GB/T 29024.3-2012English324 Add to Cart Days<=3 Determination of particle size distribution -- Single particle light interaction methods -- Part 3: Light extinction liquid-borne particle counter GB/T 29024.3-2012 Valid GB/T 29024.3-2012
GB/T 29024.3-2012Chinese20 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

   

BASIC DATA
Standard ID GB/T 29024.3-2012 (GB/T29024.3-2012)
Description (Translated English) Determination of particle size distribution. Single particle light interaction methods. Part 3; Light extinction liquid-borne particle counter
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard A28
Classification of International Standard 19.120
Word Count Estimation 19,154
Adopted Standard ISO 21501-3-2007, IDT
Drafting Organization Beijing Physical and Chemical Analysis and Testing Center
Administrative Organization National particle characterization and sorting and screen Standardization Technical Committee
Regulation (derived from) National Standards Bulletin No. 41 of 2012
Proposing organization National Technical Committee for Characterization and Screening of Particles and Screening Standardization (SAC/TC 168)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method of liquid photoresist particle counter (LELPC) calibration and verification method, the instrument used to measure particles suspended in a liquid particle size and particle number concentration. This section describes a

GB/T 29024.3-2012
.. Determination of particle size distribution Single particle light interaction methods Part 3; Light extinction liquid-borne particle counter
ICS 19.120
A28
National Standards of People's Republic of China
Single particle size analysis of optical measurement methods
Part 3. Liquid Particle Counter resist method
methods-Part 3. Lightextinctionliquid-borneparticlecounter
(ISO 21501-3.2007, IDT)
Issued on. 2012-12-31
2013-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Terms and definitions 1
3 2 Requirements
3.1 Calibration particle size 2
Verify setpoint diameter 3.2 2
3.3 Counting Accuracy 2
Particle size 3.4 Resolution 2
3.5 The maximum number of particle concentration 2
3.6 sampling flow 2
3.7 The sampling time
3.8 Sampling Volume 2
3.9 Calibration cycle 2
3.10 Test Report 2
4 Test Method 3
4.1 Calibration particle size 3
Verify setpoint diameter 4.2 5
4.3 Counting Accuracy 5
Particle size 4.4 Resolution 5
4.5 The maximum number of particle concentration 6
4.6 sampling flow 6
4.7 Sampling time 6
4.8 Sampling Volume 7
4.9 Calibration 7
Appendix A (informative) particle size calibration uncertainty assessment 8
Annex B (informative) particle size resolution 10
Authentication method Annex C (informative) particle size and particle size calibration set value 11
Annex D (informative) Calibration diameter Resolution 13
References 14
Foreword
GB/T 29024 "single particle size analysis of optical measurement method" is divided into the following four parts.
--- Part 1. Light scattering aerosol spectrometer;
--- Part 2. Light scattering liquid particle counter;
--- Part 3. Liquid Particle Counter resist method;
--- Part 4. clean room light scattering dust particle counter.
This section is GB/T Part of 329,024.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 21501-3.2007 "Optical measurement of single particle size analysis - Part 3. Liquid
Particle counter resist Law "(in English).
For ease of use, this section made the following editorial changes.
--- Increase the informative Appendix C "particle size diameter of calibration and verification methods set value";
--- Increase the informative Appendix D "calibrated particle size resolution."
This part of the characterization and sorting by the National Standardization Technical Committee and mesh particles (SAC/TC168) and focal points.
This section is responsible for drafting. Beijing Physical and Chemical Analysis and Testing Center, the machine Productivity Promotion Center, China Institute of Metrology.
Participated in the drafting of this section. Powder Technology Association Beijing, Tianjin New Technology Industrial Park Tianhe Medical Instrument Co., Ltd., Tianjin days
Big Sky Technology Co., Ltd., AVIC Beijing Great Wall Institute of Measurement and Testing Technology, Merck Chemicals (Shanghai) Co., Ltd.
Drafters of this section. Zhou Suhong, Wang Qifeng, Liu Junjie, Zhang Ge, Yu Fang, Zhang Tao, Zhang Lingfei, Fu Yan, Song Dandan Liu Yanjun, the official Chi-kin,
Zhao.
introduction
Many areas require monitoring of particulate pollution, such as. electronic industry, pharmaceutical industry, precision instrument manufacturing, and medical fields. Particles count
The number of particles in the liquid is monitoring contaminants effective equipment. Currently, the law resist liquid particle counter particle size and particle size calibration setpoint
Authentication method, particle size resolution calibration general have three methods, in addition to the body of the method 1, the present section in Annex C, Appendix D
It lists the other two methods. This section is intended to provide a particle counter calibration procedures and test methods to reduce the measurement error of the same instrument
Difference and the difference between different instruments to measure results.
Single particle size analysis of optical measurement methods
Part 3. Liquid Particle Counter resist method
1 Scope
This section GB/T 29024 specifies the method photoresist liquid particle counter (LELPC) calibration and verification methods, the instrument used to measure
The amount of particles suspended in a liquid particle size and particle number concentration. Resist method described in this section based on the measurement of single particles, measured by the method
Given the typical size range is 1μm ~ 100μm.
The instrument can be used to evaluate drugs (such as. injection, water for injection, intravenous injection) cleanliness, can also be used to measure various liquids
The number of particle concentration and particle size distribution.
This section includes the following aspects.
--- Particle size calibration;
--- Verify particle size setpoint;
--- Counting accuracy;
--- Particle size resolution;
--- The maximum particle number concentration;
--- Sample flow;
--- Sampling time;
--- Sample volume;
--- Calibration cycle;
---testing report.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1
Standard particles calibrationparticles
Traceable to international or national average particle size of the length standard known monodisperse spherical particles. Standard uncertainty of the average particle diameter should be
Within ± 2.5%.
2.2
Counting accuracy countingefficiency
The determination of the same sample, the ratio of the value of the standard method of resist liquid particle counter (LELPC) test values \u200b\u200bwith the standard material.
2.3
Particle Counter particlecounter
By light scattering particle measurement method or resist the number and size of equipment.
2.4
Pulse height analyzer pulseheightanalyser; PHA
Analytical Instruments pulse height distribution.
Related standard: GB/T 29024.4-2017    GB/T 29024.2-2016