GB/T 32483.3-2016_English: PDF (GB/T32483.3-2016)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 32483.3-2016 | English | 254 |
Add to Cart
|
3 days [Need to translate]
|
Energy performance of lamp controlgear -- Part 3: Controlgear for halogen lamps and LED modules -- Method of measurement to determine the efficiency of the controlgear
| Valid |
GB/T 32483.3-2016
|
Standard ID | GB/T 32483.3-2016 (GB/T32483.3-2016) | Description (Translated English) | Energy performance of lamp controlgear -- Part 3: Controlgear for halogen lamps and LED modules -- Method of measurement to determine the efficiency of the controlgear | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K74 | Classification of International Standard | 29.140.99 | Word Count Estimation | 13,142 | Date of Issue | 2016-02-24 | Date of Implementation | 2016-09-01 | Quoted Standard | IEC 61047-2004; IEC 61347-1-2007; IEC 61347-1-2007/AMD 1-2010; IEC 61347-1-2007/AMD 2-2012; IEC 61347-2-2; IEC 61347-2-13; IEC 61558-1; IEC 61558-2-6; IEC GUIDE 115-2007 | Adopted Standard | IEC 62442-3-2014, IDT | Drafting Organization | Hangzhou heyday Technology Instrument Co., Ltd | Administrative Organization | National Lighting Standardization Technical Committee | Regulation (derived from) | National Standard Announcement No | Proposing organization | China Light Industry Association | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China, Standardization Administration of the People Republic of China | Summary | This standard specifies the method of measuring the power loss of the inductive transformer and the stand-by power loss of the electronic converter of the halogen lamp and the LED module. At the same time, a calculation method is provided for the efficiency of the control device of the halogen lamp and the LED module. This standard applies to electrical control devices consisting solely of control devices and lamps - lamp circuits. For multi-purpose power supply only consider the lighting part. This standard is applicable to the measurement of the total input power and standby power of all control devices for household and general commercial lighting, halogen lamps and LED modules, as well as for calculating the efficiency of control devices. This standard does not apply to: constitute the overall lamp control device; control circuit in the case of series capacitance; controllable wire wound inductive control device. |
GB/T 32483.3-2016
Energy performance of lamp controlgear. Part 3. Controlgear for halogen lamps and LED modules.Method of measurement to determine the efficiency of the controlgear
ICS 29.140.99
K74
National Standards of People's Republic of China
Lamp control device efficiency requirements
Part 3. halogen lamps and LED modules
Method for measuring the efficiency of control devices
Energyperformanceoflampcontrolgear-Part 3. Controlgearforhalogen
(IEC 62442-3..2014, IDT)
2016-02-24 released
2016-09-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface III
1 range 1
2 normative reference document 1
3 Terms and definitions 2
4 General requirements 3
4.1 Applicability 3
4.2 General precautions for testing 4
4.3 Controllable control device 4
4.4 Measurement Uncertainty 4
4.5 Sampling of the controlled control device 4
4.6 Number of samples 4
4.7 Power supply 4
4.8 Power supply voltage waveform 4
4.9 alternative load 5
4.10 Thermocouple Temperature Indicator 5
4.11 Instrument Accuracy 5
4.12 measuring circuit 5
4.13 multi-rated voltage control device 5
4.14 multi-power output control device 6
5 Halogen lamp and LED module control device (transformer, converter) the efficiency of the measurement and calculation method 6
5.1 Measuring device. input and output power 6
5.2 Inductive (transformer) and electronic (converter) control device efficiency calculation 6
5.3 Measuring device. Input power in off mode 7
5.4 Electronic control unit - Standby power measurement of the converter 7
Reference 9
Figure 1 Inductance control device (transformer) Power measurement settings and converters (electronic control device) Input and output power measuring device 6
Figure 2 Inductive control device (transformer) and converter (electronic control device) Input power measurement device 7
Figure 3 electronic control device - converter standby power measurement device 7
Table 1 Typical nominal power supply data for some areas 4
Preface
GB/T 32483 "Light control device efficiency requirements" plan to publish 3 parts.
- Part 1. Fluorescent lamp control device control device line total input power and control device efficiency measurement method;
- Part 2. Measurement methods for the efficiency of control devices for high intensity gas discharge lamp control devices (except fluorescent lamps);
Part 3. Methods for measuring the efficiency of control devices for halogen tungsten and LED modules.
This part is part 3 of GB/T 32483.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part uses the translation method equivalent to the use of IEC 62442-3..2014 "Lamp control device efficiency requirements Part 3. Halogen lamps and
LED module control device efficiency measurement method ".
In this part of the normative reference to the international documents have a consistent correspondence between the following documents.
Performance requirements for dc/AC electronic buck converters for tungsten filament GB/T 19654-2005 (IEC 61047..1991,
IDT)
Control devices for lamps - Part 1. General requirements and safety requirements (IEC 61347-1..2007,
IDT)
Control device for lamps - Part 3. Particulars for DC/AC electronic buck converters for tungsten filament lamps GB/T
(IEC 61347-2-2..2006, IDT)
Control devices for lamps - Part 14. Particulars for DC or AC electronic control devices for LED modules
Special requirements (IEC 61347-2-13..2006, IDT)
Safety of power transformers, power supplies, reactors and similar products - Part 1. General requirements and tests - GB 19212.1-2008.
(IEC 61558-1..2005, IDT)
--- GB 19212.7-2012 Transformers, reactors, power supply units and similar products with supply voltage of 1100V and below
Part 7. Particular requirements and tests for power isolators for safety isolating transformers and built-in safety isolating transformers
(IEC 61558-2-6..2009, IDT)
This part is made by the China Light Industry Federation.
This part of the National Lighting Standardization Technical Committee (SAC/TC224) centralized.
This part of the drafting unit. Hangzhou heyday Technology Instrument Co., Ltd., Hengdian Group was state Lighting Co., Ltd., Shenzhen Yu Fu lighting
Co., Ltd., Wenzhou City Quality and Technical Supervision and Inspection Institute, Hangzhou Hongyan Electric Co., Ltd., Hangzhou Anderson Electronics Co., Ltd., Zhejiang crystal day lighting
Technology Co., Ltd., Beijing Electric Light Source Research Institute.
The main drafters of this part. Hou Minxian, Nie Lixun, Huang Shanshi, Cao Xiaobing, Sun Quanming, Wu Zhaoming, Yu Jianming, Fu Chuangye, Duan Yanfang,
Zheng yanfeng
Lamp control device efficiency requirements
Part 3. halogen lamps and LED modules
Method for measuring the efficiency of control devices
1 Scope
This part of GB/T 32483 specifies the power loss of the inductive transformers of the halogen and LED modules and the standby of the electronic converter
Measurement of power loss.
At the same time, for the halogen lamp and LED module control device efficiency defines a calculation method.
This section applies to the electrical control unit - lamp line consisting only of the control unit and the lamp.
For the multi-purpose power supply only consider the part of the lighting.
Note. It is not included in the production process to test the requirements of individual control devices.
This section applies to the total input power and standby power of all control devices for home and general commercial lighting, halogen lamps and LED modules
The measurement method, and the calculation method of the control device efficiency.
This section does not apply to.
- a control device that constitutes a monolithic lamp;
--- control circuit in the case of series capacitance;
--- Controlled wire wound inductive control device.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
IEC 61047..2004 DC/AC electronic buck converter for tungsten filament performance requirements (DCorAC.suppliedelectronic
step-downconvertorsforfilamentlamps-Performancerequirements)
IEC 61347-1..2007 Lamp control devices - Part 1. General requirements and safety requirements (Lampcontrolgear - Part 1.
Generalandsafetyrequirements)
AMD1..2010
AMD2..2012
IEC 61347-2-2 Lamp controlgear - Part 2-2. Particular requirements for dc or AC powered electronic buck converters for tungsten filament lamps
(Lampcontrolgear-Part 2-2. Particularrequirementsford.c.ora.c.suppliedelectronicstep-downcon-
vertorsforfilamentlamps
IEC 61347-2-13 Lamp control devices - Part 2-13. Particular requirements for DC or AC electronic control devices for LED modules
(Lampcontrolgear-Part 2-13. Particularrequirementsford.c.ora.c.suppliedelectroniccontrolgear
forLEDmodules)
IEC 61558-1 Safety of power transformers, power supplies, reactors and similar products - Part 1. General requirements and tests
ofpowertransformers, powersupplies, reactorsandsimilarproducts-Part 1. Generalrequirements
andtests)
IEC 61558-2-6 Safety of transformers, reactors, power supply units and similar products with supply voltages of 1100V and below Section 2-6 of Safety
. Special requirements and tests for safety isolating transformers and power supply units with built-in safety isolating transformers (Safetyoftransformers, re-
......
|