Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34579-2017English170 Add to Cart 0--9 seconds. Auto-delivery Methods of measurement and limits for radiated disturbances from plasma display panel equipment in the frequency range 150 kHz to 30 MHz Valid GB/T 34579-2017
Standards related to: GB/T 34579-2017

BASIC DATA
Standard ID GB/T 34579-2017 (GB/T34579-2017)
Description (Translated English) Methods of measurement and limits for radiated disturbances from plasma display panel equipment in the frequency range 150 kHz to 30 MHz
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard M74
Classification of International Standard 33.100.10
Word Count Estimation 10,129
Date of Issue 2017-09-29
Date of Implementation 2018-04-01
Drafting Organization China Electronics Technology Group Corporation Institute of the third, Xiamen Guang Pu Electronics Co., Ltd.
Administrative Organization National Radio Interference Standardization Technical Committee (SAC/TC 79)
Proposing organization National Radio Interference Standardization Technical Committee (SAC / TC 79)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of PRC; China National Standardization Administration

GB/T 34579-2017 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 33.100.10 M 74 Methods of Measurement and Limits for Radiated Disturbances from Plasma Display Panel Equipment in the Frequency Range 150 kHz to 30 MHz (IEC/PAS 62825:2013, Methods of Measurement and Limits for Radiated Disturbances from Plasma Display Panel TVs in the Frequency Range 150 kHz to 30 MHz, MOD) ISSUED ON: SEPTEMBER 29, 2017 IMPLEMENTED ON: APRIL 1, 2018 Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Terms and Definitions ... 5  4 Limits ... 5  5 Measurement Requirements ... 6  6 Measurement Layout and Procedures ... 8  7 Standard Compliance ... 9  Bibliography ... 11  Foreword This Standard was drafted in accordance with the rules in GB/T 1.1-2009. This Standard adopts the re-drafting law in the modification and adoption of IEC/PAS 62825:2013 Methods of Measurement and Limits for Radiated Disturbances from Plasma Display Panel TVs in the Frequency Range 150 kHz to 30 MHz. In comparison with IEC/PAS 62825:2013, the technical differences and the causes for these differences are as follows: ---In terms of Normative References, this Standard adjusts the technical differences, so as to adapt to the technical conditions of our country. The adjustments are intensively reflected in Chapter 2 “Normative References”. See the specific adjustments below:  CISPR 32 is modified into reference without year number (see Chapter 1);  The reference of GB 3174 is added (see 5.5);  The reference of GB 4824-2013 is added (see Table 1). ---The scope of application is expanded from plasma TVs to plasma display panel equipment; ---The NOTE in Table 1 is modified into the main text; ---5.5 “EUT Working Status” is rewritten. This Standard was proposed by and shall be under the jurisdiction of National Technical Committee 79 on Radio Jamming of Standardization Administration of China (SAC/TC 79). The drafting organizations of this Standard: The 3rd Research Institute of China Electronics Technology Group Corporation; Xiamen GOPRO Guangpu Electronics Co., Ltd. The main drafters of this Standard: Xu Wei, Ding Shaohua, Chen Qingmei, Lin Jingping, Guo Song, Zhang Xiaogang. Methods of Measurement and Limits for Radiated Disturbances from Plasma Display Panel Equipment in the Frequency Range 150 kHz to 30 MHz 1 Scope This Standard specifies the methods of measurement and limits for radiated disturbances from plasma display panel equipment 150 kHz ~ 30 MHz. This Standard is applicable to plasma display panel equipment with a visible display area of 1 m or a larger diagonal intended for use in residential or commercial environments within the scope of GB/T 13837-2012 or CISPR 32. The corresponding frequency range of the radiofrequency radiated disturbances described in this Standard is 150 kHz ~ 30 MHz. This Standard specifies corresponding limits and measurement methods for the evaluation of radiofrequency radiated disturbances. The limit requirements specified in this Standard are the basic requirements of EMC. The requirements aim at avoiding affecting the radio reception in the 150 kHz ~ 30 MHz frequency range of the area when the display panel equipment are working. While adopting this Standard, other regulations on EMC radiated emission shall be implemented in accordance with GB/T 13837-2012 and CISPR 32. This Standard is a supplement to the requirements of other related standards on electromagnetic compatibility. The purposes of this Standard are as follows: a) Establish supplementary requirements to properly protect the frequency spectrum in the frequency range of 150 kHz ~ 30 MHz, so that the expected radio reception in this frequency range can be normally used; b) In order to ensure the reproducibility of measurement and the repeatability of measurement results, specific measurement procedures are specified. 2 Normative References The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB 3174 Characteristics of PAL-D Television Broadcasting System GB/T 4365 Electrotechnical Terminology - Electromagnetic Compatibility (GB/T 4365- 2003, IEC 60050 (161): 1990 + AMD 1: 1997, IDT) GB 4824-2013 Industrial, Scientific and Medical Equipment - Radio-frequency Disturbance Characteristics - Limits and Methods of Measurement (CISPR 11: 2010, IDT) GB/T 6113.101-2016 Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods of Measurement - Part 1-1: Radio Disturbance and Immunity Measuring Apparatus - Measuring Equipment (CISPR 16-1-1: 2010, IDT) GB/T 6113.104-2016 Radio Disturbance and Immunity Measuring Apparatus and Methods - Part 1-4: Radio Disturbance and Immunity Measuring Apparatus - Radiated Disturbance Measuring Antenna and Test Site (CISPR 16-1-4: 2010, IDT) GB/T 13837-2012 Sound and Television Broadcast Receivers and Associated Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement (IEC/CISPR 13:2009, MOD) CISPR 32 Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements 3 Terms and Definitions What is defined in GB/T 4365 and GB/T 13837-2012, and the following terms and definitions are applicable to this Standard. 3.1 Boundary of the EUT Boundary of the EUT refers to the smallest imaginary circle surrounding the equipment under test (including all connecting cables). 4 Limits 4.1 Overview The equipment specified in the scope of this Standard shall be measured at a standardized radiation test site. Open fields or semi-anechoic chambers are preferred (although these sites are verified in the frequency range of 30 MHz ~ 1 GHz in accordance with GB/T 6113.104-2016). The measuring equipment and methods of measurement are specified in Chapter 5 6 Measurement Layout and Procedures 6.1 Measurement Layout The EUT shall be placed on a non-metallic test bench that is 80 cm above the grounding plane. The distance between the center of the loop antenna and the boundary of the equipment under test shall be 3 m, as it is shown in Figure 1. When the EUT is equipped with a dedicated grounding terminal, use the shortest possible grounding wire to ground this grounding terminal. When the EUT is not equipped with a dedicated grounding terminal, it shall be tested under normal conditions of connection, for example, grounding through a power line or a coaxial signal line. 6.2 Measurement Procedures In the axial and parallel directions of the two antennas, respectively measure the radiated emission. The loop of the antenna defines a plane, and a horizontal line shall simultaneously pass through the center line of the antenna and the EUT. When the line connecting the horizontal line and the EUT is in the plane of the antenna loop, the antenna direction at this moment is defined as the parallel direction. When the line connecting the horizontal line and the EUT is perpendicular to the plane of the antenna loop, the antenna direction at this moment is defined as the axial direction. The two antenna directions are shown in Figure 2. For the EUT placed on the rotary table, the rotary table shall thoroughly rotate, and the measurement shall be conducted in the above-mentioned two antenna directions. In addition, record the highest electromagnetic radiated disturbance level of each frequency. For the EUT not placed on the rotary table, the loop antenna shall be placed in at least 4 orthogonal positions 3 m away from the EUT; each position shall be measured in the above-mentioned two antenna directions. 6.3 Expression of Measurement Results All results obtained from the radiated disturbance measurement shall be recorded in the test report. If the results in the frequency range being measured are not recorded in a continuous mode and / or in the form of a chart, then, the results shall at least include the following content. When the radiated emission margin is less than 10 dB, at least the 6 highest disturbance field strengths, disturbance frequencies, antenna polarization directions (axial or parallel) and rotary table angles shall be recorded. ...