HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

GB 5009.251-2016 English PDF

GB 5009.251-2016_English: PDF (GB5009.251-2016)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 5009.251-2016English125 Add to Cart 0--9 seconds. Auto-delivery Determination of 1, 2-propanediol in foods Valid GB 5009.251-2016


BASIC DATA
Standard ID GB 5009.251-2016 (GB5009.251-2016)
Description (Translated English) Determination of 1, 2-propanediol in foods
Sector / Industry National Standard
Classification of Chinese Standard X09
Word Count Estimation 10,143
Date of Issue 2016-08-31
Date of Implementation 2017-03-01
Older Standard (superseded by this standard) NY/T 1662-2008; GB/T 23813-2009
Regulation (derived from) Announcement of the State Administration of Public Health and Family Planning 2016 No.11


GB 5009.251-2016 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National Food Safety Standard - Determination of 1,2- propylene glycol in food ISSUED ON. AUGUST 30, 2016 IMPLEMENTED ON. MARCH 01, 2017 Issued by. National Health and Family Planning Commission of PRC Table of Contents Foreword ... 4  1 Scope ... 5  Method One -- Gas chromatography ... 5  2 Principle ... 5  3 Reagents and materials ... 5  4 Apparatus ... 6  5 Analysis steps ... 6  6 Expression of analysis results ... 9  7 Precision ... 9  8 Other ... 9  Method Two -- Gas chromatography-mass spectrometry ... 9  9 Principle ... 10  10 Reagents and materials ... 10  11 Apparatus ... 11  12 Analysis steps ... 11  13 Expression of analysis results ... 13  14 Precision ... 13  15 Other ... 13  Annex A Gas chromatogram of 1,2-propylene glycol standard sample solution ... 14  Annex B Selective ion chromatogram and ion mass spectrum of 1,2-propylene glycol ... 15  National Food Safety Standard - Determination of 1,2- propylene glycol in food 1 Scope This Standard specifies the methods that use gas chromatography and gas chromatography-mass spectrometry to determine 1,2-propylene glycol in food. Method One of this Standard is applicable to the determination of 1,2-propylene glycol in pastries, puffed food, cream, cheese, soy products, milk tablets, wet noodle products, frozen drinks, liquid milk, vegetable protein drinks, milk powder, butter, cream. Method Two is applicable to the determination of 1,2- propylene glycol in pastries, puffed food, cheese, soy products, milk tablets, wet noodle products. Method One -- Gas chromatography 2 Principle 1,2-propylene glycol in the specimen is extracted by absolute ethanol. After the extract is filtered, use gas chromatography to determine. Characterize by retention time. Quantify by external standard method. 3 Reagents and materials Unless otherwise stated, the reagents used in this method are analytically pure, the water is grade two water specified in GB/T 6682. 3.1 Reagents 3.1.1 Anhydrous ethanol (C2H5OH). 3.1.2 Sea sand. 3.1.3 Acetonitrile (CH3CN). 3.1.4 Hexane [CH3(CH2)4CH3]. 3.2 Preparation of reagent The specimen is crushed by the mincer. Accurately weigh 5 g of well-mixed specimen (to the nearest of 0.01g) to a 100mL stoppered conical flask. Add into 50.0 mL of absolute ethanol. Vortex and mix for 2min, then perform oscillation extraction for 40min. After standing for 1h, use 0.45μm organic phase filter membrane to filter. The filtrate obtained is put into gas chromatograph for analysis. 5.1.2 Wet noddle products The specimen is crushed by the mincer. Accurately weigh 2 g of well-mixed specimen (to the nearest of 0.01g) into the mortar. Add an appropriate amount of sea sand (the mass ratio of sea sand to sample is about 3.1 to 4.1) to grind into dry powder. Transfer all to the 100mL stoppered conical flask. Add into 50.0 mL of absolute ethanol. Vortex and mix for 2min, then perform oscillation extraction for 40min. After standing for 1h, use 0.45μm organic phase filter membrane to filter. The filtrate obtained is put into gas chromatograph for analysis. 5.1.3 Frozen drinks A solid specimen is placed in a dry beaker to unfreeze. After melting, use a glass rod to smash and stir evenly. The liquid specimen is put at room temperature and shaken evenly. Accurately weigh 10 g of well-mixed specimen (to the nearest of 0.01g) into a 50mL stoppered colorimetric tube. Use absolute ethanol to set volume. Vortex and mix for 2min. After standing for 1h (centrifuge at 8000 r/min for 5min if necessary), use 0.45μm organic phase filter membrane to filter. The filtrate obtained is put into gas chromatograph for analysis. 5.1.4 Liquid milk, vegetable protein drinks Accurately weigh 10 g of well-mixed specimen (to the nearest of 0.01g) into a 50mL stoppered colorimetric tube. Use absolute ethanol to set volume. Vortex and mix for 2min. After standing for 1h (centrifuge at 8000 r/min for 5min if necessary), use 0.45μm organic phase filter membrane to filter. The filtrate obtained is put into gas chromatograph for analysis. 5.1.5 Milk powder Accurately weigh 2 g of well-mixed specimen (to the nearest of 0.01g) into a 50mL stoppered colorimetric tube. Use 8 mL of 40°C water to dissolve and well mix. Use absolute ethanol to set volume. Vortex and mix for 2min. After standing for 1h (centrifuge at 8000 r/min for 5min if necessary), use 0.45μm organic phase filter membrane to filter. The filtrate obtained is put into gas chromatograph for analysis. 5.1.6 Butter, cream Inject the specimen solution into the gas chromatograph. Obtain the peak area of corresponding 1,2-propylene glycol. According to the standard curve, obtain the mass concentration of 1,2-propylene glycol in the testing liquid. See Figure A.1 for standard gas chromatograph of 1,2-propylene glycol. 6 Expression of analysis results The content of 1,2-propylene glycol in specimen is calculated according to formula (1). where, X - the content of 1,2-propylene glycol in specimen, in grams per kilogram (g/kg); c - the concentration of 1,2-propylene glycol in specimen solution found in the standard working curve, in microgram per milliliter (µg/mL); V - the set volume of specimen, in milliliters (mL); m - the specimen mass, in grams (g); 1000 - the conversion coefficient. The calculated results are expressed as the arithmetic mean of two independent determinations obtained under repetitive conditions. The result remains three digits after the decimal point. 7 Precision The absolute difference between two independent determinations obtained under repeatability conditions shall not exceed 10% of the arithmetic mean. 8 Other When the sampling amount is 5 g, the detection limit of this Standard is 0.01 g/kg; the limit of quantification is 0.03 g/kg. Method Two -- Gas chromatography-mass 11 Apparatus 11.1 Gas chromatography-mass spectrometry (GC-MS). EI source. 11.2 Analytical balances. resolutions of 0.01g and 0.0001g. 11.3 Mincer. 11.4 Vortex mixer. 11.5 Cyclotron oscillator. 12 Analysis steps 12.1 Preparation of specimen 12.1.1 Pastries, puffed food, cheese, soy products, milk tablets The specimen is crushed by the mincer. Accurately weigh 5 g of well-mixed specimen (to the nearest of 0.01g) to a 100mL stoppered conical flask. Add into 50 mL of absolute ethanol. Vortex and mix for 2min, then perform oscillation extraction for 40min. After standing for 1h, use anhydrous sodium sulfate (about 2 g) to filter. The filtrate obtained is put into gas chromatography-mass spectrometry for analysis. 12.1.2 Wet noodle products The specimen is crushed by the mincer. Accurately weigh 2 g of well-mixed specimen (to the nearest of 0.01g) into the mortar. Add an appropriate amount of sea sand (the mass ratio of sea sand to sample is about 3.1 to 4.1) to grind into dry powder. Transfer all to the 100mL stoppered conical flask. Add into 50 mL of absolute ethanol. Vortex and mix for 2min, then perform oscillation extraction for 40min. After standing for 1h, use anhydrous sodium sulfate (about 2 g) to filter. The filtrate obtained is put into gas chromatography-mass spectrometry for analysis. 12.2 Instrument reference conditions 12.2.1 Chromatographic column. bonded/crosslinked polyethylene glycol stationary phase quartz capillary column, 60m × 0.25mm, 0.25μm, or equivalent column. 12.2.2 Carrier gas. high purity helium; constant current mode, column flow rate of 1.0 mL/min. 12.2.3 Use program temperature rise. Column initial temperature is 80°C. 13 Expression of analysis results The content of 1,2-propylene glycol in specimen is calculated according to formula (2). where, X - the content of 1,2-propylene glycol in specimen, in grams per kilogram (g/kg); c - the concentration of 1,2-propylene glycol in specimen solution found in the standard working curve, in microgram per milliliter (µg/mL); V - the set volume of specimen, in milliliters (mL); m - the specimen mass, in grams (g); 1000 - the conversion coefficient. The calculated results are expressed as the arithmetic mean of two independent determinations obtained under repetitive conditions. The result remains three digits after the decimal point. 14 Precision The absolute difference between two independent determinations obtained under repeatability conditions shall not exceed 10% of the arithmetic mean. 15 Other When the sampling amount is 5 g, the detection limit of this Standard is 0.002 g/kg; the limit of quantification is 0.006 g/kg. ......

Similar standards: GB 5009.259-2023  GB 5009.240-2023  
Similar PDFs (Auto-delivered in 9 seconds): GB 5009.251-2016  GB 5009.284-2021  GB 1903.9-2015  GB 1886.98-2016