HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (11 Jan 2025)

GB/T 34436-2023 English PDF (GB/T 34436-2017)

GB/T 34436-2023_English: PDF (GB/T34436-2023)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34436-2023English170 Add to Cart 0--9 seconds. Auto-delivery Determination of formamide in toy materials -- High performance liquid chromatography-mass spectrometry Valid GB/T 34436-2023
GB/T 34436-2017English399 Add to Cart 3 days [Need to translate] Determination of formamide in toy materials -- Gas chromatography-mass spectrometry (GC-MS) Obsolete GB/T 34436-2017


BASIC DATA
Standard ID GB/T 34436-2023 (GB/T34436-2023)
Description (Translated English) Determination of formamide in toy materials -- High performance liquid chromatography-mass spectrometry
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y57
Classification of International Standard 97.200.50
Word Count Estimation 9,983
Date of Issue 2023-03-17
Date of Implementation 2023-10-01
Older Standard (superseded by this standard) GB/T 34436-2017
Drafting Organization Shenzhen Institute of Metrology and Quality Inspection, Yike Testing and Certification Co., Ltd., Baoju (China) Children's Products Co., Ltd., Shantou Quality Supervision and Inspection Institute of Guangdong Province, Jiaxing Xiaohuzi Vehicle Industry Co., Ltd., Beijing Zhongqinglian Certification Center Co., Ltd. company
Administrative Organization National Toy Standardization Technical Committee (SAC/TC 253)
Issuing agency(ies) China National Light Industry Council

BASIC DATA
Standard ID GB/T 34436-2017 (GB/T34436-2017)
Description (Translated English) Determination of formamide in toy materials -- Gas chromatography-mass spectrometry (GC-MS)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y57
Classification of International Standard 97.200.50
Word Count Estimation 10,147
Date of Issue 2017-10-14
Date of Implementation 2018-05-01
Drafting Organization Shenzhen Institute of Metrology and Quality Inspection, Bureau Veritas US Product Testing (Shanghai) Co., Ltd., Goodbaby Children Products Co., Ltd., Jiangsu Yike Detection Technology Service Co., Ltd., Inspection and Quarantine Technology Center of Guangdong Entry-Exit Inspection and Quarantine Bureau Toys Baby Products Laboratory, Shanghai Institute of Quality Supervision, Inspection and the Shenzhen Entry-Exit Inspection and Quarantine Bureau Toy Testing Technology Center, Weikai Testing Technology Co., Ltd., Jiangsu Exit Inspection and Quarantine Light Industry Products and Children Products Testing Center, Fujian Province Product Quality Inspection Research Institute, China Import and Export Toys Testing Center in Shanghai, Zhejiang Province Quality Inspection Institute of Science and Technology, Beijing Light Alliance Certification Center
Administrative Organization National Toy Standardization Technical Committee (SAC/TC 253)
Proposing organization China National Light Industry Council
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of PRC; China National Standardization Administration


GB/T 34436-2023 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 97.200.50 CCS Y 57 Replacing GB/T 34436-2017 Determination of formamide in toy materials - High performance liquid chromatography-mass spectrometry ISSUED ON: MARCH 17, 2023 IMPLEMENTED ON: OCTOBER 1, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the PRC. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 5 4 Principle ... 5 5 Reagents or materials ... 6 6 Apparatus ... 6 7 Sample preparation ... 6 8 Sample extraction ... 7 9 Determination ... 7 10 Result calculation ... 7 11 Method limit of quantitation ... 8 12 Precision ... 8 13 Test report ... 8 Appendix A (Informative) Reference working conditions of high performance liquid chromatograph-mass spectrometer for the determination of formamide ... 10 Appendix B (Informative) Precision test results... 12 Determination of formamide in toy materials - High performance liquid chromatography-mass spectrometry IMPORTANT NOTE: The use of this document may involve certain hazardous materials, procedures and equipment; but not all safety issues related thereto are recommended. It is the user's responsibility to, before applying this document, establish appropriate safety and protection measures AND determine the applicability of relevant regulatory limitations. 1 Scope This document describes a method for the determination of formamide in toy materials using high performance liquid chromatograph-mass spectrometer. This document is applicable to the determination of formamide in foam materials such as ethylene-vinyl acetate copolymer (EVA), polyethylene (PE), chemically cross-linked polyethylene (XPE), and polyvinyl chloride (PVC) in toy products. It is used as a reference for the determination of formamide in other foam materials. 2 Normative references The contents of the following documents, through normative references in this text, constitute indispensable provisions of this document. Among them, for dated references, only the edition corresponding to that date applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 6682 Water for analytical laboratory use - Specification and test methods 3 Terms and definitions There are no terms and definitions that need to be defined in this document. 4 Principle Use water to ultrasonically extract the prepared samples. After filtering the extract, use high performance liquid chromatograph-mass spectrometer to determine; use external standard method to quantify. 8 Sample extraction Weigh two specimens of about 0.1 g (accurate to 0.1 mg) into the glass sample vial (6.4); accurately add 10 mL of water (5.1) and seal. After fully infiltrating the specimen, place it in an ultrasonic generator (6.2) for ultrasonic extraction for 3.5 h; cool to room temperature; use an organic microporous membrane (6.6) to filter it; wait for the determination. 9 Determination 9.1 Reference working conditions for high performance liquid chromatograph- mass spectrometer Since the setting of working conditions depends on the instrument used, the set parameters shall ensure the effective separation of formamide chromatographic peaks. Appendix A gives the reference working conditions of high performance liquid chromatograph-mass spectrometer for the determination of formamide. 9.2 Qualitative analysis According to the above analysis conditions (9.1), analyze the standard working solution (5.6) and the sample extract; use the retention time of characteristic ions and chromatographic peaks (see Figure A.1 in Appendix A) for qualitative analysis. If the selected ion proton number/charge number (m/z) is 46.0, the retention time of the detected chromatographic peak is consistent with that of the standard solution; it can be considered that the sample contains the target component. 9.3 Quantitative analysis Use the external standard method for quantitative analysis. Use the mass concentration of the standard working solution as the abscissa; use the quantitative ion peak area of the compound as the ordinate; draw the standard working curve; obtain the regression equation of the standard curve, to calculate the formamide content in the sample. If the specimen response value exceeds the linear range, it is necessary to dilute the specimen by an appropriate multiple AND re-inject the specimen for analysis. 9.4 Blank test Except that no specimen is added, follow the above operation steps. 10 Result calculation According to the formula (1), calculate the content of formamide in the specimen. Where: w - The content of formamide in the specimen, in milligrams per kilogram (mg/kg); c - The mass concentration of formamide in the sample solution, in milligrams per liter (mg/L); c0 - The mass concentration of formamide in the blank test, in milligrams per liter (mg/L); V - The volume of the extract, in milliliters (mL); D - The dilution factor of the extract; m - The mass of specimen weighed, in grams (g). The calculation result retains 3 significant figures. 11 Method limit of quantitation When the sampling size is 0.1 g and the extraction solution volume is 10 mL, the quantitation limit of this method is 10.0 mg/kg. 12 Precision In the same laboratory, using the same equipment by the same operator, according to the same test method, within a short period of time, by independently testing the same measured object; the absolute difference between the two independent test results obtained is not greater than 10% of the arithmetic mean of the two measured values; provided that no more than 5% of the cases are greater than 10% of the arithmetic mean of these two measured values. See Appendix B for the precision test data of the method in this document. 13 Test report The test report shall at least provide the following content: a) Specimen description; b) Number of this document; ......


GB/T 34436-2017 Determination of formamide in toy materials - Gas chromatography-mass spectrometry (GC-MS) ICS 97.200.50 Y57 National Standards of People's Republic of China Determination of formamide in toy materials Gas chromatography - mass spectrometry spectrometry (GC-MS) 2017-10-14 Published 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Foreword This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the China Light Industry Federation. This standard by the National Toy Standardization Technical Committee (SAC/TC253) centralized. This standard was drafted unit Shenzhen Institute of Metrology and Quality Inspection, Bureau Veritas US Commodity Inspection (Shanghai) Co., Ltd., good children for children Co., Ltd., Jiangsu billion Branch Detection Technology Services Ltd., Guangdong CIQ Inspection and Quarantine Technology Center toys baby products Laboratory, Shanghai Institute of Quality Supervision, Inspection and Quarantine, Shenzhen CIQ Toy Testing Technology Center, Wei Kai testing technology Limited, Exit Inspection and Quarantine of Jiangsu Light Industry Products and Children's Products Testing Center, Fujian Province Product Quality Inspection Institute, Shanghai, China Import and Export Toys Testing Center, Zhejiang Province Quality Inspection Institute of Science and Technology, Beijing Light Alliance Certification Center. The main drafters of this standard. Zhao Yan, Zhang Yao, Ke Dengming, Hu Aisheng, ants Le Chau, Sun Duoshi, Dong Fu silver, Xia Qingyun, Cheng Yulong, Chen Wei, Yu Wenjia, Liao Shangfu, Xu Dongyu. Determination of formamide in toy materials Gas chromatography - mass spectrometry 1 Scope This standard specifies the use of gas chromatography - mass spectrometry toys toys products ethylene - vinyl acetate (EVA) materials, formyl Amine detection methods. This standard applies to toys EVA material in the determination of formamide. 2 principle The prepared sample was extracted with a certain volume of methanol by ultrasound and the solution was filtered and determined by gas chromatography-mass spectrometry (GC-MS) Ding, external standard method. 3 Reagents and materials Unless otherwise specified, only reagents identified as analytically pure are used in the analysis. 3.1 Formamide (CAS No. 75-12-7) standard substance mass fraction of not less than 99%. 3.2 methanol. Chromatographic purity and above. 4 instruments and equipment 4.1 Gas Chromatography-Mass Spectrometry (GC-MS) with Electron Impact Source (EI). 4.2 ultrasonic generator. Temperature accuracy of ± 5 ℃. 4.3 electronic balance. Accuracy 0.1mg. 4.4 Reagent bottle, equipped with a sealing cap, of suitable volume, such as a 20 mL headspace bottle. 4.5 organic phase filter membrane pore size 0.45μm. 5 Sample Preparation Mechanical methods to obtain samples of EVA material from the toy samples, select the representative area of the sample, the sample is cut to no more than 5mm × 5mm × 5mm size particles. 6 sample Weigh about 0.25g sample, accurate to 1mg. Quickly loaded into the reaction flask (4.4), accurately add 10mL of methanol (3.2), sealed The sample is fully infiltrated and placed in an ultrasonic generator (4.2) for ultrasonic extraction. The temperature of the ultrasonic bath is maintained at (55 ± 5) ° C during the extraction process, Total extraction time 3.5h; water bath liquid level should not be less than the reaction bottle liquid level. The reaction flask out every 0.5h, shaking, shake. In the room The extract was filtered through a filter membrane (4.5) to a chromatographic flask under the temperature to be tested. Note formaxamine samples (≥1000mg/kg) may be appropriate to reduce the sample size and increase the volume of the extraction solution. ......

Similar standards: GB/T 34430.4-2024  GB/T 34430.5-2024  
Similar PDFs (Auto-delivered in 9 seconds): GB/T 34436-2023  GB/T 34371-2017  GB/T 34370.9-2020  GB/T 34370.8-2020