GB 7260.1-2008 English PDF

GB 7260.1-2008_English: PDF (GB7260.1-2008)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 7260.1-2008English155 Add to Cart 0--9 seconds. Auto-delivery [GB/T 7260.1-2008] Uninterruptible power systems (UPS) -- Part 1-1: General and safety requirements for UPS used in operator access areas Valid GB 7260.1-2008
GB/T 7260.1-2023English1194 Add to Cart 8 days [Need to translate] Uninterruptible power systems (UPS) -- Part 1: Safety requirements Valid GB/T 7260.1-2023
Newer version: GB 7260.1-2023    Standards related to: GB 7260.1-2023

BASIC DATA
Standard ID GB 7260.1-2008 (GB7260.1-2008)
Description (Translated English) [GB/T 7260.1-2008] Uninterruptible power systems(UPS). Part 1-1: General and safety requirements for UPS used in operator access areas
Sector / Industry National Standard
Classification of Chinese Standard K85
Classification of International Standard 29.200
Word Count Estimation 33,325
Date of Issue 2008-05-20
Date of Implementation 2009-04-01
Adopted Standard IEC 62040-1-1-2002, MOD
Drafting Organization Emerson Network Power Co., Ltd.
Administrative Organization National Standardization Technical Committee of Power Electronics
Regulation (derived from) Announcement of Newly Approved National Standards No. 8, 2008 (No. 121 overall)
Proposing organization China Electrical Equipment Industry Association
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Chinese standard relates to DC link energy storage device having an electronic uninterruptible power supplies. This standard refers to GB 4943-2001 and IEC 60950-1: 2001 related content. This standard includes an uninterruptible power supply (UPS) primary function is to ensure the continuity of AC power supply output. UPS also allows power to maintain the specified characteristics, thereby improving power quality. GB 4943-2001 and IEC 60950-1: 2001 relevant chapters on regional differences comments also apply. This standard applies to pre- installed in the operator access area, low-voltage distribution systems for mobile, stationary, fixed or embedded -mounted UPS.

GB/T 7260.1-2008 (GB 7260.1-2008) GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 29.200 K 85 GB/T 7260.1-2008 Uninterruptible power systems (UPS) – Part 1-1. General and safety requirements for UPS used in operator access areas (IEC 62040-1-1.2002, MOD) ISSUED ON. MAY 20, 2008 IMPLEMENTED ON. APRIL 01, 2009 Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope and specific applications ... 5 2 Normative references ... 6 3 Definitions ... 7 4 General conditions for tests ... 12 5 Fundamental design requirements ... 19 6 Wiring, connections and supply ... 27 7 Physical requirements ... 28 8 Electrical requirements and simulated abnormal conditions ... 33 9 Connection to telecommunication networks ... 35 Annex A (normative) Test for resistance to heat and fire ... 36 Annex B (normative) Motor tests under abnormal conditions ... 36 Annex C (normative) Transformers ... 36 Annex D (normative) Measuring instruments for touch-current tests ... 36 Annex E (normative) Temperature rise of a winding ... 36 Annex F (normative) Measurements of clearances and creepage distances . 37 Annex G (normative) Alternative method for determining minimum clearances. ... 37 Annex J (informative) Table of electrochemical potentials ... 37 Annex K (normative) Thermal controls ... 37 Annex H (informative) Guidance on protection against ingress of water and foreign objects ... 38 Annex L (normative) Backfeed protection test ... 40 Annex M (normative) Examples of reference load conditions ... 42 Annex N (normative) Ventilation of battery compartments ... 47 Annex X (informative) Guidance for disconnection of batteries during shipment ... 51 Foreword All technical contents of this Part are mandatory. GB 7260 “Uninterruptible power systems (UPS)” consists of the following parts. - Part 1-1. General and safety requirements for UPS used in operator access areas; - Part 1-2. General and safety requirements for UPS used in restricted access locations; - Part 2. Electromagnetic compatibility (EMC) requirements; - Part 3. Method of specifying the performance and test requirements. This Part of is Part 1-1 of GB 7260. This Part modifies IEC 62040-1-1.2002 “Uninterruptible power systems (UPS) - Part 1-1. General and safety requirements for UPS used in operator access areas”. Compare this Part with IEC 62040-1-1.2002, there are the following technical differences. 4.5.15 of this Part is revised to “Unless otherwise required by the user, the documents, human-machine interfaces and markings provided to the end user shall use the standard Chinese.” In this Part, annexes A, B, C, D, E, F, G, K, L, M and N are normative, annexes H, J and X are informative. This Part was proposed by China Electrical Equipment Industry Association. This Part shall be under the jurisdiction of National Technical Committee on Power Electronics of Standardization Administration of China (SAC/TC 60). Responsible drafting organizations of this Part. Emerson Network Power Co., Ltd., Shanghai Forward Technology Co., Ltd. Participating drafting organizations of this Part. Delta Electronic Communications Co., Ltd., Qingdao Rectifier Manufacturing Co., Ltd., Xi’an Power Electronics Research Institute, Qingdao Economic and Technological Development Zone Chuangtong Technology Development Co., Ltd. Main drafters of this Part. Qiu Jianqing, Wang Aosheng, Jiang Weishi, Zhang Xifan, Wei Hongqi, Sui Xueli, Wu Shengzhang, Shao Mingle, Zhou Guanyun, Wang Ying, Wang Weihui. Uninterruptible power systems (UPS) – Part 1-1. General and safety requirements for UPS used in operator access areas 1 Scope and specific applications 1.1 Scope This Part of GB 7260 applies to electronic uninterruptible power systems with an electrical energy storage device in the d.c. link. This Part refers to the relevant contents of GB 4943-2001 and IEC 60950-1.2001. The primary function of the uninterruptible power systems (UPS) covered by this Part is to ensure continuity of an alternating power source. The UPS may also serve to improve the quality of the power source by keeping it within specified characteristics. Notes on regional differences in relevant clauses of GB 4943-2001 and IEC 60950-1. 2001 also apply. This Part is applicable to UPS which are movable, stationary, fixed or for building-in, for use on low-voltage distribution systems and intended to be installed in any operator accessible area. This Part specifies requirements to ensure safety for the operator and layman who may come into contact with the equipment and, where specifically stated, for the service person. This Part is intended to ensure the safety of installed UPS, both as a single UPS unit or as a system of interconnected UPS units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer. This Part does not cover d.c. supplied electronic ballasts (IEC 60924 and IEC 60925), UPS intended to be installed in separated electrical locations and UPS based on rotating machines. The relevant general and safety requirements for UPS installed in restricted access locations are given in GB 7260.4; electromagnetic compatibility (EMC) requirements and definitions are given in GB 7260.2. 1.2 Specific applications Even if this Part does not cover all types of UPS, it may be taken as a guide for such equipment. Requirements additional to those specified in this Part may be necessary for specific applications, for example. ...