HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (2 Feb 2025)

GB 28232-2020 English PDF (GB 28232-2011)

GB 28232-2020_English: PDF (GB28232-2020)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 28232-2020English225 Add to Cart 0--9 seconds. Auto-delivery Hygienic requirements for ozone disinfector Valid GB 28232-2020
GB 28232-2011English150 Add to Cart 0--9 seconds. Auto-delivery Safety and sanitation standard for ozone generator Obsolete GB 28232-2011


BASIC DATA
Standard ID GB 28232-2020 (GB28232-2020)
Description (Translated English) Hygienic requirements for ozone disinfector
Sector / Industry National Standard
Classification of Chinese Standard C50
Classification of International Standard 11.080
Word Count Estimation 18,143
Date of Issue 2020-04-09
Date of Implementation 2020-11-01
Drafting Organization Shanghai Center for Disease Control and Prevention, China Center for Disease Control and Prevention, Environmental and Health-related Product Safety Institute, Chinese People's Liberation Army Center for Disease Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Shandong Provincial Center for Disease Control and Prevention, Heilongjiang Provincial Center for Disease Control and Prevention, Zhejiang Provincial Center for Disease Control and Prevention
Administrative Organization National Health Commission of the People's Republic of China
Proposing organization National Health Commission of the People's Republic of China
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration

BASIC DATA
Standard ID GB 28232-2011 (GB28232-2011)
Description (Translated English) Safety and sanitation standard for ozone generator
Sector / Industry National Standard
Classification of Chinese Standard C59
Classification of International Standard 11.080
Word Count Estimation 14,148
Date of Issue 2011-12-30
Date of Implementation 2012-05-01
Quoted Standard GB/T 191; GB/T 1408; GB/T 2829; GB 5749; GB 9706.1; GB/T 14710; GB 18466; disinfection technical specifications Ministry of Health, 2002; disinfection product label instructions management practices Ministry of Health 2005
Drafting Organization Sichuan University School of Public Health
Administrative Organization Ministry of Health
Regulation (derived from) Announcement of Newly Approved National Standards No. 23 of 2011
Proposing organization People's Republic of China Ministry of Health
Issuing agency(ies) Ministry of Health of People's Republic of China; Standardization Administration of China
Summary This Chinese standard specifies the used water, air and surface disinfection ozone generator technical requirements, scope of application, use, test methods, marking and packaging, transportation and storage, labeling and use instructions and precautions. This standard applies to physically preparing for the disinfection of ozone and ozone generators. This standard does not apply to chemically preparing ozone ozone generator.


GB 28232-2020 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.080 C 50 Replacing GB 28232-2011 Hygienic requirements for ozone disinfector ISSUED ON: APRIL 09, 2020 IMPLEMENTED ON: NOVEMBER 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of PRC. Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions ... 6  4 Raw material requirements ... 7  5 Technical requirements ... 9  6 Application scope ... 14  7 Method of use ... 14  8 Testing method ... 17  9 Transportation and storage ... 20  10 Nameplate and instruction manual ... 20  Appendix A (Normative) Ozone concentration determination method ... 22  Appendix B (Normative) Ozone output determination method ... 25  Appendix C (Normative) Ozone power consumption determination method .. 27  Hygienic requirements for ozone disinfector 1 Scope This standard specifies the raw material requirements, technical requirements, application scope, use methods, inspection methods, transportation and storage, nameplates and instruction manual for use of ozone disinfectors. This standard applies to ozone disinfectors that generate ozone through dielectric barrier discharge, ultraviolet radiation, electrolysis. 2 Normative references The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB 5749 Standards for drinking water quality GB/T 5750.10 Standard examination methods for drinking Water - Disinfection by-products parameters GB/T 15436 Ambient air - Determination of nitrogen oxides - Saltzman method GB 17988 Safety and sanitation requirements for disinfecting tableware cabinet GB/T 18202 Hygienic standard for ozone in indoor air GB 18466 Discharge standard of water pollutants for medical organization GB/T 19258 UV germicidal lamp GB 28235 Safety and sanitary standard for ultraviolet appliance of air disinfection GB 30689 Hygienic requirements for washer-disinfectors employing chemical disinfection for thermolabile endoscopes GB/T 38497 Evaluation method of endoscopic disinfection effect GBZ 2.1 Occupational exposure limits for hazardous agents in the workplace Part 1: Chemical hazardous agents at the inlet end of the ozone generator. 4.1.1.3 Cooling system 4.1.1.3.1 When air is used as the cooling method of the ozone generator, the relative humidity of the cooling air shall be ≤ 85%. 4.1.1.3.2 When water is used as the cooling method of the ozone generator, the cooling water that directly cools the ozone generator is 6.5 ≤ pH ≤ 8.5, chloride content ≤ 250 mg/L, total hardness (calculated as CaCO3) ≤ 450 mg/L, turbidity (scattering turbidity unit) ≤ 1 NTU. 4.1.2 Ultraviolet radiation type 4.1.2.1 The ultraviolet lamp tube shall be made of quartz glass or raw materials with equivalent ultraviolet transmittance. 4.1.2.2 The initial ozone output rate of the ozone ultraviolet germicidal lamp shall not be less than 80% of the indicated value, in line with the requirements of GB/T 19258. 4.1.3 Electrolysis type 4.1.3.1 The material of the electrolytic reaction tank shall be selected from ozone-resistant polymer or metal materials; the membrane electrode material shall be selected from proton exchange membranes and precious metals and their alloys. 4.1.3.2 The gas supply source shall use deionized water with conductivity ≤ 5 µS/cm. 4.2 Ozone disinfector components The parts contacting ozone shall use ozone-resistant materials, to ensure long- term stable operation in an ozone environment. 4.3 Ozone-water mixing device 4.3.1 Ozone-water mixing elements with low energy consumption and high dissolved gas efficiency shall be used; the dissolved gas efficiency shall be ≥ 50%. 4.3.2 A ozone-water separation device shall be installed to separate undissolved gaseous ozone; an ozone tail gas decomposition device shall be installed to decompose the separated ozone gas. 4.4 Monitoring device 5.1.3 By-products 5.1.3.1 With air as the gas source, the concentration of nitrogen oxides (NOx) produced by the ozone disinfector shall not be greater than 2.5% of the ozone concentration. 5.1.3.2 When used for drinking water disinfection, the bromate concentration in the water shall be ≤ 0.01 mg/L; the formaldehyde concentration shall be ≤ 0.9 mg/L. 5.1.4 Ozone leakage The ozone disinfector is used under human conditions; it shall be airtight when using the ozone gas for sterilization. The ozone leakage in the surrounding environment shall be ≤ 0.1 mg/m3. 5.1.5 Residual ozone After one working cycle of ozone disinfection under airtight conditions, the residual amount of ozone gas in the airtight room shall be ≤ 0.16 mg/m3. 5.2 Ultraviolet radiation type ozone disinfector 5.2.1 Basic working conditions Under the conditions of ambient temperature 5 °C ~ 45 °C, relative humidity ≤ 85%, power supply voltage 220 V ± 22 V, power supply frequency 50 Hz ± 1 Hz, the ozone disinfector shall be able to be used continuously. 5.2.2 Performance requirements 5.2.2.1 The ozone gas concentration of the ozone disinfector shall be ≥ 60 mg/m3. 5.2.2.2 After turning on for 5 minutes, the ultraviolet lamp’s radiation illuminance shall be stable under normal working conditions; the fluctuation range shall not exceed 5% of the average value. 5.2.2.3 The effective life of the new UV lamp shall be ≥ 1000 h. 5.2.3 Leakage 5.2.3.1 UV leakage At 30 cm away from the periphery of the disinfector, the UV leakage shall be ≤ 5 µW/cm2. 5.2.3.2 Ozone leakage 6 Application scope It is suitable for disinfection of air, water, tableware, food processing pipelines, medical equipment, medical supplies and surface of objects. 7 Method of use 7.1 Air disinfection 7.1.1 According to the volume of the space to be disinfected and the applicable volume requirements in the product’s instruction manual, select the applicable ozone air disinfector model. 7.1.2 Air disinfection shall be carried out in a closed space and indoors without people. Generally, the ozone concentration is 5 mg/m3 ~ 30 mg/m3, the relative humidity is ≥ 70%, the action time is 30 min ~ 120 min. 7.1.3 When performing air disinfection, the doors and windows shall be closed; the power is turned on; the indicator light is on; the switch or remote control is pressed; the disinfection time is set; the disinfector starts to work. After a disinfection cycle according to the set procedure, the disinfection treatment is completed. 7.2 Water disinfection 7.2.1 It can be used for disinfection of drinking water, water for diagnosis and treatment in medical institutions (non-injection water), sewage, swimming pool water, central air conditioning cooling water, condensate water in public places. 7.2.2 According to the type of water to be disinfected, select the corresponding specifications of ozone water disinfector models according to relevant standards. Install and operate the ozone water disinfector in accordance with the requirements of the instruction manual. 7.2.3 When used for disinfection of drinking water, the exposure time of ozone and water before the water leaves the factory shall be ≥ 12 min; the residual ozone in the water after disinfection shall be ≤ 0.3 mg/L; the residual ozone in the water at the end of the pipe network shall be ≥ 0.02 mg/L . 7.2.4 For the disinfection of water for diagnosis and treatment (non-injection water) in medical institutions, the general ozone input amount is 0.5 mg/L ~ 1.5 mg/L, the remaining ozone concentration in the water is maintained at 0.1 mg/L ~ 0.5 mg/L for 5 min ~ 10 min. For poor water quality or serious pollution, the ozone input is 3 mg/L ~ 6 mg/L. 7.4.1.3 When using ozone water to sterilize medical equipment and supplies, install an ozone water disinfector in accordance with the instruction manual. When disinfecting, put the medical equipment and supplies that need to be disinfected after washing into the container; turn on the power; soak in ozone water or continue to rinse and disinfect for a specified time to complete the disinfection. During disinfection, the ozone concentration in the water shall be ≥ 10 mg/L; the disinfection time shall be ≥ 40 min. 7.4.2 Disinfection of bed unit 7.4.2.1 According to the instruction manual of bed unit and its supplies to be disinfected, select the applicable ozone bed unit disinfector (machine) model. 7.4.2.2 When using, take out the sterilization sealed bag equipped with the bed unit disinfector, put the items to be sterilized into the bag; seal the bag opening; insert the air pipe on the disinfector into the air nozzle of the sealed bag; turn on the power; turn on the power switch; start the disinfection button, the disinfector starts to work (the sealed bag needs to be vacuumed before disinfection) until the disinfection process is all over. During disinfection, the ozone concentration in the sealed bag is generally ≥ 200 mg/L; the relative humidity is ≥ 70%; the maintenance time is ≥ 30 min. 7.4.3 Endoscope disinfection 7.4.3.1 According to the instruction manual of the type of endoscope to be sterilized, select the applicable ozone automatic endoscope disinfector (machine) model. 7.4.3.2 When disinfecting the endoscope, first clean the used endoscope by hand; then put it into the machine tank according to the natural bending state of the endoscope; connect the air and water supply pipes; cover the inner cover of the decontamination tank; meanwhile close the cover of the basin. Turn on the power; turn on the power switch; select the disinfection program and time according to the type of endoscope; start the disinfection button, the disinfector will start working until the disinfection process is all over and the disinfection treatment is completed. When disinfecting, it is generally required that the ozone concentration in the water shall be ≥ 11 mg/L. 7.5 Surface disinfection of object 7.5.1 According to the size of the surface area of the object to be disinfected and the requirements of the product instruction manual, select the applicable ozone surface disinfector model. 7.5.2 When using ozone gas to disinfect the surface of an object, it shall close the doors and windows; turn on the power, the indicator light is on; press the switch or remote control; set the disinfection time, the disinfector starts to work. 8.2.1 Performance requirements 8.2.1.1 Ozone concentration of ozone disinfector It is determined according to the method specified in Appendix A. 8.2.1.2 Ultraviolet radiation illuminance and its fluctuation range 8.2.1.2.1 Ultraviolet radiation illuminance It is determined according to the method specified in GB 28235. 8.2.1.2.2 Illumination fluctuation range of ultraviolet radiation When starting up for 5 min, 10 min, 15 min, 30 min, 60 min, 120 min, the irradiance of the ultraviolet germicidal lamp is measured respectively, to calculate the average value and its fluctuation range. 8.2.1.2.3 Effective life of UV germicidal lamp It is determined according to the method specified in GB 28235. 8.2.2 Leakage 8.2.2.1 UV leakage After turning on the ozone disinfector for 5 minutes to stabilize, at a distance of 30 cm from the outer surface of the disinfector, use an ultraviolet radiation illuminance meter to detect the ultraviolet radiation illuminance. 8.2.2.2 Ozone leakage It is determined according to the method specified in GB/T 18202. 8.2.3 Residual ozone It is determined according to the method of 8.1.4. 8.3 Electrolysis type ozone disinfector 8.3.1 Performance requirements 8.3.1.1 Ozone concentration of ozone disinfector It is determined according to the method specified in Appendix A. 8.3.1.2 Power consumption of ozone disinfector It is determined according to the method specified in Appendix C. Appendix A (Normative) Ozone concentration determination method A.1 Iodometry A.1.1 Purpose The chemical method is used in the laboratory to accurately determine the concentration of ozone gas or ozone contained in ozone water produced by the ozone disinfector. A.1.2 Test equipment A.1.2.1 Pipette (1 mL, 5 mL, 10 mL, 25 mL). A.1.2.2 Burette (2 mL, 5 mL, 10 mL, 25 mL, 50 mL). A.1.2.3 Iodine measuring flask (100 mL, 250 mL). A.1.2.4 Volumetric flasks (50 mL, 100 mL, 250 mL, 500 mL, 1000 mL). A.1.2.5 Conical flask (100 mL, 250 mL, 500 mL). A.1.2.6 Balance (0.1 mg). A.1.2.7 Atmospheric sampler. A.1.2.8 Other equipment. A.1.3 Reagents A.1.3.1 Prepare 3 mol/L sulfuric acid, 200 g/L potassium iodide and 5 g/L starch solutions. A.1.3.2 Prepare and calibrate 0.05 mol/L sodium thiosulfate titrant. A.1.4 Test method A.1.4.1 Sampling: When detecting the concentration of ozone aqueous solution, precision take a sample of 100.0 mL ~ 300.0 mL (when the concentration is low, but not less than 10 mg/L, take 400.0 mL). Place it in a 500 mL conical flask with stopper. Add 20 mL of 200 g/L potassium iodide solution and mix well. Then add 5 mL of 3 mol/L sulfuric acid. Add the stopper. Let it stand for 5 min. Note: When sampling involves water flow, the water flow is set in accordance Where: I - The light intensity after the beam penetrates the ozone; Io - Intensity of incident light without ozone; K - The absorption coefficient of ozone to light wavelength; L - The length of the optical path of the ozone sample cell; C - Ozone concentration. According to this formula, under the condition of known K and L values, the ozone concentration can be measured by determining the I/I0 value. A.2.1.2 Determination According to the application, it is divided into two types: detecting air ozone and detecting water-soluble ozone. Follow the instruction manual of the instrument. Before using the instrument, it can be used only after it has been certified by a national authorized measurement unit. A.2.2 Electrochemical method A.2.2.1 Principle The ozone in water produces electrochemical reduction on the electrochemical surface: O3 + H2O + 2e- →O2 + 2OH- The current characteristic curve in the electrochemical circuit is proportional to the concentration of molecular ozone in the solution. The electrochemical detector is mainly used for on-line continuous detection and control of water-soluble ozone concentration. A.2.2.2 Operation The widely used "membrane electrode" dissolved ozone detector can be used. Before using the instrument, it can be used only after it has been certified by a national authorized measurement unit. ......


GB 28232-2011 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS11.080 C 59 Safety and sanitation standard for ozone generator ISSUED ON. DECEMBER 30, 2011 IMPLEMENTED ON. MAY 1, 2012 Issued by. Ministry of Health of the People's Republic of China; Standardization Administration Committee. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions ... 5  4 Specifications and classifications ... 6  5 Name and model ... 7  6 Technical requirements ... 7  7 Application scope ... 9  8 Application methods ... 9  9 Inspection and methods ... 10  10 Marking and packing ... 13  11 Transportation and storage ... 14  12 Labels and instructions ... 14  13 Precautions ... 15  Appendix A ... 16  Appendix B ... 19  Appendix C ... 21  Foreword All technical content of this standard is mandatory. The appendix A, appendix B and appendix C of this standard are normative. This standard was put forward by and shall be under the jurisdiction of the Ministry of Health of People's Republic of China. Drafting organizations of this standard. Huaxi School of public health of Sichuan University, Chengdu Tian Tian Medical Electrical Technology Co., Ltd. The main drafters of this standard. Zhang Zhaowu, Jiang Tianhua, Wang Guoqing, Liu Hengchuan. Safety and sanitation standard for ozone generator 1 Scope This standard specifies the technical requirements, application scope, application methods, inspection methods, marking and packaging, transportation and storage, labels and instructions, and matters needing attention for ozone generator that is used for disinfection of water, air and object surfaces. This standard is applicable to ozone generator that produces ozone by the physical method and is used for disinfection. This standard is not applicable to ozone generator that produces by the chemical method. 2 Normative references The clauses in the following documents become the provisions of this standard by reference in this standard. For dated references, subsequent amendments (excluding corrections) or revisions do not apply to this standard. However, the parties are encouraged to research and reach an agreement on whether the latest version of these documents can be used according to this standard. For undated references, the latest edition applies to this standard. GB/T 191 Packaging. Pictorial marking for handling of goods GB/T 1408 Test method for power frequency electrical strength of solid insulating materials GB/T 2829 Sampling procedures and tables for periodic inspection by attributes GB 5749 Standards for drinking water quality GB 9706.1 Medical electrical equipment - Part 1. General requirements for safety GB/T 14710 Environmental requirement and test methods for medical electrical equipment GB 18466 Discharge standard of water pollutants for medical organization Disinfection technical specification (2002 Edition), Ministry of Health After the gas is penetrated, phenomenon of voltage decreases between the poles and the dark glow around the electrode. 3.9 Epilogue gas An ozone-containing gas that is produced in an ozone water generator but not completely dissolved in water. 3.10 Dew point The temperature at which the gas source starts to become dew; the lower the relative humidity of the gas, the lower the dew point temperature. 3.11 Specific consumption The electric energy that is consumed by the ozone generator to produce a unit weight of ozone. 4 Specifications and classifications 4.1 Specifications The specifications of the ozone generator are represented by the amount of ozone produced in a unit time (the basic unit is g/h). 4.2 Classification 4.2.1 Type 4.2.1.1 Work type is divided into ozone generator or ozone-water generator. 4.2.1.2 Placement is divided into table, standing, mobile and separate type. 4.2.2 Model marking 4.2.2.1 The structure of the ozone generation unit is divided into tube type (G) and plate type (B). 4.2.2.2 The control methods of the ozone generator are divided into common type (fixed type, P) and adjustable type [manual-adjusted (R), and program-adjusted (C)]. 4.2.2.3 The working frequency of the power supply is divided into power frequency, medium frequency and high frequency. b) The frequency of the power supply is 50Hz±1Hz, the voltage is 220V±22V, the atmospheric pressure is 86kPa~106kPa, and the relative humidity is 65%~85%, the temperature is room temperature; c) The exit gas temperature should be < 27°C; d) The output ozone concentration of closed type ozone generator should be ≥ 12mg/L. When the above conditions are changed, the corresponding indicator such as discharge (corona discharge or glow discharge) per unit area of ozone yield, concentration, output and electricity consumption should be measured according to the specific conditions. 6.2.2 All kinds of electrical insulation parts of the ozone generator should meet the requirements of high voltage insulation performance and structure. The insulation parts in the environment of the glow discharge, ozone oxidation should also meet the requirements of GB 9706.1. 6.2.3 For those using water as coolant, the consumption of cooling water per kilogram of ozone should not exceed 1.5×103 kg. 6.2.4 The average life-span should be ≥ 20 000 h;accumulative working time without fault should be ≥ 8 000 h. 6.3 Conditions for using ozone generator Under the condition of ambient temperature below 45°C, atmospheric pressure 86kPa~106kPa, relative humidity 65%~85%, and the cooling water temperature lower than 35°C, the ozone generator should be able to be used continuously. 6.4 Requirements for disinfection 6.4.1 Disinfection of air 6.4.1.1 Air disinfection should be carried out in a closed space with no human inside. The ozone concentration should be ≥ 20mg/m3, the action time should be ≥ 30min. 6.4.1.2 The effect of disinfection should comply with the related requirements of the “Disinfection technical specification” (2002 Edition). 6.4.2 Disinfection of water 6.4.2.1 It can be used to disinfect medical institutions’ diagnosis-water (non-injection water), dirt-water, and the water in public places. 6.4.2.2 When it is used to disinfect the medical institutions’ diagnosis-water (non- 9.4.1 For ozone generation unit’s performance spot inspection, the sampling ratio is 5%. For example, sampling unit is ozone generating unit in a single ozone generator, and the total number of ozone generation units is < 60, then, the sampling number should be ≥ 3 ozone generating units. The ozone generating unit’s performance test conditions should be in accordance with 6.2.1. 9.4.2 If the data measured by performance test is 10%~20% lower than the performance requirements and the proportion is ≥ 20% of the units checked. Then, re- test can be carried out after finding the causes. If the performance requirements are still not met after re-test, then, increase the sampling proportion of the ozone generating unit to 25%. If there is no failing of the performance requirements, then spot test can be stopped. After expansion of the sampling proportion, if the proportion of failing ozone generating units exceeds 5% of the checked-number, then, the causes should be thoroughly found; and the production can only be resumed after problems are solved. 9.4.3 For new-type products or formal-products that are being manufacturing, when there are major changes in structure, material or process, or when continuous production life of one product exceeds 3 years, then, a number of ozone generation units should be randomly selected to test its performance parameters and service life. 9.5 Exit-factory inspection 9.5.1 Ozone generation unit should be accurately located in the ozone generator. Components for fastening, support and connection should be firmly installed. 9.5.2 Appearance inspection of ozone generator Internal appearance inspection includes. parts of ozone generating unit should be clean, no oil stains, water stains, dust or other foreign objects; the anti-corrosion coating inside of the ozone generator should be smooth and clean with no peeling, chipping or other adverse conditions; The high-voltage power transmission and distribution system should be tidy and should not cause abnormal transmission and distribution. External appearance inspection should include. the external shell surface should be smooth with no scar, bump, dent, or other defects affecting the appearance; protections and other adverse conditions (if on-site external decoration will be done according to the requirements of the buyer, this test can be carried out when appropriate). All kinds of appurtenances (parts) on the external shell should be installed at the accurate location, firmly fastened, and quality acceptable. Any part of the shell shall not obstruct installation, maintenance, cleaning etc. For ozone generators with high pressure device, the shell should be flame-retardant. 9.5.3 The interface of the ozone generator with each instrument (meter), or with 10.2.2 The package shall be suitable for water/land transportation and meet loading requirements. 10.2.3 The text and signs outside the package include the following. a) Company name or trademark, registered address, production address, zip code, contact number; b) Product name, model, specification; c) Product net weight, gross weight, center of gravity, lifting mark; d) Date of production, exit-factory number; e) Power connection condition, input power; f) Storage and transportation marks, such as "fragile items", "Rain fear", "limit of stacking layer", etc., shall conform to the GB/T 191 regulations. 10.2.4 Accessories, spare parts can be packaged separ... ......

Similar standards: GB 28233-2020  GB 28234-2020  
Similar PDFs (Auto-delivered in 9 seconds): GB 28232-2020  GB 28232-2011  GB/T 27947-2020  GB/T 26373-2020