HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (18 Jan 2025)

GB/T 16632-2019 English PDF (GB/T 16632-2008, GB/T 16632-1996)

GB/T 16632-2019_English: PDF (GB/T16632-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 16632-2019English100 Add to Cart 0--9 seconds. Auto-delivery Determination of scale inhibition performance of water treatment chemicals -- Calcium carbonate precipitation method Valid GB/T 16632-2019
GB/T 16632-2008English90 Add to Cart 0--9 seconds. Auto-delivery Determination of scale inhibition performance of water treatment agents -- Calcium carbonate precipitation method Obsolete GB/T 16632-2008
GB/T 16632-1996English239 Add to Cart 2 days [Need to translate] The determination of scale inhibition performance of water treatment agents--Calcium carbonate precipitation method Obsolete GB/T 16632-1996


BASIC DATA
Standard ID GB/T 16632-2019 (GB/T16632-2019)
Description (Translated English) Determination of scale inhibition performance of water treatment chemicals -- Calcium carbonate precipitation method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G76
Classification of International Standard 71.040.40
Word Count Estimation 6,630
Date of Issue 2019-08-30
Date of Implementation 2020-07-01
Drafting Organization Henan Qingshuiyuan Technology Co., Ltd., Guangzhou Special Pressure Equipment Testing and Research Institute, Hangzhou Special Equipment Testing Research Institute, Nanjing Yushui Technology Co., Ltd., Shenzhen Zhunuo Testing Co., Ltd., Shandong Taihe Water Treatment Technology Co., Ltd., Jiangsu Province Special Equipment Safety Supervision and Inspection Institute Suzhou Branch, CNOOC Tianjin Chemical Research and Design Institute Co., Ltd., Jiashan Lvye Environmental Protection Material Factory, Hangzhou Mingzhu Water Treatment Technology Co., Ltd., Tianjin Zhengda Technology Co., Ltd.
Administrative Organization National Chemical Standardization Technical Committee (SAC/TC 63)
Proposing organization China Petroleum and Chemical Industry Federation
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

BASIC DATA
Standard ID GB/T 16632-2008 (GB/T16632-2008)
Description (Translated English) Determination of scale inhibition performance of water treatment agents - Calcium carbonate precipitation method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G76
Classification of International Standard 71.040.40
Word Count Estimation 8,837
Date of Issue 2008-04-01
Date of Implementation 2008-09-01
Older Standard (superseded by this standard) GB/T 16632-1996
Quoted Standard GB/T 601; GB/T 603; GB/T 6682
Drafting Organization Jiyuan Qingyuan Industrial Co., Ltd.
Administrative Organization Chemical treatment agent branch nationwide Standardization Technical Committee
Regulation (derived from) National Standard Approval Announcement 2008 No.5 (Total No.118)
Proposing organization China Petroleum and Chemical Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the method for the determination of similar treatment inhibits the precipitation of calcium carbon- scale performance. Namely calcium carbonate deposition. This standard applies to similar treatment inhibits precipitation of carbonate scale performance assessment.

BASIC DATA
Standard ID GB/T 16632-1996 (GB/T16632-1996)
Description (Translated English) The determination of scale inhibition performance of water treatment agents--Calcium carbonate precipitation method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G76
Classification of International Standard 71.100.80
Word Count Estimation 6,623
Date of Issue 1996/12/2
Date of Implementation 1997/5/1
Quoted Standard GB/T 601-1988; GB/T 603-1988; GB/T 6682-1992,
Regulation (derived from) Announcement of Newly Approved National Standards No. 5, 2008 (No. 118 overall)
Proposing organization Ministry of Chemical Industry of the People Republic of China
Issuing agency(ies) State Bureau of Technical Supervision


GB/T 16632-2019 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 G 76 Replacing GB/T 16632-2008 Determination of scale inhibition performance of water treatment chemicals - Calcium carbonate precipitation method ISSUED ON: AUGUST 30, 2019 IMPLEMENTED ON: JULY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Method summary ... 4  4 Reagents or materials ... 5  5 Instruments and apparatuses ... 7  6 Test water ... 7  7 Preparation of sample solution ... 7  8 Test procedure ... 8  9 Result calculation ... 8  10 Allowable difference ... 8  Determination of scale inhibition performance of water treatment chemicals - Calcium carbonate precipitation method 1 Scope This Standard specifies the determination of scale inhibition performance of water treatment chemicals to inhibit calcium carbonate precipitation -- calcium carbonate precipitation method. This Standard applies to the evaluation of the scale inhibition performance of water treatment chemicals to inhibit calcium carbonate precipitation under the same conditions in the circulating cooling water system; it also applies to the screening of the water treatment chemicals to inhibit calcium carbonate scale formulation. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 601, Chemical reagent - Preparations of reference titration solutions GB/T 603, Chemical reagent - Preparations of reagent solutions for use in test methods GB/T 6682, Water for analytical laboratory use - Specification and test methods 3 Method summary Use water for actual working conditions, or prepared water that contains a certain amount of bicarbonate radical and calcium ions AND water treatment chemicals to prepare into the test solution. Under heating conditions, promote the accelerated decomposition of calcium bicarbonate into calcium carbonate. After reaching the equilibrium, determine the calcium ion concentration in the test solution. The larger the calcium ion concentration, the better the scale inhibition performance of the water treatment chemicals. V -- the value of the volume of the taken sodium bicarbonate standard solution, in milliliters (mL) (V = 5). 4.5 Calcium chloride standard solution: 1 mL contains about 6.0 mg of Ca2+; prepare and calibrate according to the following steps: a) Preparation: weigh 16.7 g of anhydrous calcium chloride into a 100 mL beaker; use water to dissolve it; transfer all to a 1 000 mL volumetric flask; use water to dilute to the mark; shake well. b) Calibration: pipette 2.00 mL of calcium chloride standard solution into a 250 mL conical flask; add about 80 mL of water, 5 mL of potassium hydroxide solution and about 0.1 g of calcium-carboxylic acid indicator; use Ethylene Diamine Tetraacetic Acid standard titration solution to titrate until the solution turns from purple-red to bright blue as the end point. c) Calculation: calculate the content of calcium ion (Ca2+) by mass concentration ρ2, according to Formula (2): Where: ρ2 -- the mass concentration of calcium ion (Ca2+), in milligrams per milliliter (mg/mL); V1 -- the value of the volume of Ethylene Diamine Tetraacetic Acid standard titration solution that is consumed in the titration, in milliliters (mL); c -- the exact value of the actual concentration of Ethylene Diamine Tetraacetic Acid standard titration solution, in moles per liter (mol/L); M -- the value of the molar mass of calcium ion (Ca2+), in grams per mole (g/mol) (M = 40.08); V -- the value of the volume of the taken calcium chloride standard solution, in milliliters (mL) (V = 2). 4.6 Hydrochloric acid standard titration solution: c(HCl) is about 0.1 mol/L. 4.7 Ethylene Diamine Tetraacetic Acid standard titration solution: c (EDTA) is about 0.01 mol/L. 4.8 Bromocresol green-methyl red indicator solution 4.9 Calcium-carboxylic acid indicator: weigh 0.2 g of calcium-carboxylic acid indicator [2-hydroxy-1(2-hydroxy-4-sulfo-1-naphthalenazo)-3-naphthoic acid] ......


GB 16632-2008 GB ICS 71.040.40 G 76 National Standard of the People’s Republic of China Replacing GB 16632-1996 Determination of scale inhibition performance of water treatment agents - Calcium carbonate precipitation method ISSUED ON. APRIL, 2008 IMPLEMENTED ON. SEPTEMBER 1, 2008 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China; Standardization Administration of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative References ... 4  3 Method Summary ... 4  4 Reagents & Materials ... 5  5 Instrument & Apparatus ... 7  6  Preparation of Sample Solution ... 7  7  Analysis Steps ... 7  8  Calculation of Analysis Results ... 8  9  Allowable Difference ... 8  Foreword This Standard replaces GB/T 16632-1996 “Determination of scale inhibition performance of water treatment agents - Calcium carbonate precipitation method”. Compared with GB/T 16632-1996, there is no technical difference. This Standard was proposed by China Petroleum and Chemical Industry Association. This Standard shall be under the jurisdiction of Water Treatment Agent Branch of National Chemistry Standardization Technical Committee (SAC/TC 63/SC 5). The drafting organizations of this Standard. Qingyuan Jiyuan Industrial Co., Ltd., Tianjin Chemical Research & Design Institute, and Shandong Taihe Water Treatment Co., Ltd. Main drafters of this Standard. Wang Zhiqing, Zhu Chuanjun, Sun Baoji, Li Lin, and Bai Ying. This Standard was issued in 1996 for the first time. Determination of scale inhibition performance of water treatment agents - Calcium carbonate precipitation method 1 Scope This Standard specifies the determination method of scale inhibition performance that similar water treatment agents inhibit the separation of calcium carbonate, i.e., calcium carbonate precipitation method. This Standard is applicable to the assessment of scale inhibition performance that similar water treatment agents inhibit the separation of calcium carbonate. 2 Normative References The following standards contain the provisions which, through reference in this Standard, constitute the provisions of this Standard. For dated references, subsequent amendments (excluding corrections) or revisions do not apply to this Standard. However, the parties who enter into agreement based on this Standard are encouraged to investigate whether the latest versions of these documents are applicable. For undated reference documents, the latest versions apply to this Standard. GB/T 601 Chemical Reagent - Preparations of Standard Volumetric Solutions GB/T 603 Chemical Reagent – Preparations of Reagent Solution for Use in Test (GB/T 603-2002, ISO 6353-1.1982, NEQ) GB/T 6682 Water for analytical laboratory use - Specification and test methods (GB/T 6682-1992, neq ISO 3696.1987) 3 Method Summary Use the prepared water that contains certain amount of calcium bicarbonate and calcium ion AND water treatment agent to prepare the test solution. Under heating conditions, it accelerates the calcium bicarbonate to decompose to calcium carbonate. After equilibrium is reached, determine the calcium ion’s per liter (mol/L); V - the calcium chloride standard solution taken, in milliliter (mL); M - the molar mass of calcium (Ca2+), in grams per mole (g/mol) (M=40.08). 4.9 Water treatment agent sample solution. 1.00 mL contains about 0.500 mg of water treatment agent (calculated by dry basis). 5 Instrument & Apparatus 5.1 Thermostatic water bath. the temperature shall be controlled at (80±1)°C. 5.2 Conical flask. 500 mL, equipped with stopper of Φ5 mm~Φ10 mm, glass tube of 300 mm long. 6 Preparation of Sample Solution 6.1 Preparation of test solution Add 250 mL of water into 500 mL flask; use buret to add a certain volume of standard solution of calcium chloride, so as to make the amount of calcium ions to be 120 mg. Use suction pipette to add 5.0 mL of water treatment agent sample solution; shake evenly. Then add 20 mL of borax buffer solution; shake evenly. Use buret to slowly add a certain volume of standard solution of sodium bicarbonate (shake while adding), so as to make the amount of bicarbonate ions to be 366 mg; use water to dilute to scale; shake evenly. 6.2 Preparation of blank test solution In another 500 mL flask, except that the sample solution is not added with water treatment agent, follow Step 6.1 to operate. 7 Analysis Steps Respectively place the test solution and the blank test solution in two clean conical flasks; dip these two flasks into thermostatic water bath of (80±1) °C (the test solution shall not exceed the level of the liquid in the water bath); place in constant temperature for 10 h. After it is cooled to room temperature, use medium speed quantitative filter paper to dry filter. Respectively pipette 25.00 mL of filtrate; place in 250 mL conical flasks; add water to 80 mL; add 5 mL of potassium hydroxide solution and about 0.1 g of calcium - carboxylic acid indicator. Use edetate disodium standard solution to titrate the solution till the end point - it turns from purplish red to bright blue. Use equation (2) to ......

Similar standards: GB/T 14420-2024  GB/T 43664.1-2024  
Similar PDFs (Auto-delivered in 9 seconds): GB/T 16632-2019  GB/T 15453-2018  GB/T 14637-2021  GB/T 14636-2021