HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 11604-2015 English PDF

US$449.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 11604-2015: Testing procedure of radio interference generated by high voltage equipment
Status: Valid

GB/T 11604: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 11604-2015English449 Add to Cart 4 days [Need to translate] Testing procedure of radio interference generated by high voltage equipment Valid GB/T 11604-2015
GB/T 11604-1989English239 Add to Cart 3 days [Need to translate] Test methods for measuring radio interference from high voltage equipment Obsolete GB/T 11604-1989

PDF similar to GB/T 11604-2015


Standard similar to GB/T 11604-2015

GB/T 19212.5   GB/T 10228   GB/T 25095   GB/T 16896.3   GB/T 16896.1   

Basic data

Standard ID GB/T 11604-2015 (GB/T11604-2015)
Description (Translated English) Testing procedure of radio interference generated by high voltage equipment
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K40
Classification of International Standard 19.080
Word Count Estimation 21,253
Date of Issue 2015-09-11
Date of Implementation 2016-04-01
Older Standard (superseded by this standard) GB/T 11604-1989
Quoted Standard GB 311.1-2012; GB/T 2900.19-1994; GB/T 4365-2003; GB/T 6113.101; GB/T 16927.1; CISPR 16-1-2
Adopted Standard IEC/TR CISPR 18-2-2010, MOD
Regulation (derived from) National Standard Announcement 2015 No.25
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the high-voltage electrical equipment radio interference testing methods. This Standard applies in the laboratory of AC and DC high voltage electrical equipment (including attachments) radio interference testing apparatus comprising: high voltage switchgear, transformers, voltage divider, coupling capacitors, surge arresters, bushings, insulators and the like. This Standard specifies the test methods are applicable to type tests, routine tests, sampling tests and performance tests. This Standard test method is limited to measuring the test circuit conductive portion of the test radio interference regulations, which do not involve interference radiating portion.

GB/T 11604-2015: Testing procedure of radio interference generated by high voltage equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(High-voltage electrical equipment Radio interference test method) ICS 19.080 K40 National Standards of People's Republic of China Replacing GB/T 11604-1989 High voltage electrical equipment radio interference test method (IEC /T RCISPR18-2.2010, MOD) Issued on. 2015-09-11 2016-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Test Conditions 2 4.1 General principles 2 4.2 test state 2 4.3 pairs of claim 2 test area 4.4 atmospheric conditions 2 4.5 Test Frequency 3 4.6 Measuring Instruments 3 Radio interference 5 AC electrical test equipment 3 5.1 AC radio interference test principle 3 5.2 Test circuit and physical layout 4 5.3 Test circuit element 6 5.4 measuring instrument is connected to receive 6 5.5 validation checking test circuit 7 5.6 calibration test circuit 7 Determining the level of radio interference 5.7 8 5.8 Additional monitoring during the test 9 Radio interference 5.9 AC electrical equipment testing procedures 9 Information given in test report 10 5.10 6 DC radio interference testing of electrical equipment 10 6.1 DC electrical equipment testing requirements for radio interference 10 Radio interference 6.2 DC Electrical equipment test loop 10 Radio interference 6.3 DC Electrical equipment testing procedures 11 Appendix A (informative) standard CISPR quasi-peak measuring instrument receives a response to AC corona noise 13 Annex B (informative) differs from the basic standard instrument CISPR radio interference measuring apparatus 15 Phenomenon Appendix C (informative) Description 16 DC radio interference References 17

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 11604-1989 "high-voltage electrical equipment radio interference testing methods." This standard and GB/T 11604- Compared to 1989, in addition to editorial changes outside the main technical changes are as follows. --- Radio interference voltage increases, the term describes the rated voltage; --- Chapter reprogramming, and the techniques and the experimental loop have clearly described in more detail; --- State of the sample gives a clear definition of description (see 4.2); --- Test area gives specific requirements (see 4.3); --- On the atmospheric conditions of temperature, pressure and humidity range be revised, given the high altitude of the altitude correction requirements (see 4.4); --- The reference test frequency recommended values \u200b\u200bgiven in our laboratory 1MHz (see 4.5); --- Increased content measuring instruments (see 4.6); --- Radio interference AC electrical test equipment in the circuit layout, installation and test validation checking arrangement, loop, loop calibrator, Additional monitoring period and so give a detailed description (see Chapter 5); --- Increasing the DC electrical equipment radio interference test content (see Chapter 6); --- Increase A "standard CISPR quasi-peak measuring instrument for receiving AC corona noise response" Appendix informative; --- Increase the informative Appendix B "differs from the basic standard instrument CISPR radio interference measuring apparatus"; --- Increase the informative appendix C "DC radio interference phenomenon described." This standard uses the redrafted law revision using IEC /T RCISPR18-2.2010 Radio interference "of overhead lines and high-voltage equipment Characteristics - Part 2. Measurement methods and procedures to determine the limits. " The Standard and IEC /T RCISPR18-2.2010 and technical differences The following reasons. --- Reference of this standard IEC /T RCISPR18-2. Section 20104.5 "radio interference measuring laboratory of high voltage equipment" content Modify other sections not involved; --- Radio interference voltage increases, the term describes the rated voltage; --- On the atmospheric conditions of temperature, pressure and humidity range be revised, given the high altitude of the altitude correction requirements (see 4.4); --- The reference test frequency recommended values \u200b\u200bgiven in our laboratory 1MHz (see 4.5); --- Increasing the DC electrical equipment radio interference test content (see Chapter 6). Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. The standard proposed by China Electrical Equipment Industrial Association. This standard by the national high voltage test and insulation technology with Standardization Technical Committee (SAC/TC163). This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute, the national high-voltage electrical quality monitoring Governor Inspection Center, the National Insulator arrester Quality Supervision and Inspection Center, Kunming Electric Apparatus Research Institute, the National Quality Supervision, Inspection Transformer Heart, high-voltage electrical machinery industry product quality inspection center (Shenyang), Tsinghua University, Xi'an Jiaotong University, Xi'an Electric Power System Co. Division, Xi'an high-voltage electrical stock company, Xi'an Electric Transformer Co., Ltd., Xi'an Electric arrester Co., Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd. Henan high level of electrical, Guilin Power Capacitor Co., Ltd., Shaanxi Power Academy of Sciences, Hubei Electric Power Research Institute, Electric Power Research Institute of Jiangxi Province, Guangdong Electric Power Design Institute, China Southern Power Grid Technology Research Research Centre, Siemens (China) Co., Ltd. Shanghai Branch. The main drafters of this standard. Choi Dong, Wang Jiansheng, Wu Xiong, Li Yanming, Li Ni, Wei Peng, Zhang Xiaoyong, Chen Nan, Hao Yuliang, Xiao-Xuan, Sunhao Liang, Wang Ting, Qi Qingcheng, Liao Li, Zhao Lei, Zhou Qiongfang, Yan Jinghui, Wang Jun, Lv Xiangpeng, what strategy, Zhang Shu, Zhengyu Hong, Zhao Ying, Zhang Jianxin, Guan Xing Yan, Tsang Wu, Zuo Qiang Lin Guoqiang, Deng Wanting, Jiang Tao, Cheng positive Caoxiang Lin, Liu Lei, Gu Long River. This standard replaces the standards previously issued as follows. --- GB/T 11604-1989. High voltage electrical equipment radio interference test method

1 Scope

This standard specifies the high-voltage electrical equipment radio interference testing methods. This standard applies in the laboratory of AC and DC high voltage electrical equipment (including attachments) radio interference test, the device comprising. a high pressure Switchgear, transformers, voltage divider, coupling capacitors, surge arresters, bushings, insulators and the like. This standard specifies the test methods are applicable to type tests, routine tests, sampling tests and performance tests. The standard test method is limited to measuring the test circuit conductive portion of the test radio interference regulations, which do not involve radiation section Interference.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 311.1-2012 insulation coordination - Part 1. Definitions, principles and rules (IEC 60071-1.2006, MOD) GB/T 2900.19-1994 Electrotechnical term high voltage test technique and insulation coordination (neqIEC 60071-1.1993) GB/T 4365-2003 Electrotechnical terminology Electromagnetic Compatibility (idt IEC 60050 (161) 1990) GB/T 6113.101 radio disturbance and immunity measuring apparatus and methods - Part 1-1. Radio disturbance and anti- Interference measuring equipment measuring equipment (GB/T 6113.101-2008, CISPR16-1-1.2006, IDT) GB/T 16927.1 High-voltage test techniques - Part 1. General definitions and test requirements (GB/T 16927.1-2011, IEC 60060-1.2010, MOD) CISPR16-1-2 radio disturbance and immunity measuring apparatus and method - Part 1-2. Radio disturbance and immunity measuring Instrument auxiliary equipment conducting interference (Specificationforradiodisturbanceandimmunitymeasuringapparatusand methods-Part 1-2. Radiodisturbanceandimmunitymeasuringapparatus-Ancilaryequipment- Conducteddisturbances)

3 Terms and Definitions

GB/T 4365-2003 and defined the following terms and definitions apply to this document. 3.1 Radio interference (high voltage electrical equipment) radiointerference (ofhighvoltageequipment) Under normal operation of electrical equipment having a radio frequency voltage generated by the electromagnetic interference components. Note. This standard is a direct measurement device radio interference pulse current through an electrical circuit coupling loops, and radio interference voltage to represent radio The level of interference. Radio interference voltage in units of μV, can also be expressed in decibels, at this time, 1μV to 0dB. 3.2 AC electrical equipment the maximum voltage highestvoltageforalternatingcurrentequipment Um Valid values \u200b\u200baccording to equipment insulation and other features associated equipment standards associated design phase maximum voltage. In normal Under operating conditions by the relevant provisions of the Technical Committee, the voltage can be continuously applied to the device.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 11604-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 11604-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 11604-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 11604-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 11604-2015?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11604-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information