HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (15 Sep 2024)

GB 37489.5-2019 English PDF

GB 37489.5-2019_English: PDF (GB37489.5-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 37489.5-2019English90 Add to Cart 0--9 seconds. Auto-delivery Hygienic design specification for public places -- Part 5: Barber and beauty Valid GB 37489.5-2019
Standards related to: GB 37489.5-2019

BASIC DATA
Standard ID GB 37489.5-2019 (GB37489.5-2019)
Description (Translated English) Hygienic design specification for public places -- Part 5: Barber and beauty
Sector / Industry National Standard
Classification of Chinese Standard C51
Classification of International Standard 13.020
Word Count Estimation 6,640
Date of Issue 2019-04-04
Date of Implementation 2019-11-01
Drafting Organization Shanghai Center for Disease Control and Prevention, Shanghai Municipal Health Commission Supervision Institute, Fudan University, East China Architectural Design and Research Institute, Jiangsu Huaian City Health Supervision Institute
Administrative Organization National Health Commission of the People's Republic of China
Proposing organization National Health Commission of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB 37489.5-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.020 C 51 Partially replacing GB 9666-1996 Hygienic Design Specification for Public Places - Part 5: Barber and Beauty ISSUED ON: APRIL 4, 2019 IMPLEMENTED ON: NOVEMBER 1, 2019 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Basic Requirements ... 5 4 Overall Layout and Function Division ... 5 5 Monomer ... 6 6 Heating Ventilation Air Conditioning ... 7 7 Water Drainage ... 7 8 Electrical Design ... 7 Foreword In this Part, 5.1.2 is recommended clause; the remaining clauses are mandatory. The series of hygienic standards for public places are constituted of five standards: GB/T 18204 Examination Methods for Public Places; GB 37487 Health Management Specification for Public Places; GB 37488 Hygienic Indicators and Limits for Public Places; GB/T 37489 Hygienic Design Specification for Public Places; GB/T 37678 Hygienic Evaluation Specification of Public Places. GB 37489 Hygienic Design Specification for Public Places is divided into five parts: -- Part 1: General Requirements; -- Part 2: Public Accommodation; -- Part 3: Artificial Swimming Place; -- Part 4: Bathing Buildings; -- Part 5: Barber and Beauty. This is the fifth part of GB 37489. This Part was drafted in accordance with the rules in GB/T 1.1-2009. This Part partially replaces the content of design-related hygienic requirements in: GB 9666-1996 Hygienic Standard for Barber Shop and Beauty Shop. In comparison with GB 9666-1996, this Part has several main technical changes as follows: -- Hygienic requirements of overall layout and function division are refined; -- Hygienic requirements of barber shop and beauty shop design are refined; -- Hygienic requirements of cleaning and disinfection room (zone) and storage room (zone) are added; -- Hygienic requirements of heating ventilation air conditioning are refined; -- Hygienic requirements of water supply and drainage, and electrical design are added. This Part was proposed by and shall be under the jurisdiction of National Health Commission of the People’s Republic of China. The drafting organizations of this Part: Shanghai Municipal Center for Disease Control Hygienic Design Specification for Public Places - Part 5: Barber and Beauty 1 Scope This Part of GB 37489 stipulates the basic requirements of newly constructed, expanded and re-constructed barber and beauty places; and the hygienic design requirements of overall layout, function division, monomer, heating ventilation air conditioning, water drainage and electrical design. This Part is applicable to barber and beauty shops. This Part is not applicable to medical beauty places. 2 Normative References The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB 37489.1 Hygienic Design Specification for Public Places - Part 1: General Requirements JGJ 16 Code for Electrical Design of Civil Buildings 3 Basic Requirements Barber and beauty places shall comply with the requirements in GB 37489.1. 4 Overall Layout and Function Division 4.1 Functional areas like beauty area, hairdressing area, cleaning and disinfection room (zone), storage room (zone) and locker room (wardrobe) shall be set up and reasonably distributed. 4.2 In terms of places with beauty and hairdressing service, beauty and hairdressing operation areas shall be separated. 4.3 In terms of hairdressing places with a business area of above 50 m2, independent work cells shall be set up for hair-perming and hair-dyeing. In terms of hairdressing ...