HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (18 Jan 2025)

GB/T 35925-2018 English PDF

GB/T 35925-2018_English: PDF (GB/T35925-2018)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 35925-2018English150 Add to Cart 0--9 seconds. Auto-delivery Determination of impurity fluorine ion in water soluble chemicals -- Ion chromatography method Valid GB/T 35925-2018


BASIC DATA
Standard ID GB/T 35925-2018 (GB/T35925-2018)
Description (Translated English) Determination of impurity fluorine ion in water soluble chemicals -- Ion chromatography method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G09
Classification of International Standard 71.040.40
Word Count Estimation 10,140
Date of Issue 2018-02-06
Date of Implementation 2018-09-01
Drafting Organization Qingdao Inspection and Quarantine Technology Development Center, Qingdao Institute of Product Quality Supervision and Inspection, Qingdao Sheng Han Chromatography Technology Co., Ltd., Qingdao Purren Instrument Co., Ltd., Qingdao Sunny Sunny Scientific Instrument Co., Ltd., Thermo Fisher Scientific (China) Limited Company, Hangzhou Special Equipment Inspection Institute
Administrative Organization National Chemical Standardization Technical Committee (SAC/TC 63)
Proposing organization China Petroleum and Chemical Industry Federation
Issuing agency(ies) People's Republic of China General Administration of Quality Supervision, Inspection and Quarantine, China National Standardization Administration


GB/T 35925-2018 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 G 09 Determination of Impurity Fluorine Ion in Water Soluble Chemicals – Ion Chromatography Method ISSUED ON. FEBRUARY 06, 2018 IMPLEMENTED ON. SEPTEMBER 01, 2018 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of PRC. Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative References ... 4 3 Principle ... 4 4 Reagents and Materials ... 5 5 Apparatus ... 5 6 Analytical Procedures ... 5 7 Result Calculation ... 7 8 Precision ... 7 Appendix A (Informative) Reference Chromatographic Conditions ... 8 Appendix B (Informative) Relevant Chromatograms of Determination of Impurity Fluoride ion in Water-Soluble Chemicals ... 9 Determination of Impurity Fluorine Ion in Water Soluble Chemicals – Ion Chromatography Method 1 Scope This Standard specifies the ion chromatographic method for the determination of impurity fluoride ion (F-) content in the water-soluble chemicals. This Standard is applicable to the determination of fluoride ion content in water-soluble chemicals with fluoride ion content ≤400mg/kg. In this Standard, the quantitative limit of organic chemicals is 0.02mg/kg; while the quantitative limit of inorganic chemicals is 4.0mg/kg. This Standard is not applicable to the insoluble chemicals and the chemicals with main component containing fluorine. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB/T 6682 Water for Laboratory Use – Specifications 3 Principle After treatment, the sample forms an aqueous solution; enters into the ion exchange chromatographic column with ion exchange resin as a stationary phase; the ion exchange resin is distributed by fixed charged group and free coordination ion; when eluted with a suitable eluent, the active exchange group on the ion exchange resin undergoes the ion exchange with ions in the test solution and ions in the eluent. As the eluent continues to flow, the anion in the test solution and the exchange group continue to occur exchanging – eluting – re-exchanging – re-eluting; depending on the different retention characteristics of the test anion on the chromatography column, the separation is realized; finally, the test anion is carried by the eluent to the detector and form a chromatographic peak. The group ion is qualitative by the retention time of each scale; perform ultrasound for 10min; stand for 60min; filter the supernatant by the filter membrane for testing. Organic chemicals. pipette 50mL of specimen into 100mL beaker; add 150µL of sodium hydroxide (4.2) to alkalinize; then evaporate to near dryness in water bath; dilute the slag with pure water; make constant volume into 10mL volumetric flask; perform ultrasound for 10min; stand for 60min; filter the supernatant by the filter membrane for testing. Alkali chemicals. accurately take 1.0g~3.0g (accurate to 0.001g) of specimen into 50mL beaker; dissolve into water; then transfer to 100mL volumetric flask; dilute to the scale; perform the ultrasound for 10min; stand for 60min; take the supernatant to pass the hydrogen-type cation exchange cartridge; collect the filtrate to filter by the filtered membrane for testing. 6.2 Ion chromatographic conditions a) Mobile phase. select according to the separation column, so that meet the requirements of separation in 5.5; meanwhile the main component can be eluted without disturbing the subsequent separation. For example, 20mmol/L sodium hydroxide solution (4.1). b) Flowrate. 1.0mL/min. c) Column temperature. 30°C. d) Sample injection volume. 25µL. e) Detector. conductivity detector. 6.3 Standard working curve Preparation of standard working solution. take 10mL of fluoride ion standard stock solution (4.3) into a 100mL volumetric flask; dilute with water to the scale; then prepare the 10µg/mL fluoride ion standard solution. Separately take 0.4mL, 0.8mL, 1.0mL, 2.0mL, 4.0mL, 5.0mL, 20.0mL, 50.0mL of fluoride ion standard solution into 100mL volumetric flasks; dilute with water to the scale; then prepare the standard working solution with fluoride ion concentration of 0.04µg/mL, 0.08µg/mL, 0.1µg/mL, 0.2µg/mL, 0.4µg/mL, 0.5µg/mL, 2.0µg/mL, 5.0µg/mL; such solution shall be prepared for current use. Take the above standard working solutions from the low to high concentrations into the ion chromatograph; draw a standard curve with ion concentration as abscissa and peak area as the ordinate. 6.4 Sample determination ......