HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (11 Jan 2025)

GB/T 11446.4-2013 English PDF (GB/T 11446.4-1997, GB 11446.4-1989)

GB/T 11446.4-2013_English: PDF (GB/T11446.4-2013)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 11446.4-2013English160 Add to Cart 0--9 seconds. Auto-delivery Test method for resistivity of electronic grade water Valid GB/T 11446.4-2013
GB/T 11446.4-1997English199 Add to Cart 2 days [Need to translate] Test methods for resistivity of electronic grade water Obsolete GB/T 11446.4-1997
GB 11446.4-1989English199 Add to Cart 2 days [Need to translate] Test method for resistivity of electronic grade water Obsolete GB 11446.4-1989


BASIC DATA
Standard ID GB/T 11446.4-2013 (GB/T11446.4-2013)
Description (Translated English) Test method for resistivity of electronic grade water
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L90
Classification of International Standard 31.030
Word Count Estimation 8,819
Older Standard (superseded by this standard) GB/T 11446.4-1997
Quoted Standard GB/T 11446.1-2013; GB/T 11446.3-2013
Drafting Organization MII materials for Quality Supervision and Inspection Center
Administrative Organization China Electronics Standardization Institute
Regulation (derived from) National Standards Bulletin 2013 No. 27
Proposing organization Ministry of Industry and Information Technology of the People's Republic of China
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies test methods of electronic grade water resistivity. This standard applies to electronic grade water resistance test.

BASIC DATA
Standard ID GB/T 11446.4-1997 (GB/T11446.4-1997)
Description (Translated English) Test methods for resistivity of electronic grade water
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L90
Classification of International Standard 31.03
Word Count Estimation 5,543
Date of Issue 1997/9/1
Date of Implementation 1998/9/1
Older Standard (superseded by this standard) GB 11446.4-1989
Drafting Organization Institute of Semiconductors, Chinese Academy of Sciences, Institute of Standardization, Ministry of Electronics Industry
Administrative Organization Institute of Standardization, Ministry of Electronics Industry
Proposing organization People Republic of China Ministry of Electronics Industry
Issuing agency(ies) State Bureau of Technical Supervision
Summary This standard specifies test methods of electronic grade water resistivity. This standard applies to test resistance was (0. 5 ~ 18) M�� �� cm (25 ��) of electronic grade water.

BASIC DATA
Standard ID GB 11446.4-1989 (GB11446.4-1989)
Description (Translated English) Test method for resistivity of electronic grade water
Sector / Industry National Standard
Classification of Chinese Standard L90
Word Count Estimation 5,573
Date of Issue 1989/6/22
Date of Implementation 1990/3/1


GB/T 11446.4-2013 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 31-030 L 90 Replacing GB/T 11446.4-1997 Test method for resistivity of electronic grade water ISSUED ON: DECEMBER 31, 2013 IMPLEMENTED ON: AUGUST 15, 2014 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 5  4 Measuring principle ... 6  5 Disturbing factors ... 6  6 Reagents ... 6  7 Measuring instruments ... 7  8 Measurement procedures ... 7  9 Report ... 9  Appendix A (Normative) Temperature correction curve of resistivity ... 10  Appendix B (Normative) Concentration and conductivity of potassium chloride conductivity standard solution ... 11  Test method for resistivity of electronic grade water 1 Scope This Part of GB/T 11446 specifies the test method for the electrical resistivity of electronic grade water. This Part applies to the testing of resistivity of electronic grade water. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard. GB/T 11446.1-2013 Electronic grade water GB/T 11446.3-2013 Generic rules for test methods of electronic grade water 3 Terms and definitions The terms and definitions as defined in GB/T 11446.3-2013, as well as the following terms and definitions, apply to this document. 3.1 Electrical conductivity The conductivity is the reciprocal of the resistivity, which is represented by the symbol δ, in the unit of Siemens per centimeter (S/cm). The theoretical conductivity of pure water is 0.05482 µS/cm (25 °C). 3.2 Cell constant The ratio of the effective distance (L) between the two electrode plates TO the space's cross-sectional area (A), in unit of per centimeter (cm-1). The EW-I electronic grade water, which is specified in GB/T 11446.1-2013. The water, which is used to prepare the potassium chloride conductivity standard solution, shall be exposed to the laboratory atmosphere, to achieve equilibrium. 6.2 Potassium chloride standard solution Bake the solid conductivity standard potassium chloride (standard substance BW 0401) at 110 °C, for 2 h, before use. Then put it in a desiccator, to cool to room temperature, before use. When preparing the solution, the ambient temperature shall be 20 °C ± 2 °C. See Appendix B, for the relationship between potassium chloride standard solution and conductivity. 7 Measuring instruments 7.1 Conductivity meter For the instrument used in this method, the AC signal, that passes through the conductivity cell, during measurement, shall be an AC signal; its frequency can be in the range of 25 Hz ~ 100 Hz. 7.2 Conductivity cell The cell constant of the conductivity cell is generally 0.01 cm-1 ~ 0.1 cm-1. According to the conductivity range of the specimen, select a conductivity cell, which has a suitable cell constant, for measurement. See Appendix B, for the selection of the cell constant. 7.3 Thermometer The measuring range of the thermometer shall be 0 °C ~ 35 °C, which has an accuracy of 0.1 °C. 7.4 Constant temperature water bath 25 °C ± 0.1 °C constant temperature water bath. 8 Measurement procedures 8.1 Determination of the cell constant Use the electronic grade water, that is exposed to the laboratory air, where the air reaches an equilibrium with the carbon dioxide in the air, to thoroughly clean the conductivity cell. Then use the corresponding potassium chloride standard solution, to rinse it 3 times. Then fully fill conductivity cell, with the standard solution (the standard solution used shall be as close as possible to the conductivity of the measured water). Put it in a constant temperature bath. ......

Similar standards: GB/T 11446.10-2013  GB/T 11446.1-2013  GB/T 11446.3-2013  
Similar PDFs (Auto-delivered in 9 seconds): GB/T 11446.4-2013  GB/T 11446.3-2013  GB/T 11446.5-2013  GB/T 11446.6-2013