GB/T 15453-1995 English PDF (GB/T 15453-2018 Newer Version)

GB/T 15453-1995 (GB/T15453-1995, GBT 15453-1995, GBT15453-1995)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15453-2018English170 Add to Cart 0--9 seconds. Auto-delivery Determination of chloride in water for industrial circulating cooling system and boiler Valid GB/T 15453-2018
GB/T 15453-2008English279 Add to Cart 3 days [Need to translate] Water for industrial circulating cooling system and boiler -- Determination of chloride Obsolete GB/T 15453-2008
GB/T 15453-1995English199 Add to Cart 2 days [Need to translate] Industrial circulating cooling water Determination of chloride Silver nitrate titration method Obsolete GB/T 15453-1995
Preview PDF: GB/T 15453-2018    Standards related to: GB/T 15453-1995

BASIC DATA
Standard ID GB/T 15453-1995 (GB/T15453-1995)
Description (Translated English) Industrial circulating cooling water Determination of chloride Silver nitrate titration method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G76
Classification of International Standard 13.06
Word Count Estimation 5,593
Date of Issue 1995/1/12
Date of Implementation 1995/10/1
Older Standard (superseded by this standard) HG 5-1505-1985
Adopted Standard ISO 9297, NEQ
Proposing organization Ministry of Chemical Industry of the People Republic of China
Issuing agency(ies) State Bureau of Technical Supervision


GB/T 15453-2018 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.40 G 76 Replacing GB/T 15453-2008 Determination of chloride in water for industrial circulating cooling system and boiler ISSUED ON: JUNE 07, 2018 IMPLEMENTED ON: JANUARY 01, 2019 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 General ... 4 4 Molar method ... 5 5 Potentiometric titration method ... 6 6 Coprecipitation enrichment spectrophotometry method ... 8 Annex A (informative) Preparation of silver nitrate standard titration solution ... 11 Determination of chloride in water for industrial circulating cooling system and boiler 1 Scope This Standard specifies the method to determine chloride content in water for industrial circulating cooling system and boiler. The molar method and potentiometric titration method in this Standard are applicable to the determination of chloride content in natural water, circulating cooling water, softened water and boiler water. The determination range of molar method is 3mg/L~150mg/L. When it exceeds 150mg/L, the sampling volume can be appropriately reduced. Determine after dilution. The determination range of potentiometric titration method is 5mg/L~1000mg/L. Coprecipitation and enrichment spectrophotometry method is suitable for the determination of chloride in demineralized water and boiler feed water. The determination range is 10μg/L~100μg/L. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 601, Chemical reagent - Preparations of standard volumetric solutions GB/T 602, Chemical reagent - Preparations of stock standard solutions GB/T 603, Chemical reagent - Preparations of reagent solutions for use in test methods GB/T 6682, Water for analytical laboratory use - Specification and test methods 3 General WARNING -- The strong acids used in this Standard are corrosive. Avoid inhalation or contact with skin during use. If splashed on the human body, rinse immediately with plenty of water. In severe cases, seek medical attention immediately. The reagents and water used in this Standard, unless otherwise specified, shall be analytically pure reagents and grade three water that meets the requirements of GB/T 6682. The standard titration solution, impurity standard solution, preparation and product required in the test shall be prepared in accordance with the provisions of GB/T 601, GB/T 602 and GB/T 603, unless other requirements are specified. 4 Molar method 4.1 Principle Use potassium chromate as indicator. In the pH range of 5.0~9.5, use silver nitrate standard titration solution to titrate. Silver nitrate reacts with chloride to form silver chloride white precipitate. When there is excess silver nitrate, it reacts with potassium chromate indicator to form brick red silver chromate precipitation. It indicates that the reaction has reached the end point. The reaction formulas are: 4.2 Reagents or materials 4.2.1 Nitric acid solution: 1+300. 4.2.2 Sulfuric acid solution: c(1/2H2SO4) is about 0.1mol/L. 4.2.3 Silver nitrate standard titration solution: c(AgNO3) is about 0.02mol/L. Prepare according to GB/T 601. It can also be prepared according to Annex A. 4.2.4 Potassium chromate indicator solution: 50g/L. 4.2.5 Phenolphthalein indicator solution: 10g/L ethanol solution. 4.3 Test steps Use a pipette to measure 50mL or 100mL of water sample into a 250mL conical flask. Add two drops of phenolphthalein indicator solution. If the water sample turns red, use nitric acid solution or sulfuric acid solution to adjust the pH of the water sample. Make the red just colorless. Add 1.0mL of potassium chromate indicator solution. Under the condition of white background, use silver nitrate standard titration solution to titrate until the brick red color just appears. Conduct the blank test at the same time. 4.4 Result calculation (White) (Brick red) titration solution to titrate till the potential jump point appears. The chloride ion content can be calculated from the volume of the silver nitrate standard titration solution consumed by the jump point. 5.2 Reagents or materials 5.2.1 Nitric acid solution: 1+300. 5.2.2 Sulfuric acid solution: c(1/2H2SO4) is about 0.1mol/L. 5.2.3 Silver nitrate standard titration solution: c(AgNO3) is about 0.05mol/L. 5.2.4 Methyl orange indicator solution: 1g/L. 5.3 Instruments and equipment 5.3.1 Automatic potentiometric titrator: Equipped with silver/silver chloride reference electrode, silver electrode or composite silver electrode. 5.3.2 Stirrer. 5.4 Test steps Use a pipette to take an appropriate volume of water sample into a measuring cup. For water samples with pH >7 or water samples containing antiscalants, adjust the pH of the water sample to 3~4 (it may add two drops of methyl orange indicator solution. Use nitric solution or sulfuric solution to adjust the pH of water sample. Make the solution turn from yellow to orange-red). Place the measuring cup on the titration stand. Insert the electrodes. Switch on the potentiometric titrator and stirrer. Use silver nitrate standard titration solution to titrate. Stop titration when a complete jump curve appears. 5.5 Result calculation The chloride content is calculated in mass concentration ρ2. The value is expressed in milligrams per liter (mg/L), calculated according to formula (2): Where, V1 - The value of the volume of the standard titration solution of silver nitrate consumed when the specimen is titrated to the potential jump point, in milliliters (mL); c - The exact value of the actual concentration of the silver nitrate standard titration solution, in moles per liter (mol/L); M - The value of the molar mass of chlorine, in grams per mole (g/mol) (M = 35.45); 6.2.6 Ferric nitrate-perchloric acid solution: Weigh 12.0g of ferric nitrate [Fe(NO3)3·9H2O]. Use 43mL of perchloric acid and appropriate amount of water to dissolve. Then use water to dilute to 1000mL. 6.2.7 Chloride standard stock solution: 0.1mg/mL. 6.2.8 Chloride standard solution: 10μg/mL. Pipette 10mL of chloride standard stock solution to a 100mL volumetric flask. Use water to dilute to the scale. 6.3 Instruments and equipment 6.3.1 Spectrophotometer: Equipped with a 30mm absorption cell. 6.3.2 Centrifuge: The rotating speed can reach 5000r/min. It is equipped with a 250mL polyethylene centrifuge tube. 6.3.3 All glassware, polyethylene centrifuge tubes, sampling bottles shall be immersed in nitric acid solution. Rinse with water before use. 6.4 Test steps 6.4.1 Plotting of calibration curve 6.4.1.1 Use a pipette to respectively measure 0.00mL (blank), 0.20mL, 0.40mL, 0.60mL, 1.00mL, 1.50mL, and 2.00mL of chloride standard solution. Pour into 250mL polyethylene centrifuge tubes. Use water to dilute to about 200mL. The corresponding chloride ion masses are 0.0μg, 2.0μg, 4.0μg, 6.0μg, 10.0μg, 15.0μg and 20.0μg, respectively. 6.4.1.2 Add 4mL of lead nitrate solution to the centrifuge tube. Shake well. Add 4mL of disodium hydrogen phosphate-potassium dihydrogen phosphate mixed solution. Shake well. Let stand for 5min. 6.4.1.3 Place the centrifuge tube in the centrifuge tube holder. Centrifuge at 5000r/min for 5min. Pour off the centrifuge. Leave the precipitate in the centrifuge tube. Add 10.00mL of ferric nitrate-perchloric acid solution to the centrifuge tube. Make the precipitate dissolved completely. 6.4.1.4 Add 1.00mL of mercury thiocyanate-methanol solution. After 5min of color development, use a 30mm absorption cell at a wavelength of 460nm. Use blank as a reference. Measure its absorbance. 6.4.1.5 Take the measured absorbance as the ordinate and the corresponding chloride ion mass as the abscissa to plot a calibration curve or calculate a regression equation. 6.4.2 Determination of water sample Use a pipette to measure 200mL of water sample. Place in a 250mL polyethylene ......