HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB 1886.315-2021 PDF English

US$140.00 · In stock · Download in 9 seconds
GB 1886.315-2021: National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB 1886.315-2021English140 Add to Cart 0-9 seconds. Auto-delivery National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB 1886.315-2021
      

Similar standards

GB 1886.316   GB 1886.317   GB 1886.314   GB 1886.320   

GB 1886.315-2021: National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB1886.315-2021
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake ISSUED ON: FEBRUARY 22, 2021 IMPLEMENTED ON: AUGUST 22, 2021 Issued by: National Health Commission of the People's Republic of China; State Administration for Market Regulation.

Table of Contents

1 Scope ... 3 2 Molecular formula, structural formula, and relative molecular mass of iconic components ... 3 3 Technical requirements ... 3 Appendix A Inspection method ... 6 National food safety standard - Food additives - Dactylopius coccus Costa and its aluminum lake

1 Scope

This Standard applies to the food additive Dactylopius coccus Costa aluminum lake, which is obtained from the dry body of the female adult of Dactylopius coccus Costa, as the raw material, which is extracted by water, methanol and/or ethanol solution, and then concentrated, and is further refined by chelating with aluminum salt. 2 Molecular formula, structural formula, and relative molecular mass of iconic components 2.1 Molecular formula Carminic acid: C22H20O13 2.2 Structural formula Carminic acid: 2.3 Relative molecular mass Carminic acid: 492.39 (according to the international relative atomic mass in 2018)

3 Technical requirements

3.1 Sensory requirements

Appendix A

Inspection method A.1 General provisions The reagents and water that are used in this Standard, when no other requirements are specified, refer to analytical reagents and grade-III water which is specified in GB/T 6682. The standard solution, the standard solutions, preparations and products for impurity determination, which are used in the test, are all prepared in accordance with the provisions of GB/T 601, GB/T 602, and GB/T 603, when no other requirements are specified. The solution used in the test, if not indicated which solvent is used, refers to aqueous solution. A.2 Identification test A.2.1 Reagents and materials A.2.1.1 Sodium hydroxide (or potassium hydroxide) solution: 100 g/L. A.2.1.2 Sodium dithionite (Na2S2O4). A.2.1.3 Sulfuric acid. A.2.1.4 Hydrochloric acid solution: 1+4. A.2.1.5 Pentanol. A.2.1.6 Petroleum ether A.2.1.7 5% uranyl acetate solution. A.2.1.8 Activated carbon: iodine adsorption value ≥ 400 mg/g. A.2.2 Analysis steps A.2.2.1 Solubility Dactylopius coccus Costa is easily soluble in water. The Dactylopius coccus Costa aluminum lake, of which the main cationic component is ammonium ions (Dactylopius coccus Costa aluminum ammonium), is easily soluble in water at pH 3.0 and pH 8.5; of which the main cationic component is calcium ions (Dactylopius coccus Costa aluminum calcium), is insoluble in water at pH 3.0 and easy soluble in water at pH 8.5. A.2.2.2 Color reaction Accurately weigh 1 g of Dactylopius coccus Costa sample, accurate to 0.001 g, or 0.1 g of Dactylopius coccus Costa aluminum lake, accurate to 0.000 1 g; dissolve in 30 mL of hydrochloric acid solution and boil; cool to room temperature; then, transfer to a 1 000 mL volumetric flask; use water to fix the volume to the mark; shake well. On the spectrometer, use a 1 cm cuvette; use water to do a blank test; measure the absorbance at the maximum absorption wavelength of 494 nm. The absorbance value of the tested solution shall be between 0.650 ~ 0.750; otherwise, the sample volume needs to be adjusted separately to prepare the sample solution. A.3.5 Result calculation Calculate the mass fraction w1 of carminic acid according to Formula (A.1). Where: A – absorbance value of the sample solution; 10 – conversion coefficient; m1 – mass of the sample, in grams (g); 139 – theoretical extinction value of the 1% carminic acid solution. The test results are based on the arithmetic mean of the parallel determination results; three significant figures are reserved. The absolute difference between two independent determination results which are obtained under repeatability conditions shall not be greater than 1.0% of the arithmetic mean. A.4 Loss on drying Adopt Method I direct drying method of GB 5009.3-2016; the drying temperature and time are 135 °C ± 2 °C and 3 h respectively. A.5 Determination of dilute ammonia insoluble matter A.5.1 Reagents and materials A.5.1.1 Ammonia solution: Measure 160 mL of ammonia water; use water to dilute to 500 mL. A.5.1.2 0.1% dilute ammonia water: Measure 4 mL of nitrogen water; use water to dilute to 1 000 mL. A.5.2 Instruments and apparatuses A.6.1.4 Water: Grade-1 water that is specified in GB/T 6682. A.6.2 Instruments and apparatuses Gas chromatograph: with hydrogen flame ionization detector (FID) and headspace sampler. A.6.3 Reference chromatographic conditions A.6.3.1 Chromatographic column: fused silica; the column length is 30 m; the inner diameter is 0.53 mm; the coating is 100% dimethyl polysiloxane; the coating thickness is 5 μm. Or a chromatographic column of equivalent performance. A.6.3.2 Carrier gas: helium. A.6.3.3 Flow rate: 208 kPa, 5 mL/min. A.6.3.4 Column temperature: maintain 35 °C for 5 minutes; then, rise to 90 °C at a rate of 5 °C/min; maintain for 6 minutes. A.6.3.5 Temperature of the sample injector: 140 °C. A.6.3.6 Temperature of the detector: 300 °C. A.6.4 Reference headspace conditions A.6.4.1 Sample heating temperature: 60 °C. A.6.4.2 Sample heating time: 10 min. A.6.4.3 Injector temperature: 70 °C. A.6.4.4 Transmission temperature: 80 °C. A.6.4.5 Sample gas injection: split mode, 1.0 mL. A.6.5 Analysis steps A.6.5.1 Preparation of internal standard solution Pipette 50 mL of water into a 50 mL injection bottle; seal; accurately weigh, accurate to 0.000 1 g. Pipette 15 μL of trimethyldipentanone; inject it into the sample bottle through the membrane; mix well; weigh again, to the nearest 0.000 1 g. A.6.5.2 Preparation of blank solution ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB 1886.315-2021 be delivered?

Answer: The full copy PDF of English version of GB 1886.315-2021 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 1886.315-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB 1886.315-2021_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB 1886.315-2021 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB 1886.315-2021?

A step-by-step guide to download PDF of GB 1886.315-2021_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 1886.315-2021".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9