HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (22 Mar 2025)

GB/T 3606-2025 English PDF (GB/T 3606-2001: Older version)

Search result: GB/T 3606-2025 (GB/T 3606-2001 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 3606-2025English519 Add to Cart 5 days [Need to translate] Domestic biogas stove Valid GB/T 3606-2025
GB/T 3606-2001English120 Add to Cart 0--9 seconds. Auto-delivery Domestic biogas stove Valid GB/T 3606-2001
GB/T 3606-1983English199 Add to Cart 2 days [Need to translate] Biogas furnace of family Obsolete GB/T 3606-1983


BASIC DATA
Standard ID GB/T 3606-2025 (GB/T3606-2025)
Description (Translated English) Domestic biogas stove
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y68
Classification of International Standard 97.040
Word Count Estimation 26,281
Date of Issue 2025-01-24
Date of Implementation 2025-08-01
Administrative Organization National Technical Committee for Standardization of Biogas (SAC/TC 515)
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration


GB/T 3606-2025.Household biogas stoves ICS 97.040 CCSY68 National Standard of the People's Republic of China Replace GB/T 3606-2001 Household biogas stove Released on 2025-01-24 2025-08-01 Implementation State Administration for Market Regulation The National Standardization Administration issued Table of Contents Preface III 1 Range 1 2 Normative references 1 3 Terms and Definitions 1 4 Product Categories 2 4.1 Types of stoves 2 4.2 Model compilation method 2 5 Technical Requirements 3 5.1 Basic design parameters and requirements 3 5.2 Performance requirements 3 5.3 Structural requirements 5 5.4 Material requirements 6 6 Test methods 7 6.1 Laboratory conditions 7 6.2 Experimental biogas 7 6.3 Test instruments 7 6.4 Test equipment 8 6.5 Cooking Appliance Test Status 8 6.6 Air tightness test 9 6.7 Heat load test 9 6.8 Combustion condition test 10 6.9 Temperature rise test 13 6.10 Electric ignition device test 14 6.11 Thermal efficiency test 14 6.12 Durability test 15 6.13 Vibration test 15 6.14 Drop test 16 6.15 Packaging pressure test 16 6.16 Structural test 16 6.17 Material testing 16 7 Logo, packaging 16 7.1 Sign 16 7.2 Packaging 17 7.3 Installation Instructions 17 Appendix A (Informative) Provisions on the content of nitrogen oxides [NOx (α=1)] in the flue gas of household biogas stoves 18 A.1 Nitrogen oxide emissions from household biogas stove combustion flue gas 18 A.2 Test instruments 18 A.3 Test conditions 18 A.4 Test status 18 A.5 Test method 18 Appendix B (Informative) Embedded stove installation hole dimensions 19 Preface This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 3606-2001 "Household Biogas Cookers". Compared with GB/T 3606-2001, except for structural adjustments and editorial changes, In addition to the above, the main technical changes are as follows. --- Added household biogas stoves, embedded biogas stoves, benchmark status, low calorific value Wobac number, rated heat load (rated heat flow), actual measurement Heat load (measured heat flow), biogas supply pressure, rated biogas supply pressure, burner, main burner, small fire burner Terms and definitions (see Chapter 3); --- Added stove types (see 4.1); --- Changed the method of compiling stove models (see 4.2, 3.1 of the.2001 edition); --- Changed the basic design parameters and requirements (see 5.1, 3.3.1 of the.2001 edition); --- Changed the requirements for the measured heat load conversion of two-burner stoves (see 5.2.2, 3.3.2 of the.2001 edition); --- Deleted the appearance requirements (see 4.1 of the.2001 edition); --- Added flameout protection devices for stoves used for centralized biogas supply and air tightness requirements for automatic control valves (see 5.1.4,5.2.1); --- Added quality requirements for biogas sources (see 5.1.5); --- Changed the requirements for combustion conditions (see 5.2.3, 4.4 of the.2001 edition); --- Changed the technical requirements and test methods for the maximum normal temperature rise (see 5.2.4, 6.9, 4.9, 5.7.10 of the.2001 edition); --- Changed the technical requirements for electric ignition devices (see 5.2.5, 4.8 of the.2001 edition); --- Changed the technical requirements for thermal efficiency (see 5.2.6, 4.5 of the.2001 edition); --- Changed the durability requirements (see 5.2.7, 4.11 of the.2001 edition); --- Added technical requirements and test methods for drop resistance and packaging pressure resistance (see 5.2.9, 5.2.10); --- Changed the structural requirements (see 5.3, 4.12 of the.2001 edition); --- Material requirements for cooking appliances are changed to material performance requirements (see 5.4, 4.13 of the.2001 edition); --- Changed the room temperature requirements in the test room conditions (see 6.1.1, 5.1 of the.2001 edition); --- Changed the wind speed requirements in the test room conditions (see 6.1.2, 5.1 of the.2001 edition); --- Added the distance requirements between stoves and walls and other obstructions in the stove test (see 6.5); --- The test method for thermal efficiency has been changed (see 6.11, 5.7.6 of the.2001 edition); --- Added the calculation formula of measured heat load and the calculation formula of measured converted heat load (see 6.7); --- Changed the calculation formula and test method for the percentage concentration of CO in dry flue gas (see 6.8.2, 5.7.7 of the.2001 edition); --- Added the geometric parameters, quality parameters and surface color parameter requirements of the pot used in the biogas stove test, specific requirements for the test pot and heating Water volume (see Table 8); --- Deleted sampling and inspection (see Chapter 6 of the.2001 edition); --- Changed the technical requirements for marking and packaging (see 7.1, 7.2,.2001 edition 7.1, 7.2); --- Deleted transportation and storage (see 7.3 and 7.4 of the.2001 edition). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the Ministry of Agriculture and Rural Affairs of the People's Republic of China. This document is under the jurisdiction of the National Biogas Standardization Technical Committee (SAC/TC515). This document was drafted by. Chengdu Biogas Research Institute of the Ministry of Agriculture and Rural Affairs, Sichuan Zhongzhao Bioenergy Testing Co., Ltd., Agricultural Agricultural The village agricultural ecology and resource protection station, Geyi (Anhui) Circular Economy Development Co., Ltd., Shanxi Agricultural Ecological Protection and Resource Zoning Center Center, Jincheng Modern Agriculture Development Center. The main drafters of this document are. Wang Chao, Ran Yi, Jiang Hongtao, Liu Yujia, Zhang Jichuan, Xu Wenyong, Chen Jia, Li Bingfeng, Liu Zhigang, Liu Xiangyi, Xi Jiang, Long Ling, Jing Kun, Wang Juanjuan, Tian Xu, Chen Ziai, Ding Zili, and Wang Yanping. The previous versions of this document and the documents it replaces are as follows. --- First published as GB/T 3606-1983 in 1983 and first revised in.2001; ---This is the second revision. Household biogas stove 1 Scope This document specifies the product classification, technical requirements, marking and packaging of household biogas stoves and describes the test methods. This document applies to household biogas stoves with a single burner rated heat load not exceeding 3.86kW. 2 Normative references The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 191 Pictorial markings for packaging, storage and transportation GB/T 1019-2008 General rules for packaging of household and similar electrical appliances GB/T 3768-2017 Acoustics Sound Pressure Method for Determination of Sound Power Level and Sound Energy Level of Noise Source Using Envelope Measurement Surface Above Reflecting Surface Simple method GB/T 4857.3 Basic tests for packaging and transport packages Part 3.Static load stacking test method GB 16410-2020 Household gas stoves 3 Terms and definitions The following terms and definitions apply to this document. 3.1 A non-commercial combustion machine that uses biogas as fuel, supports the cooking vessel with its own bracket, and directly heats the cooking vessel with the flame of the biogas combustion appliance. Note. For household biogas stoves, they are referred to as stoves below. 3.2 Embedded biogas stove embeddedbiogasstove A biogas stove embedded in the cooking table. Note. For embedded biogas stoves, they are referred to as embedded stoves below. 3.3 Standard conditions The dry biogas state is specified at a temperature of 15°C and an absolute pressure of 101.3 kPa. 3.4 Low calorific value Wobbe number netWobbenumber The ratio of the lower calorific value of biogas to the square root of its relative density. 3.5 Rated heat load nominalheatinput Rated heat flow The design value of the heat load of the stove marked by the manufacturer when using the test biogas under reference conditions at the rated biogas supply pressure. ......


GB/T 3606-2001 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 97.040 Y 68 Replacing GB/T 3606-1983 Domestic biogas stove ISSUED ON. NOVEMBER 12, 2001 IMPLEMENTED ON. MARCH 1, 2002 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the PRC Table of Contents Foreword . 3  1 Scope .. 4  2 Quoted standards . 4  3 Model and parameters . 4  4 Technical requirements . 5  5 Test methods .. 8  6 Sampling and inspection .. 15  7 Marking, packing, transport, and storage . 16  Domestic biogas stove 1 Scope This Standard specifies the technical requirements, test methods, inspection rules, and other contents of domestic biogas stoves. This Standard is applicable to the domestic biogas stove of which the standard rated heat flow of a single burner is not less than 2.33 kW (2000 kcal/h). 2 Quoted standards The provisions contained in the following standards, by reference in this Standard, constitute provisions of this Standard. At the time of publication of this Standard, the versions shown are valid. All standards will be revised. The parties which use this Standard shall explore the possibility of using the latest version of the following standards. GB/T 3768-1996 Acoustics - Determination of sound power levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane GB 16410-1996 Domestic gas appliances GB/T 16411-1996 Universal test methods of gas burning appliances for domestic use 3 Model and parameters 3.1 Model preparation 3.1.1 Domestic biogas stove is represented by Chinese pinyin JZZ. 3.1.2 The number of burners of the stove is represented by Arabic numerals. 3.1.3 The product’s remodeling number is represented by Chinese phonetic alphabets A, B, C, D.. 3.2 Model denotation At the rated pressure, IGNITE a fire hole in the burner. The flame spreads through all fire holes for no more than 4 s. 4.4.2 Combustion stability At the rated pressure, the burner flame is uniform, stable; free of tempering, lifted flame, and yellow flame. 4.4.3 Small fire performance At 4% of the rated pressure (30 Pa, 60 Pa), the burner flame shall not be tempered or extinguished. 4.5 Heat efficiency The heat efficiency at the rated heat flow shall be greater than 55%. 4.6 Concentration of carbon monoxide in exhaust smoke When working at the rated heat flow, the concentration of carbon monoxide in exhaust smoke does not exceed 0.05% [Excess air coefficient α=1,%(V/V)]. 4.7 Wind resistance In a windy state, the burner burns stably; and shall not be extinguished and tempered. 4.8 Ignition rate and performance of electric igniter 4.8.1 Fire ignites 8 times and more in 10 times. There shall be no 2 consecutive failures, and no deflagration. 4.8.2 When the battery voltage is 70% of the rated voltage, the ignition performance of the igniter is not affected. 4.9 Surface temperature The surface temperature of each part of biogas stove shall be less than the following values. a) Hand-touched parts during operation (knobs, etc.). room temperature of metal parts +25°C; room temperature of non-metal parts +35°C b) Surrounding parts of the parts which are not easy to touch by hand during operation. room temperature +105°C c) Dry battery case. room temperature +20°C 4.12.7 The outer surface and interior of the biogas stove shall be easy to clean and maintain. 4.13 Material and surface treatment 4.13.1 Material requirement a) The parts of domestic stove can be made of cast iron, steel, non-ferrous metals, or corrosion-resistant materials. The material requirements shall meet the current relevant national standards. b) The nozzle, nozzle holder, and liquid tray shall be made of metal materials of which the melting point is greater than 500°C. c) The burner and pot bracket shall be made of metal materials of which the melting point is greater than 700°C. d) The gas conduit shall be made of metal materials of which the melting point is greater than 350°C. e) The wall thickness of cast products shall not be less than 3 mm; and there shall be no obvious casting pores and other defects. The wall thickness of stainless steel products shall not be less than 0.3 mm. 4.13.2 Surface treatment The parts, which are made of cast iron and steel, shall be treated with electroplating, paint spraying, enamel, or other suitable anti-rust surfaces. 5 Test methods 5.1 Laboratory conditions The laboratory conditions shall comply with the provisions of GB/T 16411. 5.2 Test system The test system shall be equipped with a biogas container with a volume of no less than 5 m3; and shall be equipped with pressure regulating equipment. During the test, the pressure fluctuation shall be less than ±10 Pa. 5.3 Biogas for test It is stipulated that the lower heat value of artificial biogas for test is (21±1) MJ/m3 (standard volume). 5.4 Instruments for test 5.7.9 Electric igniter performance test 5.7.9.1 The igniter which uses dry battery shall regulate the supply voltage to 70% of rated voltage. 5.7.9.2 At the rated pressure, according to the following operating procedures, repeatedly IGNITE 10 times, DETECT the number of ignition. The operating procedure is to perform several preliminary ignitions in advance. The ignition operating mode and the ignition speed, according to the difference of igniters, are specified as follows. - The single-shot piezo igniter operates once at a time. Each time the speed is controlled within 0.5~1 s; - The rotary igniter rotates once at a time. Its rotational speed is 0.5~1 s; - When using direct-current power continuous discharge igniter, PLACE it on the “ignition” position for 2 s, it shall be considered as once. 5.7.10 Surface temperature test At 1.5 times the rated pressure, IGNITE the biogas stove; after burning for 30 min, for the stove surface, knob, gas piping joint, valve, and electric igniter housing and wire, TEST the surface temperature of all parts. 5.7.11 Noise test 5.7.11.1 Combustion noise. At 1.5 times the rated pressure, IGNITE the biogas stove; at 1 m away from the front of the stove, USE a common sound level meter to determine in Gear A. The ambient background noise shall be less than 40 dB; or be corrected according to Table 2 in GB/T 3768-1996. 5.7.11.2 Flameout noise. According to the above provisions, USE a sound level meter to carry out the test; READ the noise variation maximum. The noise maximum plus 5 dB is used as the test value. 5.7.12 Durability test 5.7.12.1 Plug valve of gas appliance USE the air of which the pressure is the same as the rated pressure of biogas; when the plug valve and the gas appliance are separated or the plug valve is installed on the gas appliance, at an operating speed of 5~20 times per minute, OPEN and CLOSE the valve; after 6000 tests, CARRY out airtightness test. 5.7.12.2 Electric igniter USE the biogas at the rated pressure or the air at the same pressure; when the electric igniter is installed on the igniter durability test equipment or the gas appliance, at an operating speed of 5~20 times per minute, after testing for 6000 times, CARRY out electric ignition performance test. 6 Sampling and inspection The biogas stove shall be subjected to exit-factory inspection and type inspection. 6.1 Exit-factory inspection 6.1.1 The items of exit-factory inspection are 4.1, 4.2, 4.4, and 7.1 of this Standard. 6.1.2 Only after the product passes the inspection by the quality inspection department of manufacturer and the certificate of qualification is filled out and issued, can it leave the factory. 6.2 Type inspection 6.2.1 In any of the following cases, it shall carry out type inspection. - Trial-manufacture type evaluation for interplant transfer production of new products or old products; - After formal production, if there are changes in structure and material and the product performance may be affected; - In normal production, when the cycle reaches one year; - After long-term production suspension of product, when the production resumes; - When there is a significant difference between the exit-factory inspection result and the last type inspection; - When the state quality supervision authority puts forward the requirement for type inspection. 6.2.2 The samples for type inspection are randomly selected in batches of products which have passed exit-factory inspection. 6.2.3 The distribution department, according to this Standard, carries out acceptance. ......