GB 1903.72-2025 PDF English
US$170.00 · In stock · Download in 9 secondsGB 1903.72-2025: National food safety standard - Food additive - Sodium iron (III) ethylenediaminetetraacetate trihydrate Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedureStatus: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivery | Name of Chinese Standard | Status |
| GB 1903.72-2025 | English | 170 |
Add to Cart
|
0-9 seconds. Auto-delivery
|
National food safety standard - Food additive - Sodium iron (III) ethylenediaminetetraacetate trihydrate
| Valid |
Excerpted PDFs (Download full copy in 9 seconds upon purchase)PDF Preview: GB 1903.72-2025
GB 1903.72-2025: National food safety standard - Food additive - Sodium iron (III) ethylenediaminetetraacetate trihydrate ---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB1903.72-2025
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National Food Safety Standard - Food Additive - Sodium
Iron (III) Ethylenediaminetetraacetate Trihydrate
Issued on: MARCH 16, 2025
Implemented on: SEPTEMBER 16, 2025
Issued by. National Health Commission of the People’s Republic of China;
State Administration for Market Regulation.
Table of Contents
Foreword... 3
1 Scope... 4
2 Chemical Name, Molecular Formula, Structural Formula and Relative Molecular
Mass... 4
3 Technical Requirements... 4
Appendix A Inspection Methods... 6
Appendix B Standard Chromatogram of Aminotriacetic acid... 17
National Food Safety Standard - Food Additive - Sodium
Iron (III) Ethylenediaminetetraacetate Trihydrate
1 Scope
This Standard applies to sodium iron (III) ethylenediaminetetraacetate trihydrate, a food
nutritional enhancer produced by the reaction of inorganic iron salts and
Ethylenediaminetetraacetic acid sodium salt as raw materials.
2 Chemical Name, Molecular Formula, Structural Formula
and Relative Molecular Mass
2.1 Chemical name
Sodium iron (III) ethylenediaminetetraacetate trihydrate
2.2 Molecular formula
C10H12FeN2NaO8·3H2O
2.3 Structural formula
2.4 Relative molecular mass
421.09 (by 2022 international relative atomic mass).
3 Technical Requirements
3.1 Sensory requirements
The sensory requirements shall comply with the provisions of Table 1.
Appendix A
Inspection Methods
A.1 Safety tips
Some of the reagents used in the test methods of this Standard are toxic or corrosive.
Appropriate safety and health measures shall be taken during operation. If splashed on the skin,
rinse with water immediately. In severe cases, treatment shall be given immediately. When
using flammable materials, it is strictly forbidden to use open flames for heating.
A.2 General
Unless otherwise specified, the purity of the reagents used in this Standard shall be analytically
pure. The used standard titration solutions, standard solutions for impurity determination,
preparations and products shall be prepared in accordance with the provisions of GB/T 601,
GB/T 602 and GB/T 603 respectively. The test water shall comply with the provisions of Grade
3 water in GB/T 6682.When the solution used in the test is not specified with which solvent it
is prepared, it refers to an aqueous solution.
A.3 Identification test
A.3.1 Reagents and materials
A.3.1.1 Ammonium thiocyanate solution (8 g/L). weigh 0.8 g of ammonium thiocyanate
(accurate to 0.000 1 g), dissolve it in water and make constant volume to 100 mL.
A.3.1.2 Hydrochloric acid solution (V +V). 1 + 9.
A.3.2 Instruments and equipment
A.3.2.1 Balance. sensitivity is 0.000 1 g.
A.3.2.2 UV-visible spectrophotometer (1 cm quartz cuvette).
A.3.3 Identification method
A.3.3.1 Color reaction. Weigh 0.05 g of specimen (accurate to 0.000 1 g); place in a 10 mL
glass test tube; add 5 mL of water to dissolve; add 1.0 mL of ammonium thiocyanate solution
(A.3.1.1); the color of the solution shall not change. Then add 0.5 mL of hydrochloric acid
solution (A.3.1.2); mix well; the solution shall be dark red.
A.3.3.2 Ultraviolet absorption. Weigh 0.1 g of specimen (accurate to 0.000 1 g); dissolve in
water and dilute to 100 mL; shake well; transfer 1 mL to a 50 mL volumetric flask; dilute with
water and make constant volume; shake well. The concentration of the specimen solution is 20
μg/mL. Spectrophotometric determination is performed in the wavelength range of 190 nm ~
700 nm. The solution shall have a maximum absorption peak at a wavelength of 256 nm ± 2
nm.
A.4 Determination of iron content
A.4.1 Method summary
Under strong acidic conditions of sodium iron (III) ethylenediaminetetraacetate trihydrate, free
Fe3+ reacts quantitatively with excess potassium iodide to generate and precipitate I2, which is
then titrated with sodium thiosulfate standard titration solution. The iron content in the
specimen is calculated based on the titration consumption of sodium thiosulfate standard
titration solution.
A.4.2 Reagents and materials
A.4.2.1 Potassium iodide.
A.4.2.2 Hydrochloric acid.
A.4.2.3 Sodium thiosulfate standard titration solution. c(Na2S2O3) = 0.1 mol/L.
A.4.2.4 Starch indicator solution (10 g/L). Weigh 0.5 g of soluble starch and add a small amount
of water to make a paste. Pour 50 mL of boiling water while stirring; boil and stir; then cool
and set aside (prepare immediately before use).
A.4.3 Instruments and equipment
Balance. Sensitivity is 0.000 1 g.
A.4.4 Analysis procedures
Weigh 0.5 g of specimen (accurate to 0.000 1 g); dissolve it in 40 mL of water in an iodine
volume flask; add 3 g of potassium iodide (A.4.2.1) and 20 mL of hydrochloric acid (A.4.2.2);
shake well. Seal the bottle stopper with water; place in a dark place for about 5 min; remove
the stopper and rinse the stopper cover with a small amount of water; titrate with sodium
thiosulfate standard titration solution (A.4.2.3) to the near end point (light yellow); add 2.0 mL
of starch indicator solution (A.4.2.4); and continue titrating until the blue color disappears as
the end point.
While measuring the sample, titrate the blank solution without sample with sodium thiosulfate
standard titration solution (A.4.2.3).
A.4.5 Calculation of results
The mass fraction of iron w1 is expressed in %, and is calculated according to Formula (A.1).
A.5.2.6 Calcium acetate monohydrate standard titration solution (0.25 mol/L). Weigh 44.0 g of
calcium acetate monohydrate (A.5.2.1) (accurate to 0.0001 g); dissolve it in water; transfer it
into a 1,000 mL volumetric flask; and make constant volume to the scale.
A.5.3 Instruments and equipment
A.5.3.1 Balance. Sensitivity is 0.000 1 g
A.5.3.2 pH meter.
A.5.4 Analysis procedures
A.5.4.1 Calibration of calcium acetate monohydrate standard titration solution. Weigh 2.0 g ~
2.1 g of ethylenediaminetetraacetic acid (A.5.2.2) (accurate to 0.000 1 g) and place it in a 250
mL conical flask. Add 150 mL of water; then dissolve it with sodium hydroxide solution
(A.5.2.4) and adjust the pH to 11.0~12.0; add 30 mg of hydroxynaphthol blue indicator
(A.5.2.3); and titrate with calcium acetate monohydrate standard titration solution (A.5.2.6).
When the solution changes from blue to red, it is the end point.
A.5.4.2 Titration operation. Weigh 0.8 g~1.0 g of specimen (accurate to 0.000 1 g); place in a
250 mL conical flask; and add 75 mL of distilled water to dissolve. Use triethanolamine (A.5.2.5)
to adjust the pH of the solution to 9.0.After complexing and masking Fe3+, use sodium
hydroxide solution (A.5.2.4) to adjust the pH of the specimen solution to 12.5~13.0; and the
solution becomes colorless and clear. Add 30 mg of hydroxynaphthol blue indicator (A.5.2.3);
titrate with a calibrated calcium acetate monohydrate solution; and the titration endpoint is
when the solution changes from blue to red.
While measuring the sample, titrate the blank solution without sample with the calibrated
calcium acetate monohydrate standard titration solution.
A.5.5 Calculation of results
The molar concentration c2 of the calcium acetate monohydrate standard titration solution is
expressed in mol/L and is calculated according to Formula (A.2).
Where.
m2 - mass of ethylenediaminetetraacetic acid (A.5.2.2), in g;
V3 - volume of calcium acetate monohydrate standard titration solution (A.5.2.6) consumed for
calibration, in mL;
M2 - molar mass of ethylenediaminetetraacetic acid (A.5.2.2), in g/mol (M2 = 292.24);
A.7.2.5 Phosphoric acid solution (1 mol/L). Measure 6.25 mL of phosphoric acid and dilute it
to 100 mL with water.
A.7.2.6 Aminotriacetic acid standard sample. C6H9NO6, purity >98.0%; CAS number. 139-13-
9.
A.7.2.7 Aminotriacetic acid standard stock solution (10 mg/mL). Weigh 100 mg of
aminotriacetic acid standard sample (A.7.2.6) (accurate to 0.000 1 g); transfer it to a 10 mL
volumetric flask; dissolve it in water and add 0.5 mL of ammonia water; mix; make constant
volume to the scale with water; and shake well.
A.7.2.8 Aminotriacetic acid standard solution (10 mg/L). Weigh 1 g of specimen (accurate to
0.000 1 g) and place in a 100 mL volumetric flask. Add 100 μL of aminotriacetic acid standard
stock solution (A.7.2.7); dilute to scale with copper nitrate solution (A.7.2.4); and shake well.
Ultrasonic treatment to obtain a standard solution.
A.7.3 Instruments and equipment
A.7.3.1 Balance. Sensitivity is 0.000 1 g.
A.7.3.2 High performance liquid chromatograph. With UV detector.
A.7.3.3 pH meter.
A.7.4 Analysis procedures
A.7.4.1 Specimen treatment
Weigh 1 g of specimen (accurate to 0.000 1 g); add 100 μL of ammonia solution (A.7.2.3) and
50 mL copper nitrate solution (A.7.2.4); treat with ultrasound; transfer to a 100 mL volumetric
flask; make constant volume with copper nitrate solution (A.7.2.4); shake well; and obtain the
specimen solution.
A.7.4.2 Chromatographic reference conditions
Precolumn. C8 chromatographic column (4.6 mm×10 mm, 5 μm).
Mobile phase. Measure 10 mL of 25% tetrabutylammonium hydroxide methanol solution
(A.7.2.2); place in 200 mL of water; and then adjust the pH to 7.5±0.1 with 1 mol/L phosphoric
acid. Transfer the solution to a 1,000 mL volumetric flask; add 90 mL of methanol (A.7.2.1);
make constant volume to the scale with water; shake well; filter with a 0.45 μm filter membrane;
degas and set aside.
Chromatographic column. C18 chromatographic column (4.6 mm×150 mm, 5 μm), or other
equivalent chromatographic columns.
Detection wavelength. 244 nm.
Injection volume. 20 μL.
Flow rate. 2.0 mL/min.
A.7.4.3 Specimen analysis
Under the chromatographic reference conditions of A.7.4.2, perform chromatographic analysis
on the standard solution and the specimen solution; record the chromatogram; and calculate the
response value of aminotriacetic acid. Repeat the standard solution measurements for 3 times
to take the average response value. The relative standard deviation of the 3 measurement results
is ≤2.0%. The standard chromatogram of aminotriacetic acid is shown in Appendix B.
A.7.5 Judgment of results
The response value of the aminotriacetic acid chromatographic peak in the specimen solution
does not exceed the difference between the response values of the aminotriacetic acid
chromatographic peaks obtained from the standard solution and the sample solution, that is, the
aminotriacetic acid content in the specimen is ≤0.1%.
The detection limit of this method is 20 mg/kg.
A.8 Determination of chloride (by Cl)
A.8.1 Method summary
In an acidic medium, use a silver electrode as the measuring electrode and a calomel electrode
as the reference electrode; titrate with a silver nitrate standard titration solution; and determine
the reaction endpoint with the help of a potential mutation.
A.8.2 Reagents
A.8.2.1 95% ethanol.
A.8.2.2 Saturated potassium nitrate solution.
A.8.2.3 Sodium hydroxide solution. 200 g/L.
A.8.2.4 Nitric acid solution (V + V). 2+3.
A.8.2.5 Standard silver nitrate titration solution. c(AgNO3) = 0.1 mol/L.
A.8.2.6 Bromophenol blue indicator solution. 0.1% ethanol solution.
A.8.3 Instruments and equipment
A.8.3.1 Balance. Sensitivity is 0.000 1 g.
A.8.3.2 Potentiometric titrator (with silver electrode). Accuracy is 2 mV.
In an acidic medium, sulfate ions in the specimen react with barium ions to form barium sulfate
precipitates, which are compared with the sulfate standard solution treated in the same way to
perform a limit test.
A.9.2 Reagents
A.9.2.1 Hydrochloric acid solution (V + V). 1 + 4.
A.9.2.2 Sodium hydroxide solution. 160 g/L.
A.9.2.3 Barium chloride solution. 0.5 mol/L.
A.9.2.4 Zinc chloride solution. 1 mol/L.
A.9.2.5 Sulfate standard solution. Weigh 2.113 g of anhydrous sodium sulfate (accurate to 0.000
1 g) and dissolve it in water; place it in a 1,000 mL volumetric flask; and dilute to the scale.
Each 1 mL of standard solution is equivalent to 1.430 mg of sulfate.
A.9.2.6 Solution A. Take 5 mL of barium chloride solution (A.9.2.3); add 55 mL of water and
20 mL of 95% ethanol solution to dilute; and then add 0.5 mL of sulfate standard solution
(A.9.2.5) and mix well (prepare it before use).
A.9.2.7 Indicator solution. 0.25% p-nitrophenol solution.
A.9.3 Instruments and equipment
Balance. Sensitivity is 0.01 g.
A.9.4 Analysis procedures
Weigh 1.8 g of specimen (accurate to 0.01 g); add 30 mL of water to dissolve; slowly add 4.5
mL of sodium hydroxide solution (A.9.2.2); stir for 15 min; make constant volume to 50 mL;
and filter. Take 20 mL of filtrate as specimen solution; place in a 50 mL colorimetric tube; add
2 drops of indicator solution (A.9.2.7); and titrate with hydrochloric acid solution (A.9.2.1)
until the solution changes from yellow to colorless. Add 2 mL of zinc chloride solution (A.9.2.4),
and titrate again with hydrochloric acid or sodium hydroxide solution to pH = 2.0.After making
constant volume to 50 mL with water, add 5.0 mL of solution A (A.9.2.6) and mix well. Under
a black background, observe axially and compare the turbidity of the specimen solution with
the standard turbidity solution.
Standard turbidity solution. Measure 20 mL of water and place it in a 50 mL colorimetric tube.
Treat it to pH = 2.0 at the same time as the specimen solution; add 300 μL of sulfate standard
solution (A.9.2.5); make constant volume to 50 mL; and then add 5.0 mL of solution A (A.9.2.6);
and mix well.
A.9.5 Judgment of results
...... Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Tips & Frequently Asked QuestionsQuestion 1: How long will the true-PDF of English version of GB 1903.72-2025 be delivered?Answer: The full copy PDF of English version of GB 1903.72-2025 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice. Question 2: Can I share the purchased PDF of GB 1903.72-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB 1903.72-2025_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 1903.72-2025 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.
How to buy and download a true PDF of English version of GB 1903.72-2025?A step-by-step guide to download PDF of GB 1903.72-2025_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD). Step 2: Search keyword "GB 1903.72-2025". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9
|