipment,
such as: edges, protrusions, corners, holes, shields and handles, shall be smooth, and
shall not cause injury during the normal use.
4.2.2 Enclosure material
The enclosure material of the conductive supply equipment shall be able to withstand
the mechanical stress, electrical stress, thermal stress and environmental pressure
generated under the specified conditions of use.
4.2.3 Handle and manual control device
The handles, knobs, fixtures, joysticks and similar parts shall be firmly installed, and
shall not become loosened during the normal use.
4.2.4 Connection and splicing
All connections and splicing of the conductive supply equipment shall be mechanically
firm and electrically continuous, so as to avoid mechanical damage. All wires used for
external connections, connections between parts and internal connections of parts,
conductors that are in contact with each other, or exposed live parts shall have an
4.2.7 Electrical parts
4.2.7.1 Charging module
The input and output of the charging module used by the conductive supply equipment
shall be isolated. There shall be measures of double insulation or reinforce insulation
between the directly accessible low-voltage circuit part of the charging module and the
dangerous voltage parts, such as: the input and output, etc. The charging module shall
have input and output protection functions.
The enclosure of the charging module installed in the conductive supply equipment
shall be well-connected to the protective earthing of the conductive supply equipment,
and comply with the requirements of stipulations regarding protective connection and
protective earthing of class I equipment in 4.3.2.2.1.
4.2.7.2 Mechanical switchgear
The rated insulation voltage of the switchgear selected for the conductive supply
equipment shall be not less than the rated working voltage of the conductive supply
equipment, and not less than the working circuit voltage. The rated current shall be not
less than 1.25 times of the rated current of the working circuit.
The conductive supply equipment shall provide one or more mechanical switchgears
(such as: switches and disconnecting switches, contactors, circuit breakers and relays,
etc.) for each power supply that carries dangerous voltage or exceeds dangerous
energy or might cause dangerous voltage and energy. The requirements for the
switchgear are as follows:
---For DC output, the switchgear shall be able to simultaneously disconnect the
anode and cathode;
---For single-phase AC output, a disconnecting device that allows simultaneous
disconnection of two poles shall be provided in accordance with the stipulations;
---For three-phase AC output, a disconnecting device that allows simultaneous
disconnection of four poles shall be provided in accordance with the stipulations.
4.2.7.3 Connecting devices for charging
4.2.7.3.1 Temperature monitoring
The temperature monitoring function of the connecting device used for charging shall
comply with the requirements specified in 9.1 of GB/T 18487.1-2015.
4.2.7.3.2 Blocking device
The blocking device of the connecting device used for charging shall comply with the
requirements specified in 9.6 of GB/T 18487.1-2015.
Modes used for protective connection include:
---Directly through metal contact;
---Through other conductive parts, which will not be removed when the
conductive supply equipment or components are used in accordance with
the stipulations;
---Through special protective connecting conductors;
---Through other metal components of the conductive supply equipment.
When the accessible conductive parts fail, the protective connection shall
always remain effective, unless the superior protection device cuts off the
power supply of this part.
b) Protective earthing
The external protective earthing conductor of the conductive supply
equipment shall provide a connection mode close to the corresponding live
conductor connection terminal, and this connection mode shall be anti-
corrosion. After the conductive supply equipment is energized, the external
protective earthing conductor shall always maintain connected. If the external
protective earthing conductor passes through a plug and socket or similar
disconnecting device, then, these connections shall not be disconnected,
unless the power supply of the protected part can also be disconnected at the
same time.
If the external protective earthing is connected through a wiring harness, it
shall be ensured that the external protective earthing conductor is the last one
in the wiring harness to be disconnected. When the protective earthing
conductor is damaged or disconnected, the contact current of the enclosure
of the conductive supply equipment shall comply with the requirements
specified in 11.2 of GB/T 18487.1-2015.
The application position and / or identification and indication of the protective
earthing conductor in the conductive supply equipment shall be easily
identified. The size of the protective earthing conductor shall comply with the
requirements specified in 7.4 of GB/T 18487.1-2015. The metal enclosures
and partitions used to isolate live conductors, the metal enclosures of
electrical components and the metal handles shall all be effectively earthed,
and the continuity resistance shall be not greater than 0.1 .
4.3.2.2.2 Class II equipment protection - double or reinforced insulation
The protection of the conductive supply equipment as class II equipment shall provide
insulation measures between the live parts and the accessible surface in accordance
The insulation resistance of the conductive supply equipment shall comply with the
requirements specified in 11.3 of GB/T 18487.1-2015.
4.3.6 Dielectric strength
4.3.6.1 Power frequency withstand voltage
The dielectric strength of the conductive supply equipment shall comply with the
requirements specified in 11.4 of GB/T 18487.1-2015.
4.3.6.2 Impulse withstand voltage
The impulse withstand voltage of the conductive supply equipment shall comply with
the requirements specified in 11.5 of GB/T 18487.1-2015.
4.4 Protection against Energy Hazard
4.4.1 Loss of voltage of functional circuit
The voltage between any accessible live parts, and between the accessible live parts
and the protective earthing conductor in the functional circuit of the conductive supply
equipment shall drop to below 42.4 V AC or 60 V DC within 1 s.
4.4.2 Loss of voltage of power supply output
Within 1 s after the conductive supply equipment is cut off, the voltage between the
power cords of its output terminals or between the power cord and the protective
earthing conductor shall drop to below 42.4 V AC or 60 V DC.
4.5 Protection against Charging Hazard
4.5.1 Insulation self-check
The conductive supply equipment adopting Charging Mode 4 shall be equipped with a
function of insulation detection of the DC output circuit; the function of insulation
detection shall comply with the requirements specified in B.4.1 of GB/T 18487.1-2015.
4.5.2 Discharge
After the insulation detection and charging, the conductive supply equipment adopting
Charging Mode 4 shall discharge the voltage of the charging output circuit in
accordance with the requirements specified in B.4.2 and B.4.3 of GB/T 18487.1-2015.
4.5.3 Pre-charging
The conductive supply equipment adopting Charging Mode 4 shall equipped with a
function of pre-charging. After charging is actuated and the electric vehicle closes the
DC contactor on the vehicle side, the conductive supply equipment shall detect the
battery voltage and determine whether this voltage is normal. After the conductive
or current, the conductive supply equipment shall stop charging.
4.5.10 Door opening protection
The conductive supply equipment shall be equipped with a function of door opening
protection. When the cabinet door of the conductive supply equipment is opened, if the
live part is exposed, the integrated conductive supply equipment shall simultaneously
cut off the power input and DC output; the split conductive supply equipment shall cut
off the power input and DC output of the corresponding part.
4.5.11 Emergency stop protection
The conductive supply equipment adopting Charging Mode 4 shall have a function of
emergency stop. The conductive supply equipment adopting Charging Mode 3 may be
equipped with an emergency stop device.
4.6 Hazards of Overheating and Fire
4.6.1 Cause overheating
When the conductive supply equipment is normally working, overheating caused by
the following factors might reduce the electrical, mechanical, insulation or other
performances, and lead to hazards.
---Accessible parts that exceed the safety temperature;
---Components, parts, insulation and plastic materials that exceed a specific
temperature;
---Structures and installation surfaces that exceed a specific temperature.
4.6.2 Allowable surface temperature
The accessible surface temperature of the conductive supply equipment shall comply
with the requirements specified in 11.6.3 of GB/T 18487.1-2015.
4.6.3 Over-temperature protection
The conductive supply equipment shall have a function of internal over-temperature
protection. When the internal temperature reaches the set value for protection, the
power shall be reduced or the output shall be stopped.
4.6.4 Hazard of ignition and fire spreading
Under the normal working conditions and single fault condition, the conductive supply
equipment shall limit the maximum temperature of the components or limit the effective
power of the circuits by using appropriate materials and structures, for example, by
using flame-retardant materials, insulation or providing adequate barriers, so as to
equipment.
4.9 Identification and Indication
4.9.1 Identification
The conductive supply equipment shall be marked with product identification and
warning sign in accordance with the stipulations. The use of graphic symbols in the
identification should comply with the relevant requirements specified in Appendix A.
Under the normal conditions of use, the identification of the conductive supply
equipment shall maintain clear and identifiable and be able to withstand corrosion.
4.9.2 Product identification
The conductive supply equipment shall be marked with product identification, and the
content of the product identification shall comply with the requirements specified in
Chapter 16 of GB/T 18487.1-2015. After the conductive supply equipment is correctly
installed, the production identification shall be directly visible from the outside, or
directly visible behind a cover or door that the operation personnel can open without
the use of tools. The product identification shall not be applied to parts that can be
removed by the operation personnel without tools. For rack or panel-embedded
conductive supply equipment, it is allowed to see the identification after being removed
from the rack or panel.
4.9.3 Warning sign
On the surface of the conductive supply equipment, or after opening any protective
measures (such as: door and cover) leading to dangerous parts, a warning sign shall
be provided in a clearly visible position. The warning sign shall be clear and distinct. If
a warning sign is for a specific part of the equipment, then, it shall be marked on the
part or nearby.
4.9.4 Indication
The conductive supply equipment shall be able to provide the following two indications:
---An integrated and directly visible or audible indication;
---An electrical or electronic indication that can be remotely accessed and used,
for example, the provided signal relay contacts, open-collector output or
sending messages to the communication system on the network.
5 Test Guidelines
5.1 General Rules
The conductive supply equipment shall go through the tests of items listed in Appendix
conductive supply equipment. Except for the test under the single fault
condition, the overcurrent protection device is not allowed to operate in other
test items under the normal conditions.
5.2.3 Load conditions
Resistive load is recommended for the test, which shall be carried out under the most
unfavorable load conditions. The AC output port or DC output port of the conductive
supply equipment shall be able to be adjusted to the maximum rated output power or
current; select the most unfavorable condition of the two for the test. For ports that are
scheduled to be connected to the battery, under the circumstance where the test result
might be affected, the battery may be used as a replacement of the load, or the battery
and the load may be tested in parallel. However, the traceability and reproducibility of
the test results need to be evaluated.
Unless it is otherwise specified in this Standard, the load conditions shall be maintained
for a certain time in accordance with the following requirements:
---For continuous operation, maintain the load conditions until stable conditions
are established;
---For intermittent operation, follow the nominal “On” and “Off” cycles, until stable
conditions are established;
---For short-term operation, reach the nominal operating time.
5.3 Test Sequence
Unless it is otherwise specified, in principle, the test of all test items in this Standard
shall be carried out in accordance with the following sequence:
a) Test carried out under non-energized conditions;
b) Test carried out under energized conditions:
---Test of normal working conditions;
---Test of analog fault conditions (single fault condition test);
---Possibly destructive test.
5.4 Test Instruments
The measuring range and precision of the used instruments and meters shall be
selected in accordance with the actual conditions of measurement, and shall be within
the validity period of the metrological certification:
---The measured value should be within the range of 1/5 ~ 4/5 of the measuring
5.7 Single Fault Condition Test
5.7.1 Basic requirements
The test under single fault condition is used to prevent the hazards caused by the
reasonably expected fault conditions. These fault conditions might occur during normal
use, or during the expected mis-operation. For a specific fault condition, if it is indeed
proved that it will not lead to hazards, or if this Standard specifies an alternative test
method, then, the fault test may be omitted. The output terminal of the conductive
supply equipment shall ensure that under a single fault, the internal dangerous voltage
or energy will not be transmitted to the operation personnel or the surrounding
environment through the charging connection device.
The single fault condition test merely sets one fault condition at a time. Multiple fault
conditions shall not be simultaneously set, however, if there is a casual relationship
between them, then, they shall be successively conducted. The multiple fault condition
test may be performed on different samples; or it may also be performed on the same
sample, as long as the previous failure can be repaired or does not affect the
subsequent test results.
5.7.2 Qualification criteria after applying fault conditions
5.7.2.1 Criteria for protection against the hazard of electric shock
After applying a single fault condition, the conductive supply equipment shall
simultaneously satisfy the following requirements regarding the protection against the
hazard of electric shock:
---Measure and confirm that there is no hazard of electric shock in accessible
conductive parts;
---Comply with the requirements of the insulation strength test;
---Check whether there is an open circuit connected between the protective
earthing terminal and the protective earthing conductor of the conductive supply
equipment during the test; the enclosure of the equipment shall not be earthed
in the remaining parts;
---Check whether the enclosure of the conductive supply equipment is damaged;
ensure that the hazardous live parts and the mechanically hazardous parts are
not touched.
5.7.2.2 Criteria for protection against the hazard of fire spreading
After applying a single fault condition, the conductive supply equipment shall not splash
molten metal, burning insulating materials, and flame or flameless particles.
5.7.2.3 Criteria for protection against the hazard of ejected parts
6.1.2 Accessibility test of hazardous live parts
6.1.2.1 Test of protection against electric shock
Use an articulated test finger (test tool B) that complies with GB/T 16842 for the test.
Check the conductive supply equipment: the hazardous live parts that are directly
accessible or parts that might become hazardous live parts in the case of a fault shall
be inaccessible, and the protection level complies with the requirements specified in
7.2 of GB/T 18487.1-2015.
6.1.2.2 Test of protection against unexpected voltage
Check that when the hazardous live parts are exposed and accessible due to
behaviors and activities like opening the cabinet door of the conductive supply
equipment, the conductive supply equipment shall cut off the output within 1 s.
6.1.3 Insulation test
6.1.3.1 Insulation resistance test
Before the insulation resistance test, the connection of the external power supply to
the conductive supply equipment shall be firstly cut off. Close the input and output
circuit switches. Between each independent live circuit of the electrical connection, and
between each independent live circuit and the protective earthing conductor (metal
enclosure) of the conductive supply equipment, apply the DC voltage specified in Table
5; check that the insulation resistance of the conductive supply equipment shall be not
less than 10 M.
6.1.3.2 Insulation self-check function test
For the conductive supply equipment adopting Charging Mode 4, choose the test
resistance Rt (the test resistance precision does not exceed ± 3%) to be 100 /V < Rt
≤ 500 /V or Rt ≤ 100 /V; the test voltage is the rated output voltage of the conductive
supply equipment. Between the DC output DC+ and the protective earthing PE, or
between the DC output DC and the protective earthing PE, respectively perform
asymmetric insulation test and symmetric insulation test. Check that the insulation
detection function of the conductive supply equipment shall comply with the
requirements specified in B.4.1 and B.4.2 of GB/T 18487.1-2015.
6.1.4 Dielectric strength test
The dielectric strength test shall be carried out only after the conductive supply
equipment is qualified in the insulation resistance test. Between each independent live
circuit of the electrical connection, and between each independent live circuit and the
protective earthing conductor (metal enclosure) of the conductive supply equipment,
apply the power frequency AC voltage (DC voltage may also be used, and the test
voltage is 1.4 times of the effective value of the AC voltage) specified in Table 5 for a
same or different material as the phase conductor shall be measured with a measuring
instrument, and shall comply with the requirements specified in 7.4 of GB/T 18487.1-
2015.
6.1.7.2 Earthing resistance and continuity test
When the enclosure of the conductive supply equipment is used as part of the
protective earthing connection, it shall be able to continuously provide earthing
continuity. Through an earthing resistance tester or digital low-resistance tester of no
less than 10 A, measure the resistance between any point that shall be earthed and
the total earthing of the conductive supply equipment, which shall be not greater than
0.1 . The number of measurement points shall be no less than 5. If the measurement
points are coated with anti-corrosion paint, the anti-corrosion paint needs to be
scrapped off to expose the non-insulating materials, then, conduct the test.
6.2 Residual Voltage Tester after Output is Disconnected
Connect the conductive supply equipment to the load; set to the rated power; load and
run; reach a stable state. Simulate to stop charging; check that the output port of the
conductive supply equipment adopting Charging Mode 4 shall drop to below 60 V DC
within 1 s; check that the output port of the conductive supply equipment adopting
Charging Mode 2 or Charging Mode 3 shall drop to below 42.4 V AC within 1 s.
6.3 Charging Test
6.3.1 Input safety test
6.3.1.1 Input overvoltage protection test
Connect the conductive supply equipment to the load; set to the rated power; load and
run; reach a stable state. Adjust the input power supply voltage of the conductive
supply equipment to be higher than 115% of the rated voltage. Check that the
conductive supply equipment shall activate the input overvoltage protection function,
cut off the output and issue a fault alarm.
6.3.1.2 Input undervoltage protection test
Connect the conductive supply equipment to the load; set to the rated power; load and
run; reach a stable state. Adjust the input power supply voltage of the conductive
supply equipment to be lower than the undervoltage setting value of the conductive
supply equipment; the undervoltage setting value shall be not greater than 85% of the
rated voltage value. Check that the conductive supply equipment shall activate the
input undervoltage protection function and issue a fault alarm.
6.3.1.3 Input reverse polarity test
For the conductive supply equipment adopting DC power supply (for example,
...