US$459.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. FZ/T 99006-2016: Specification for FX series of high efficiency three-phrase induction motor for textile purpose(Frame size 90~225) Status: Valid FZ/T 99006: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
FZ/T 99006-2016 | English | 459 |
Add to Cart
|
4 days [Need to translate]
|
Specification for FX series of high efficiency three-phrase induction motor for textile purpose(Frame size 90~225)
| Valid |
FZ/T 99006-2016
|
FZ/T 99006-1992 | English | RFQ |
ASK
|
5 days [Need to translate]
|
Techinical conditions of FX-series textile high-efficiency three-phase asynchronous motors (H90~225mm)
| Obsolete |
FZ/T 99006-1992
|
PDF similar to FZ/T 99006-2016
Basic data Standard ID | FZ/T 99006-2016 (FZ/T99006-2016) | Description (Translated English) | Specification for FX series of high efficiency three-phrase induction motor for textile purpose(Frame size 90~225) | Sector / Industry | Spinning & Textile Industry Standard (Recommended) | Classification of Chinese Standard | W92 | Classification of International Standard | 59.120.01 | Word Count Estimation | 20,258 | Date of Issue | 2016-10-22 | Date of Implementation | 2017-04-01 | Older Standard (superseded by this standard) | FZ/T 99006-1992 | Quoted Standard | GB/T 191-2008; GB 755-2008; GB/T 997-2008; GB/T 1032-2012; GB 1971-2006; GB/T 1993-1993; GB/T 4772.1-1999; GB/T 4942.1-2006; GB 10068-2008; GB/T 10069.1-2006; GB 14711-2013; GB/T 22719.1-2008; GB/T 22719.2-2008; FZ/T 90059-2009 | Regulation (derived from) | Ministry of Industry and Information Technology Announcement No.56 of 2016 | Issuing agency(ies) | Ministry of Industry and Information Technology of the People's Republic of China | Summary | This standard specifies the type, basic parameters and dimensions of the FX series textile high efficiency three phase asynchronous motor, the technical requirements, the inspection rules and test methods, and the requirements for marking, packing and warranty. This standard is applicable to FX series high efficiency three-phase asynchronous motor (frame number 90 ~ 225) (hereinafter referred to as "electric motor") for all kinds of textile equipment such as cotton, wool, hemp, silk and chemical fiber. The motor specified in this standard has the ability of preventing fiber clogging and high overload capacity, and is suitable for use in short fiber environment. Note: According to user requirements, made of hot and humid type of motor. |
FZ/T 99006-2016: Specification for FX series of high efficiency three-phrase induction motor for textile purpose(Frame size 90~225) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specification for FX series of high efficiency three-phrase induction motor for textile man (Frame size 90 ~ 225)
ICS 59.120.01
W92
People 's Republic of China textile industry standards
Replacing FZ/T 99006-1992
FX series of high efficiency three - phase asynchronous motor
Technical conditions (frame number 90 ~ 225)
textilepurpose (Framesize90 ~ 225)
2016-11-29 released
2017-04-01 implementation
Issued by the Ministry of Industry and Information Technology of the People 's Republic of China
Directory
Preface III
1 Scope 1
2 normative reference document 1
Type 3, basic parameters and dimensions
Technical requirements 7
5 Inspection rules and test methods 14
6 mark, packing and warranty period 15
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is for FZ/T 99006-1992 "FX series of high-efficiency three-phase asynchronous motor technology (H90 ~ 225mm)"
Revised, compared with FZ/T 99006-1992, in addition to editorial changes, the main technical changes are as follows.
--- H90 ~ 225mm in the standard name is changed to frame number 90 ~ 225;
--- increase the power of 55kW motor (see Table 1);
- increase the tolerance of the keyway and the tolerance of the mounting hole K, S position tolerance (see Table 2 to Table 5);
(Note 2 in Table 4), note 2 in Table 4) (see Note 2 in Table 5), note b,
--- to cancel the original standard "3.2.3 relative humidity" requirements;
- increase the "minimum ambient air temperature" requirement [see c in 4.2)];
--- increase the "efficiency measurement method" provisions (see 4.4);
- the increase in "tolerance of tolerance" in the tolerance of electrical performance guarantees (see 4.9);
--- Change the insulation class of machine block 132 and below from Class E to Class B (see 4.10.1);
- increased the time limit for the intermittent time in the temperature rise test (see 4.10.2);
--- increase the motor overcurrent requirements (see 4.12);
--- increase the motor safety speed requirements (see 4.13);
--- less than 1kW motor stator winding withstand voltage test test voltage from 1260V to 1760V, 1510V changed to
2110V (see 4.16);
- The peak value of the impulse voltage of the stator winding withstand voltage test is in accordance with the provisions of GB/T 22719.2-2008 (see 4.17);
- Constant stator temperature test of motor stator winding is carried out according to FZ/T 90059-2009 (see 4.18);
--- mechanical vibration of the motor according to GB 10068-2008 "shaft center height of 56mm and above the mechanical vibration of the motor vibration
Measurement, assessment and limitation "(see 4.19);
- Motor noise limits according to GB 10069.3-2008 "Rotating motor noise measurement method and limits Part 3 Noise limits
Value "(see 4.20);
The direction of rotation of the motor shall comply with the provisions of GB 1971-2006 (see 4.27);
--- requirements for increased motor safety performance (see 4.28);
- check the measurement of the increase in vibration and the direction of rotation in the test items [see i in 5.2) j)];
- check the increase in slip in the test project [see c in 5.4]];
- check the sampling method in the pilot project to be developed by the manufacturer (see 5.6);
- increase the occasional overcurrent test (see 5.7);
--- Check the inter-turn insulation test in the test item to GB/T 22719.1-2008 (see 5.8);
- increase the power factor in the item to be indicated on the nameplate [see k in 6.2]];
--- Increase the motor warranty (see 6.8).
This standard is proposed by China Textile Industry Federation.
This standard by the National Textile Machinery and Accessories Standardization Technical Committee (SAC/TC215) centralized, the national industrial machinery electrical system standard
Qualification Technical Committee Technical Committee for Textile Machinery Electrical System Subcommittee (SAC/TC231/SC1) Professional.
The main drafting unit of this standard. Qingdao and Li Da Electric Co., Ltd. is mainly responsible for, Weinan Qingfeng Technology Co., Ltd., Jiangsu Anjie Electrical
Technology Co., Ltd., Beijing in the spinning fine Electrical and Mechanical Equipment Co., Ltd., Beijing Zhong Ren Zhijie Technology Development Co., Ltd., Qingdao Hongda textile machinery
Limited liability company.
The main drafters of this standard. Zheng Yankun, Lvxin Rong, Zhang Changpin, Bi Liyun, Guo Zongyi, Shao Songjuan, Ding Hongwei.
This standard replaced the previous version of the standard release.
--- ZBK22001-1988;
--- FZ/T 99006-1992.
FX series of high efficiency three - phase asynchronous motor
Technical conditions (frame number 90 ~ 225)
1 Scope
This standard specifies the FX series of high-efficiency three-phase asynchronous motor type, the basic parameters and size, technical requirements, inspection regulations
The test method and the requirements for marking, packaging and warranty.
This standard applies to cotton, wool, linen, silk and chemical fiber and other types of textile equipment dedicated FX series of high efficiency three-phase asynchronous motor (frame number
90 to 225) (hereinafter referred to as "motor"). The motor specified in this standard has a fiber-blocking ability and a high overload capacity,
Used in short fiber environments.
Note. According to user requirements, made of hot and humid type of motor.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 191-2008 packaging and storage icon
Rotating motor quota and performance GB 755-2008
GB/T 997-2008 Rotary motor structure type, type of installation and the location of the junction box classification (IM code)
Test method for three - phase asynchronous motor GB/T 1032-2012
Rotating electrical machinery - Terminal marking and direction of rotation GB 1971-2006
Rotating motor cooling method GB/T.1993-1993
GB/T 4772.1-1999 Rotating motor dimensions and output power class - Part 1. Frame numbers 56 to 400 and flange numbers
55 ~ 1080
Protection class (IP code) classification of the overall structure of rotating electrical machines GB/T 4942.1-2006
GB 10068-2008 Measurement, evaluation and limits of mechanical vibration of a motor with a shaft center height of 56 mm or more
GB/T 10069.1-2006 Methods and limits for the determination of noise of rotating electrical machines - Part 1. Determination of noise of rotating electrical machines
General safety requirements for small and medium - sized rotating electrical machines GB 14711-2013
GB/T 22719.1-2008 Interchange insulation of alternating voltage low-voltage motors - Part 1. Test methods
GB/T 22719.2-2008 Interchange insulation of alternating voltage low-voltage motors - Part 2. Test limits
Test method for constant damp heat of textiles for textile use FZ/T 90059-2009
3 type, basic parameters and dimensions
3.1 Motor enclosure protection class IP44 (according to GB/T 4942.1-2006).
3.2 motor cooling method for the IC411 (according to GB/T.1993-1993 requirements).
3.3 The structure and installation of the motor are IMB3, IMB5, IMB35, IMV1 (according to GB/T 997-2008). user
When required, other structures and installation types can be made.
3.4 The motor quota is a continuous quota based on the continuous working system (S1).
3.5 The rated frequency of the motor is 50Hz and the rated voltage is 380V.
3.6 The motor shall be manufactured at the following rated power. 0.55kW, 0.75kW, 1.1kW, 1.3kW, 1.5kW, 1.8kW, 2.2kW,
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of FZ/T 99006-2016_English be delivered?Answer: Upon your order, we will start to translate FZ/T 99006-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of FZ/T 99006-2016_English with my colleagues?Answer: Yes. The purchased PDF of FZ/T 99006-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version FZ/T 99006-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version FZ/T 99006-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|