Standard ID | GB 37489.5-2019 (GB37489.5-2019) | Description (Translated English) | Hygienic design specification for public places -- Part 5: Barber and beauty | Sector / Industry | National Standard | Classification of Chinese Standard | C51 | Classification of International Standard | 13.020 | Word Count Estimation | 6,640 | Date of Issue | 2019-04-04 | Date of Implementation | 2019-11-01 | Drafting Organization | Shanghai Center for Disease Control and Prevention, Shanghai Municipal Health Commission Supervision Institute, Fudan University, East China Architectural Design and Research Institute, Jiangsu Huaian City Health Supervision Institute | Administrative Organization | National Health Commission of the People's Republic of China | Proposing organization | National Health Commission of the People's Republic of China | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB 37489.5-2019
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 13.020
C 51
Partially replacing GB 9666-1996
Hygienic Design Specification for Public Places -
Part 5: Barber and Beauty
ISSUED ON: APRIL 4, 2019
IMPLEMENTED ON: NOVEMBER 1, 2019
Issued by: State Administration for Market Regulation;
Standardization Administration of the People’s Republic of
China.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Basic Requirements ... 5
4 Overall Layout and Function Division ... 5
5 Monomer ... 6
6 Heating Ventilation Air Conditioning ... 7
7 Water Drainage ... 7
8 Electrical Design ... 7
Foreword
In this Part, 5.1.2 is recommended clause; the remaining clauses are mandatory.
The series of hygienic standards for public places are constituted of five standards:
GB/T 18204 Examination Methods for Public Places; GB 37487 Health Management
Specification for Public Places; GB 37488 Hygienic Indicators and Limits for Public
Places; GB/T 37489 Hygienic Design Specification for Public Places; GB/T 37678
Hygienic Evaluation Specification of Public Places.
GB 37489 Hygienic Design Specification for Public Places is divided into five parts:
-- Part 1: General Requirements;
-- Part 2: Public Accommodation;
-- Part 3: Artificial Swimming Place;
-- Part 4: Bathing Buildings;
-- Part 5: Barber and Beauty.
This is the fifth part of GB 37489.
This Part was drafted in accordance with the rules in GB/T 1.1-2009.
This Part partially replaces the content of design-related hygienic requirements in: GB
9666-1996 Hygienic Standard for Barber Shop and Beauty Shop.
In comparison with GB 9666-1996, this Part has several main technical changes as
follows:
-- Hygienic requirements of overall layout and function division are refined;
-- Hygienic requirements of barber shop and beauty shop design are refined;
-- Hygienic requirements of cleaning and disinfection room (zone) and storage
room (zone) are added;
-- Hygienic requirements of heating ventilation air conditioning are refined;
-- Hygienic requirements of water supply and drainage, and electrical design are
added.
This Part was proposed by and shall be under the jurisdiction of National Health
Commission of the People’s Republic of China.
The drafting organizations of this Part: Shanghai Municipal Center for Disease Control
Hygienic Design Specification for Public Places -
Part 5: Barber and Beauty
1 Scope
This Part of GB 37489 stipulates the basic requirements of newly constructed,
expanded and re-constructed barber and beauty places; and the hygienic design
requirements of overall layout, function division, monomer, heating ventilation air
conditioning, water drainage and electrical design.
This Part is applicable to barber and beauty shops.
This Part is not applicable to medical beauty places.
2 Normative References
The following documents are indispensable to the application of this document. In
terms of references with a specified date, only versions with a specified date are
applicable to this document. In terms of references without a specified date, the latest
version (including all the modifications) is applicable to this document.
GB 37489.1 Hygienic Design Specification for Public Places - Part 1: General
Requirements
JGJ 16 Code for Electrical Design of Civil Buildings
3 Basic Requirements
Barber and beauty places shall comply with the requirements in GB 37489.1.
4 Overall Layout and Function Division
4.1 Functional areas like beauty area, hairdressing area, cleaning and disinfection
room (zone), storage room (zone) and locker room (wardrobe) shall be set up and
reasonably distributed.
4.2 In terms of places with beauty and hairdressing service, beauty and hairdressing
operation areas shall be separated.
4.3 In terms of hairdressing places with a business area of above 50 m2, independent
work cells shall be set up for hair-perming and hair-dyeing. In terms of hairdressing
...
|