Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169760 (Oct 24, 2020)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB/T 33728-2017

Chinese Standard: 'GB/T 33728-2017'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB/T 33728-2017English70 Add to Cart 0--10 minutes. Auto immediate delivery. Textiles -- Evaluation for electrostatic properties -- Method of static decay Valid GB/T 33728-2017
GB/T 33728-2017Chinese14 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID GB/T 33728-2017 (GB/T33728-2017)
Description (Translated English) Textiles -- Evaluation for electrostatic properties -- Method of static decay
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard W04
Classification of International Standard 59.080.30
Word Count Estimation 6,615
Date of Issue 2017-05-12
Date of Implementation 2017-12-01
Quoted Standard GB/T 8629-2001
Drafting Organization Shanghai Bai Jie electrostatic detection technology center, the spinning standard (Beijing) Inspection and Certification Center Co., Ltd., Shanghai morning Long static Technology Co., Ltd., Shandong Ruyi Technology Group Co., Ltd., Ningbo Textile Instrument Factory
Administrative Organization National Textile Standardization Technical Committee (SAC/TC 209)
Proposing organization China Textile Industry Federation
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, China National Standardization Administration Committee
Summary This standard specifies the test method and evaluation of the static decay time of textiles. This standard applies to all kinds of textile fabrics. Other film materials can be used.

GB/T 33728-2017
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 59.080.30
W 04
Textiles – Evaluation for Electrostatic
Properties – Method of Static Decay
纺织品 静电性能的评定 静电衰减法
ISSUED ON. MAY 12, 2017
IMPLEMENTED ON. DECEMBER 1, 2017
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine;
Standardization Administration of PRC.
How to BUY & immediately GET a full-copy of this standard?
2. Search --> Add to Cart --> Checkout (3-steps);
3. No action is required - Full-copy of this standard will be automatically &
immediately delivered to your EMAIL address in 0~60 minutes.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative References ... 4
3 Terms and Definitions ... 4
4 Principle ... 4
5 Apparatus ... 5
6 Test Conditions ... 6
7 Specimen Preparation ... 6
8 Test Procedures ... 6
9 Result Expression ... 7
10 Evaluation ... 7
11 Test Report ... 7
Foreword
This Standard was drafted as per the rules specified in GB/T 1.1-2009.
This Standard was proposed by China National Textile and Apparel Council.
This Standard shall be under the jurisdiction of National Technical Committee for
Standardization of Textiles (SAC/TC 209).
Drafting organizations of this Standard. Shanghai Hi-Clean Static Test Technology
Center, CTTC (Beijing) Inspection & Certification Center Co., Ltd., Shanghai Chenlong
Static Technology Co., Ltd. Shandong RUYI Technology Group Co., Ltd., and Ningbo
Textile Equipment Factory.
Chief drafting staffs of this Standard. Ren Shengxin, Han Yuru, Huang Jianhua, Xu
Ming, Wang Baojun, Wei Xiaobo, Huang Wei, Yang Jingwen, Du Yuanshu, Zhao Hui,
Hu Junwei, and Zhu Yafen.
Textiles – Evaluation for Electrostatic
Properties – Method of Static Decay
1 Scope
This Standard specifies the test method and evaluation of static decay time of textiles.
This Standard is applicable to various types of textiles. Other membrane materials can
be used for reference.
2 Normative References
The following documents are essential to the application of this document. For the
dated documents, only the versions with the dates indicated are applicable to this
document; for the undated documents, only the latest version (including all the
amendments) are applicable to this document.
GB/T 8629-2001 Textiles – Domestic Washing and Drying Procedures for Textile
Testing
3 Terms and Definitions
The following terms and definitions are applicable to this document.
3.1 Static decay time
The time required for the voltage of charged sample to decay to the given percentage
of its starting value.
4 Principle
After the sample is charged to 5000V, turn off the power; the voltage on the sample is
attenuated by earthing, then determine the time required by its voltage decaying to
500V.

GB/T 33728-2017
Textiles - Evaluation for electrostatic properties - Method of static decay
ICS 59.080.30
W04
National Standards of People's Republic of China
Evaluation of electrostatic properties of textiles - Electrostatic attenuation method
2017-05-12 released
2017-12-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Preface
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by China Textile Industry Federation.
This standard is under the jurisdiction of the National Textile Standardization Technical Committee (SAC/TC209).
The standard drafting unit. Shanghai Bai Jie electrostatic detection technology center, the spinning standard (Beijing) Inspection and Certification Center Co., Ltd., Shanghai morning
Electric Technology Co., Ltd., Shandong Ruyi Technology Group Co., Ltd., Ningbo Textile Instrument Factory.
The main drafters of this standard. Ren Shengxin, Han Yuru, Huang Jianhua, Xu Ming, Wang Baojun, Wei Xiaobo, Huang Wei, Yang Jingwen, Du Yuanxu, Zhao Hui,
Hu Junwei, Zhu Yafen.
Evaluation of electrostatic properties of textiles - Electrostatic attenuation method
1 Scope
This standard specifies the test method and evaluation of the static decay time of textiles.
This standard applies to all kinds of textile fabrics. Other film materials can be used.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
Household washing and drying procedures for textile testing GB/T 8629-2001
3 terms and definitions
The following terms and definitions apply to this document.
3.1
Static decay time staticdecaytime
The time required for the voltage on the charged sample to decay to a given percentage of its starting value.
4 principle
After the sample is charged to 5000V, the power is turned off and the voltage on the sample is attenuated by grounding to measure the voltage decay to 500V
time.
5 devices and instruments
Electrostatic Attenuation Tester consists of high-voltage generator, non-contact electrostatic field meter, timer, sample fixture, metal shield and display group
As shown in Figure 1.
The components of the static attenuation tester are as follows.
--- sample fixture, metal material, through the current. The distance between the ends of the specimen is (130 ± 5) mm. Used to fasten the sample, can
Keep the specimen in a horizontal suspension.
--- metal shield, can cover the fixture and sample as a whole, and with the fixture and any part of the sample distance of not less than 5mm.
--- non-contact electrostatic field meter, the probe and the test surface distance (25 ± 1) mm, the minimum voltage of ± 10V resolution, measurement
Not less than 5000V ~ -5000V, the accuracy of not less than 5%.
--- high voltage generator, can produce no less than 5000V positive and negative DC power supply.
--- timer, the minimum resolution of 0.01s, the record range of not less than 60s.
Description.
1 --- sample fixture;
2 --- metal shield;
3 --- non-contact electrostatic field meter probe;
4 --- sample;
5 --- high voltage generator;
6 --- timer, monitor.
Figure 1 Schematic diagram of electrostatic attenuation tester
In the test, measures shall be taken to ensure that the operator is not in danger under proper operation.
6 test conditions
A. the temperature is (23 ± 3) ℃, the relative humidity is (12 ± 3)%;
B. temperature is (20 ± 2) ℃, relative humidity is (35 ± 5)%;
C. temperature is (23 ± 3) ℃, relative humidity is (50 ± 5)%.
Other test environmental conditions should be indicated in the test report.
7 Sample preparation
If necessary, the sample is washed in accordance with 4A procedure in GB/T 8629-2001, and the sample is dried at 60 ° C for 1 hour,
Off the number of times approved for washing, drying.
Three samples were randomly sampled from the sample and the size of each sample was (70 ± 5) mm × (140 ± 5) mm. When the sample has latitude and longitude (straight cross
To the positive or negative characteristics of different, or can not determine the characteristics of the circumstances, the need for sampling, each group of three samples. The above samples should be selected
Set the test environment to stand at no less than 24h.
8 test procedures
8.1 The specimen shall be fastened to the fixture in the metal shield (see Fig. 1). The specimen shall be kept parallel to the probe and the area of the fixture shall not be exposed
At 2500mm2, and should deal with the sample power to zero potential, and then close the metal shield.
8.2 adjust the high-voltage generator, the sample voltage, the sample charged to 5000V, if the sample can not be powered to 5000V
Record the sample can not be powered up and stop the test.
8.3 Stops the power on the sample, starts the timer and grounds the sample, reads the sample voltage down to 500V and records, decays
Stop the test when the time is greater than 60s, the test results by> 60s record.
8.4 adjust the high-voltage generator, the sample voltage, so that the sample charged to -5000V charged, if the sample can not be powered to -5000V
The recording sample can not be energized and the test is stopped.
8.5 to stop the power of the sample, while starting the timer and the sample ground, read the sample voltage attenuation to -500V time and record,
Less than 60s time to stop the test, the test results by> 60s record.
8.6 Test the remaining samples according to the test procedure of 8.1 to 8.5.
9 results ex......